Ref 320.05.368Model Trinity Acetabular Shells

Trinity with no TPS 320.05.368 is an acetabular shell (EU MDD Class III; FDA Class II) made by Corin Ltd, registered in EUDAMED on 22 Sep 2026 (Basic UDI-DI B-05055343880685), cleared under FDA 510(k) K123705 on 12 Feb 2013 and listed in FDA GUDID since 17 Aug 2016 (UDI-DI 05055343880685), active as of 25 Oct 2026. 4 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

4 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K123705

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-05055343880685 Basic UDI-DI 05055343880685UDI-DIDate22 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number05055343880685 UDI-DI Date17 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK123705 Date12 Feb 2013DecidedStatusActive

Official records

From the FDA record

Device description
Trinity Non-occluded Titanium Plasma Spray Acetabular Shell Ø68mm Taper Size 5
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile; sterilise before use (Radiation Sterilization)

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-05055343880685 registered 22 Sep 2026 Active
  • FDA 510(k) K123705 decided 12 Feb 2013 Active
  • FDA GUDID UDI-DI 05055343880685 listed 17 Aug 2016 Listed

Recalls

4 recalls · FDA

    • Terminated Z-2605-2021 FDA Class II initiated 28 Jul 2021

    The packaging system on the devices have potential physical and water damage resulting in damage to the devices, loss of sterility, or contamination of the devices.

  • 3 recalls, same reason

    • Terminated Z-1526-2016 FDA Class II initiated 29 Jan 2016
    • Terminated Z-1528-2016 FDA Class II initiated 29 Jan 2016
    • Terminated Z-1527-2016 FDA Class II initiated 29 Jan 2016

    Potential for abrasion of the sterile barrier pouches of the new packaging system.

Timeline

7 dated events

  1. Cleared FDA 510(k) K123705
  2. Recall initiated FDA recalls Z-1526-2016
  3. Recall initiated FDA recalls Z-1528-2016
  4. Recall initiated FDA recalls Z-1527-2016
  5. Listed FDA GUDID 05055343880685
  6. Recall initiated FDA recalls Z-2605-2021
  7. Registered EUDAMED B-05055343880685

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Trinity Non-Occluded Ti Plasma Shell Ø68mm Taper Size 5 EUDAMED
Trinity with no TPS GUDID
Generic name
Acetabular shell
Device name
Trinity Acetabular shells for use in Trinity Acetabular System
Model / Ref / Catalog
320.05.368, Trinity Acetabular Shells
Primary DI / UDI-DI
05055343880685
Basic UDI-DI
B-05055343880685
510(k) Number
FDA product code
MEH, LZO
EMDN code
P090803010201 Primary implant uncemented metal acetabular cups
GMDN term
Acetabular shell
Device class
Class III EUDAMED
Class II GUDID
Regulation number
888.3353
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution
Sterilisation method
Radiation Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class III
GUDID
Class II
Sterilise before useEUDAMED
No
GUDID
Yes

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Sterilise before use UDI-DI 05055343880685: EUDAMED states No, FDA GUDID states Yes.

Device class is stated on each registry's own scale: Class III in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under PRIMARY IMPLANT UNCEMENTED METAL ACETABULAR CUPS.

Other devices from Corin Ltd

See all devices from Corin Ltd →

Properties

  • Supplied sterile
  • Sterilise before use NoEUDAMEDYesGUDID
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)