Unity VCS (8065000296); Unity CS (8065000297)
510(k) K233876Ref 8065753174
Active
Valid until
Not listed
FDA recalls
2 ongoingTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number038065GMN000073H6 00380657531745 | Date26 Mar 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00380657531745 | Date8 Apr 2025 | StatusListed |
| United States | FDA 510(k)SESE 510(k) | NumberK233876 | Date21 Jun 2024 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
-
- Ongoing Z-0305-2026
- Ongoing Z-0304-2026
Due to incomplete seals in the pouch which provide the sterile barrier.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Unity
- Generic Name
- Vitrectomy system micro-cutting unit
- Device Name
- Vitrectomy Probes
- Model / Ref / Catalog
- 8065753174, 00380657531745
- Primary DI / UDI-DI
- 00380657531745
- Basic UDI-DI
- 038065GMN000073H6
- 510(k) Number
- FDA Product Code
- HQC 510(k)MLZ GUDID
- EMDN Code
- Z1212020785 Phaco-vitrectomy instruments - consumables
- GMDN Term
- Vitrectomy system micro-cutting unit
- Models / Variants
- Device Class
- Class IIb EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 886.4670 510(k)886.4150 GUDID
- EU market of registration
- Belgium
- Advisory Committee
- Ophthalmic
- FDA Decision
- SESE Substantially Equivalent
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| Model / Reference | 8065753174 | — | 00380657531745 |
| FDA Product Code | — | HQC | MLZ |
| Device Class | Class IIb | Class II | Class II |
| Regulation Number | — | 886.4670 | 886.4150 |
Overview
AI-generated summary, 18 Sep 2026
The Unity VCS (8065000296) and Unity CS (8065000297) are phacofragmentation systems designed for ophthalmic surgical procedures. These devices facilitate cataract removal by emulsifying and aspirating the lens through ultrasonic or laser-based fragmentation, enabling precise and efficient lens extraction during phacoemulsification.
These systems are intended for use in sterile operating room environments and are classified as Class II medical devices under 21 CFR 886.4670. Both models are reusable and comply with FDA 510(k) and MDR regulatory requirements. The Unity VCS incorporates laser functionality, while the Unity CS is a traditional phacoemulsification system, each serving distinct yet complementary roles in cataract surgery.
Other devices from Alcon Laboratories, Inc.
Questions
AI-generated answers, 18 Sep 2026
What are the key differences between the Unity VCS and Unity CS systems in cataract surgery?
The Unity VCS and Unity CS are both phacofragmentation systems for cataract removal, but they differ in their core technology. The Unity VCS uses laser-based fragmentation, which provides precise, energy-controlled emulsification of the lens. In contrast, the Unity CS relies on traditional ultrasonic phacoemulsification, a well-established method for breaking down the cataract. Both systems are designed for sterile operating room use and are reusable, but the VCS’s laser capability offers an alternative approach for surgeons who prefer laser-assisted techniques.
Are these devices single-use or reusable, and what does that mean for my practice’s workflow?
The Unity VCS and Unity CS systems are reusable, meaning they are designed for repeated use after proper cleaning, disinfection, and maintenance. This makes them cost-effective for high-volume practices, as they eliminate the need for disposable alternatives. However, reuse requires adherence to strict sterilization protocols to ensure patient safety and device performance. Your practice will need to integrate these systems into your existing reprocessing workflow.
What regulatory pathways have these devices undergone, and how does that affect their use in clinical settings?
Both the Unity VCS and Unity CS have undergone FDA 510(k) clearance and comply with EU MDR (Medical Device Regulation) requirements, confirming their substantial equivalence to predicate devices. This means they meet U.S. and EU safety and performance standards for phacofragmentation systems. Clinicians can rely on these clearances as evidence of rigorous evaluation, though local regulations (e.g., hospital purchasing policies or country-specific requirements) may still apply before use.
How are these systems supplied, and do they require any special handling or storage conditions?
While the exact packaging details aren’t specified, as reusable Class II devices, the Unity VCS and Unity CS are likely supplied in sterile or clean, non-sterile packaging for initial use or reprocessing. Since they’re reusable, proper storage involves keeping them in a clean, dry environment (e.g., dedicated carts or cabinets) to prevent contamination between uses. Sterilization (e.g., autoclave or chemical sterilization) will be required before each procedure, following manufacturer guidelines to maintain functionality and safety.
Properties
Other properties (17)
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No