Trulink 90481
by Spacelabs Healthcare (Washington), Inc 5 variants
Trulink 90481 (012-0497-00) is a Class II device made by Spacelabs Healthcare (Washington), Inc, cleared under FDA 510(k) K103142 on 3 Mar 2011 and listed in FDA GUDID since 20 Dec 2016 (UDI-DI 10841522101885), active as of 23 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10841522101885 | Date20 Dec 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK103142 | Date3 Mar 2011 | StatusActive |
Official records
- AccessGUDID record 10841522101885
- FDA 510(k) database K103142
Across registries
- FDA 510(k) K103142 decided 3 Mar 2011 Active
- FDA GUDID UDI-DI 10841522101885 listed 20 Dec 2016 Listed
Recalls
-
- Ongoing Z-2245-2026
- Ongoing Z-2246-2026
- Ongoing Z-2247-2026
- Ongoing Z-2244-2026
- Ongoing Z-2243-2026
GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the CARESCAPE Central Station or CIC Pro Clinical Information Center (Central Station).
-
- Ongoing Z-2052-2026
Due to a manufacturing issue (i.e. malfunctioning of electrical Leakage tester).
-
- Ongoing Z-1793-2026
Multi-parameter command module has a circuit board issue and when in Auto mode, Cardiac Output (CO) measurement may activate early, resulting in Bad Curve error with no CO measurement or Irregular Curve error with CO measurement not automatically excluded, which may result in inaccurate readings, or the need of additional readings, which may lead to delayed care and/or fluid overload.
-
- Ongoing Z-1503-2023
Command modules will display the following when parameter processing is suspended, depending on software version: 1) Older versions will have waveforms present with no alarms, 2) Newer versions have waveforms absent with no alarms. This may cause clinicians to miss a potentially catastrophic event.
-
- Terminated Z-2343-2016
The firm has received multiple reports of the Non-Invasive Blood Pressure (NIBP) parameter becoming non-functional with an associated message (No Reading). In addition, there is one of the following three error messages: Inflate Error, HW Error, or No Data.
-
- Terminated Z-1577-2015
Modules resetting. This failure mode happens when the Spacelabs Command Module is configured with the Masimo SpO2 option (-M), the Spacelabs Respiration option (-R) and the Masimo SpO2 PCBA, PN: 010-1136-02. With these two options and the Masimo SpO2 PCBA present, the module may experience random resets.
-
- Terminated Z-1542-2015
Ultraview SL Command Modules which were upgraded with the Masimo SpO2 Option, Model 91496-M was affected. Customer reported that during the time that the module is resetting (~10 seconds), monitoring of all parameters will be suspended. Upon completion of this sequence, alarms will be reset to their default values.
-
- Terminated Z-1705-2014
A software anomaly causes temperature alarm limits to change to limits which are not physiologically possible and result in nuisance false positive alarms.
-
- Terminated Z-0690-2012
NIBP pump inside the Ultraview SL Command Module, Model 91496, became loose. The pump is suspended by the air hoses and electrical connections, but there can be enough movement to damage internal components and cause the module to fail.
-
- Terminated Z-0776-2012
One Spacelabs Medical Ultraview SL Command Module, Model 91496, was removed from customer due to software error.
Timeline
- Recall initiated FDA recalls Z-2343-2016
- Listed FDA GUDID 10841522101885
- Recall initiated FDA recalls Z-1503-2023
- Recall initiated FDA recalls Z-1793-2026
- Recall initiated FDA recalls Z-2052-2026
- Recall initiated FDA recalls Z-2245-2026
- Recall initiated FDA recalls Z-2246-2026
- Recall initiated FDA recalls Z-2247-2026
- Recall initiated FDA recalls Z-2244-2026
- Recall initiated FDA recalls Z-2243-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Trulink
- Generic name
- Electrical-only medical device connection cable, reusable
- Model / Ref / Catalog
- 90481, 012-0497-00
- Primary DI / UDI-DI
- 10841522101885
- 510(k) Number
- FDA product code
- DSI
- GMDN term
- Electrical-only medical device connection cable, reusable
- Device class
- Class II
- Regulation number
- 870.1025
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Electrical-only medical device connection cable, reusable.
- 305mm Single Action Grasper 101-48034 by Surgical Innovations Ltd.
- Guenter Bissinger Medizintechnik GmbH 80100331 by Günter Bissinger Medizintechnik GmbH
- Bipolar cable SBCD-EU/1 by Soniquence, LLC
- ENT NIM Vital NIM4CPB2 by Medtronic Xomed Inc
- 2292 by MEDTRONIC, INC.
- IntelliVue NMT Patient Cable 989803174581 by Philips Medizin Systeme Böblingen GmbH
- INVOS PMAC71RSC by Covidien LP
- 2601008 by Shanghai Dräger Medical Instrument Co., Ltd.
- TRAUS ENDO Series BAE05 by SAESHIN PRECISION CO.,LTD.
Other devices from Spacelabs Healthcare (Washington), Inc
See all devices from Spacelabs Healthcare (Washington), Inc →