Us2.v2
Us2.v2 is a medical device (FDA Class II; FDA product code QIH, Automated Radiological Image Processing Software) made by Eko.ai Pte. Ltd., cleared under FDA 510(k) K233676 on 1 Apr 2024 and listed in FDA GUDID since 22 Apr 2024 (UDI-DI 00860005876815), active as of 22 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00860005876815 | Date22 Apr 2024 | StatusListed |
| United States | FDA 510(k)SESE | NumberK233676 | Date1 Apr 2024 | StatusActive |
Official records
- AccessGUDID record 00860005876815
- FDA 510(k) database K233676
From the FDA record
- Device description
- Us2.v2 software is used to process acquired transthoracic cardiac ultrasound images, to analyze and make measurements on images in order to provide automated estimation of several cardiac structural and functional parameters, including left/ right atrial and ventricular linear dimensions, volumes, systolic function and diastolic function, measured by B mode, M mode and Doppler (PW, CW, tissue) modalities. The data produced by this software is intended to be used to support qualified cardiologists, sonographers, or other licensed professional healthcare practitioners for clinical decision-making. Us2.v2 is indicated for use in adult patients. Please note the following limitations: • Poor image capture will lead to poor annotations and subsequent measurements. Multiple image quality algorithms are used to filter out images of poor quality. • Our software complements good patient care and does not exempt the user from the responsibility to provide supervision, clinically review the patient, and make appropriate clinical decisions. • If no gender is present, female referenced guideline values will be used for conclusions. • If Body Surface Area (BSA) is not present, indexed values cannot be provided. • During image acquisition, inappropriate use of the echo machine, use of non-cardiac ultrasound probes, use of suboptimal settings (e.g. gain, contrast, depth), or lack of electrocardiogram capture may lead to lower accuracy of the software.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K233676 decided 1 Apr 2024 Active
- FDA GUDID UDI-DI 00860005876815 listed 22 Apr 2024 Listed
Timeline
- Cleared FDA 510(k) K233676
- Listed FDA GUDID 00860005876815
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Radiology DICOM image processing application software
- Model / reference
- 2
- Primary DI / UDI-DI
- 00860005876815
- FDA product code
- QIH
- GMDN term
- Radiology DICOM image processing application software
- Device class
- Class II
- Regulation number
- 892.2050
- GUDID distribution status
- In Commercial Distribution
Similar devices in this category
Other devices filed under Radiology DICOM image processing application software.
- Veolity 1.7 by MeVis Medical Solutions AG
- BriefCase-Quantification (BC-QTF) by AIDOC MEDICAL LTD
- HipMap Femoroacetabular Impingement Analysis 3105001000 by Stryker Corp.
- 3mensio Workstation 10.7 by Pie Medical Imaging B.V.
- CAAS MR Solutions 5.3 by Pie Medical Imaging B.V.
- Advanced Visualization Workspace 881120 by Philips Medical Systems Nederland B.V.
- icobrain ctp 1 by icometrix NV
- RConsole1 1.0 by Drtech Corp.
- Quantra 2.2 R2LIC-2103-V2.2 by Hologic
- Corridor4DM C4DM10 by Invia