# TULSA-PRO System

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/tulsa-pro-system-plp>
- Manufacturer: [Profound Medical Inc.](https://devicerts.com/manufacturers/fda-fei-3012604011) (Canada)
- Device class: Class II (US FDA)
- FDA product code: PLP

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The TULSA-Pro System is a High Intensity Focused Ultrasound (HIFU) device designed for prostate tissue ablation. It employs focused ultrasound energy to precisely target and treat benign prostatic hyperplasia (BPH) or localized prostate cancer by inducing thermal ablation without incisions or radiation.

This system is intended for use in urology and gastroenterology settings, supplied as a reusable medical device. It is not sterile upon delivery and requires appropriate preparation and maintenance as per manufacturer guidelines. The device is classified as Class II under FDA regulations and is authorized via 510(k) clearance, adhering to the Medical Device Directive (MDD) standards. Multiple registration numbers and FEI numbers are associated with its regulatory compliance.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K230692 · decision 2023-09-20 · decision SESE · status: Active
- **EUDAMED** · CE/MDD · European Union · status: Active

## Recalls

No recall on record.

## Identifiers

- 510(k) Number: K230692 [FDA 510(k)]
- FDA product code: PLP [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 876.4340 [FDA 510(k)]
- Advisory committee: Gastroenterology, Urology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: TULSA-PRO System, Profound Medical Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/tulsa-pro-system-plp (data as of 2026-11-16).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [EUDAMED](https://ec.europa.eu/tools/eudamed)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-16
- JSON: <https://devicerts.com/devices/tulsa-pro-system-plp.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/tulsa-pro-system-plp
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.