V2 Injection Site
510(k) K955585
V2 Injection Site is a medical device (FDA Class II; FDA product code FPA, Set, Administration, Intravascular) made by B. Braun Medical, Inc., cleared under FDA 510(k) K955585 on 15 May 1996, active as of 8 Nov 2026. 25 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK955585 | Date15 May 1996 | StatusActive |
Official records
- FDA 510(k) database K955585
From the FDA record
- Received by the FDA
- 7 Dec 1995
- FDA decision
- 15 May 1996 (Substantially Equivalent)
- FDA review time
- 160 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Ongoing Z-0714-2026
Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
-
- Ongoing Z-0090-2023
The extension set has a high probability of failure which could lead to possible leakage or detachment at the device's bonded joint during use. The issue may result in delay of therapy, increased risk of bloodstream infections (BSI), and may expose both patients and healthcare workers to hazardous medications. Depending on the nature of the leak and type of infusion, there is also the potential for life-threatening situations to occur including air embolization or hypovolemia.
-
- Terminated Z-0987-2014
Complaints were received reporting leakage on certain lots of SAFSITE Injection Sites and IV Sets manufactured with SAFSITE Injection Sites.The SAFSITE Injection Site is intended to provide needle free access on IV and Extension Sets.
-
- Terminated Z-2166-2013
Reports were received of an incorrectly assembled Outlook Safety Infusion System Burette Set (Product Code 375038), and the investigation determined that one of the ULTRASITE injection sites and corresponding low pressure backcheck valve was assembled upside down.
-
- Terminated Z-0678-2010
- Terminated Z-0684-2010
- Terminated Z-0685-2010
- Terminated Z-0686-2010
- Terminated Z-0706-2010
- Terminated Z-0707-2010
- Terminated Z-0708-2010
System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
-
- Terminated Z-1427-2009
- Terminated Z-1428-2009
- Terminated Z-1429-2009
- Terminated Z-1430-2009
- Terminated Z-1431-2009
- Terminated Z-1432-2009
- Terminated Z-1433-2009
Device defect is occlusion/no flow.
-
- Terminated Z-0199-2009
Product was assembled incorrectly and connected to the wrong part.
-
- Terminated Z-2407-2008
- Terminated Z-2410-2008
- Terminated Z-2411-2008
- Terminated Z-2412-2008
- Terminated Z-2413-2008
incorrect burette was packaged with the product
-
- Terminated Z-0818-2007
- Terminated Z-0819-2007
Secondary infusion backs up into primary container.
-
- Terminated Z-0933-03
possible leakage
Timeline
- Recall initiated FDA recalls Z-0684-2010
- Recall initiated FDA recalls Z-0685-2010
- Recall initiated FDA recalls Z-0686-2010
- Recall initiated FDA recalls Z-0706-2010
- Recall initiated FDA recalls Z-0707-2010
- Recall initiated FDA recalls Z-0708-2010
- Recall initiated FDA recalls Z-2166-2013
- Recall initiated FDA recalls Z-0987-2014
- Recall initiated FDA recalls Z-0090-2023
- Recall initiated FDA recalls Z-0714-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- FPA
- FDA applicant
- B.Braun Medical, Inc.
- Device class
- Class II
- Regulation
- 21 CFR Part 880.5440
- Advisory committee
- General Hospital
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code FPA (Set, Administration, Intravascular).
- IV START KIT by Medikmark, Inc.
- IV ADMINISTRATION SETS WITH NEEDLELESS ACCESS DEVICES by Venetec, Inc.
- FIXED FLOW RATE GRAVITY ADMINISTRATION SETS by I-Flow Corp.
- COOK HIGH VOLUME INFUSION ADAPTER INTRAVASCULAR ADMINISTRATION SET by Cook, Inc.
- SURSHIELD SAFETY WINGED BLOOD COLLECTION SET by TERUMO MEDICAL CORPORATION
- SET, ADMINISTRATION INTRAVASCULAR by Kendall Mcgaw Laboratories, Inc.
- ISOFLUX IXZ FLOW REGULATOR by Ferguson Medical
- OPTFlow OPT12614 by EMED Technologies Corporation
- HIGH PRESSURE SETS-400 PSI by ICU MEDICAL, INC.
- FLUID ADMINISTRATIVE SET, AFI by Linton Biomed Corp.