# V2 Injection Site

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/v2-injection-site-fpa>
- Manufacturer: [B. Braun Medical, Inc.](https://devicerts.com/manufacturers/b-braun-medical-inc) (United States, FDA 510(k) applicant)
- Name in the registry: V2 INJECTION SITE
- Device class: Class II (US FDA)
- FDA product code: FPA

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K955585 · decision 1996-05-15 · decision SESE · status: Active

## Recalls

- Z-0714-2026 · Class II · ongoing · initiated 2025-10-29: Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion).
- Z-0090-2023 · Class II · ongoing · initiated 2022-09-15: The extension set has a high probability of failure which could lead to possible leakage or detachment at the device's bonded joint during use. The issue may result in delay of therapy, increased risk of bloodstream infections (BSI), and may expose both patients and healthcare workers to hazardous medications. Depending on the nature of the leak and type of infusion, there is also the potential for life-threatening situations to occur including air embolization or hypovolemia.
- Z-0987-2014 · Class II · terminated · initiated 2014-01-08: Complaints were received reporting leakage on certain lots of SAFSITE Injection Sites and IV Sets manufactured with SAFSITE Injection Sites.The SAFSITE Injection Site is intended to provide needle free access on IV and Extension Sets.
- Z-2166-2013 · Class II · terminated · initiated 2013-08-05 · matched through shared submission K955585, may concern other models: Reports were received of an incorrectly assembled Outlook Safety Infusion System Burette Set (Product Code 375038), and the investigation determined that one of the ULTRASITE injection sites and corresponding low pressure backcheck valve was assembled upside down.
- Z-0678-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0684-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0685-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0686-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0706-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0707-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-0708-2010 ·  · terminated · initiated 2009-11-24: System error 9 alarms. A System Error 9 alarm indicates a potential pressure loss in the pump cassette delivery chamber (chamber closest to the patient). This alarm is generated during the pumps initiation sequence and will not allow the set to be used. This requires a new set to be obtained, thus creating a potential for delay in therapy.
- Z-1427-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1428-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1429-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1430-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1431-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1432-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-1433-2009 ·  · terminated · initiated 2009-03-27: Device defect is occlusion/no flow.
- Z-0199-2009 ·  · terminated · initiated 2008-09-17: Product was assembled incorrectly and connected to the wrong part.
- Z-2407-2008 ·  · terminated · initiated 2008-06-30 · matched through shared submission K955585, may concern other models: incorrect burette was packaged with the product
- Z-2410-2008 ·  · terminated · initiated 2008-06-30: incorrect burette was packaged with the product
- Z-2411-2008 ·  · terminated · initiated 2008-06-30: incorrect burette was packaged with the product
- Z-2412-2008 ·  · terminated · initiated 2008-06-30: incorrect burette was packaged with the product
- Z-2413-2008 ·  · terminated · initiated 2008-06-30: incorrect burette was packaged with the product
- Z-0818-2007 ·  · terminated · initiated 2007-04-18: Secondary infusion backs up into primary container.
- Z-0819-2007 ·  · terminated · initiated 2007-04-18: Secondary infusion backs up into primary container.
- Z-0933-03 ·  · terminated · initiated 2003-04-14: possible leakage

## Identifiers

- 510(k) Number: K955585 [FDA 510(k)]
- FDA product code: FPA [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 880.5440 [FDA 510(k)]
- Advisory committee: General Hospital [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: V2 Injection Site, B. Braun Medical, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/v2-injection-site-fpa (data as of 2026-11-24).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-08
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/v2-injection-site-fpa.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/v2-injection-site-fpa
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.