Valleylab FT10 Electrosurgical Platform, Cardioblate BP2 Surgical Ablation Device, Cardioblate LP Surgical Ablation Device
by Medtronic
510(k) K182610
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK182610 | Date19 Dec 2018 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- OCL
- Device Class
- Class II
- Regulation
- 21 CFR Part 878.4400
- Advisory Committee
- General, Plastic Surgery
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Valleylab FT10 Electrosurgical Platform is a Class II surgical device that provides high‑frequency radiofrequency energy for cutting, coagulation, and ablation of tissue, including cardiac tissue. It functions as a generator for monopolar and bipolar procedures and is intended to drive a range of energy‑based instruments in the operating room.
The platform is used with the single‑use Cardioblate BP2 and Cardioblate LP surgical ablation devices, which are bipolar RF ablation tools that incorporate saline irrigation to cool tissue during energy delivery. It is supplied as a reusable generator system for hospital use, received FDA 510(k) clearance (decision date 2018‑12‑19), and is classified under product code OCL for surgical devices.
Other devices from Medtronic, Inc.
Questions
AI-generated answers, 1 Oct 2026
What types of procedures can the Valleylab FT10 platform support?
The FT10 provides high‑frequency radiofrequency energy for cutting, coagulation, and ablation, including both monopolar and bipolar modes. This enables it to be used in general surgical, plastic surgery, and cardiac ablation procedures where precise tissue removal or lesion creation is required.
Are the Cardioblate BP2 and LP ablation devices reusable or single‑use?
Both the Cardioblate BP2 and Cardioblate LP are supplied as single‑use, disposable bipolar RF ablation tools. They incorporate saline irrigation to cool tissue during energy delivery, and each unit is intended for one procedure only to maintain sterility and performance.
How is the FT10 system supplied and maintained in a hospital setting?
The FT10 is provided as a reusable generator system that remains in the operating room for repeated use. It is designed for hospital use, requiring routine cleaning and maintenance according to the manufacturer’s instructions, while the associated ablation handpieces are discarded after each case.
What regulatory pathway did the FT10 follow for market entry?
The device received FDA 510(k) clearance on December 19, 2018, classified as a Class II surgical device under product code OCL. The clearance was based on a determination of substantial equivalence to a predicate device, following the traditional 510(k) submission process.