Unifocal 1 Unipolar Demand R Wave
510(k) K791955
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK791955 | Date27 Nov 1979 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DXY
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3610
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Unifocal 1 Unipolar Demand R Wave is an Implantable Pacemaker Pulse-Generator, designed to provide cardiac pacing for patients with bradycardia or conduction disorders. It operates on a unipolar demand mode, sensing the patient’s intrinsic R-wave to deliver pacing impulses only when the heart’s natural rhythm falls below a preset threshold, ensuring synchronized and efficient cardiac contraction.
This device is intended for implantable use within the cardiovascular setting and is classified as a Class III medical device under FDA regulations (21 CFR 870.3610). Supplied sterile and intended for single-use implantation, it requires proper surgical placement by a trained clinician. The device carries an FDA 510(k) clearance (K791955) and is regulated under the DXY product code, with no noted MRI safety restrictions or reusable components.
Other devices from American Pacemaker Corp.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Unifocal 1 Unipolar Demand R Wave pacemaker, and how does it differ from other pacing modes?
The Unifocal 1 Unipolar Demand R Wave pacemaker is designed to provide cardiac pacing for patients with bradycardia or conduction disorders by operating in a unipolar demand mode. Unlike fixed-rate pacemakers, it senses the patient’s intrinsic R-wave and delivers pacing impulses only when the heart’s natural rhythm falls below a preset threshold, ensuring synchronized contractions and efficient cardiac function.
Is this device intended for reuse, or is it meant for single-use implantation only?
This device is explicitly supplied sterile and intended for single-use implantation. It requires proper surgical placement by a trained clinician, and no reusable components are noted in the specifications.
What regulatory pathway was followed for FDA clearance of this device, and what product code does it fall under?
The Unifocal 1 Unipolar Demand R Wave pacemaker received FDA clearance through a traditional 510(k) pathway, classified as substantially equivalent (SESE). It is regulated under the product code DXY and falls under the Cardiovascular medical specialty, with no noted MRI safety restrictions.
How long has this device been cleared by the FDA, and what was the original submission date?
The device was originally submitted to the FDA on October 1, 1979, and received clearance on November 27, 1979, making it one of the earliest pacemaker models cleared under the 510(k) pathway. Its clearance (K791955) remains active for use in implantable cardiac pacing.
What type of surgical expertise is required for implantation of this device?
This device is designed for implantable use within the cardiovascular setting and requires proper surgical placement by a trained clinician, likely a cardiologist or cardiac surgeon, due to its invasive nature and specialized pacing function.