Vanguard Reprocessed Compression Garment
by Vanguard Medical Concepts, Inc.
510(k) K012403
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK012403 | Date17 Oct 2001 | StatusActive |
Recalls
-
- Terminated Z-0272-2018
3040 compression sleeves being mislabeled as a 3010-PL compression sleeves.
-
- Terminated Z-1661-2008
- Terminated Z-1672-2008
- Terminated Z-1671-2008
- Terminated Z-1676-2008
- Terminated Z-1666-2008
Sterility Compromised -- Ascent Healthcare Solutions cannot validate the sterilization process for a variety of Ascent Healthcare Solutions products.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- JOW
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.5800
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Vanguard Reprocessed Compression Garment is classified as a Sleeve, Limb, Compressible device, designed to apply graduated pressure to patient extremities. It functions as part of an external air compression system, where inflatable bladders within the garment create pressure to prevent blood pooling and enhance venous return, primarily in cardiovascular applications. The device is intended for use with external air compression pumps to deliver therapeutic compression therapy.
This garment is supplied as a reprocessed, single-use item following cleaning, inspection, testing, and ethylene oxide sterilization by the manufacturer. It is intended for clinical use by healthcare staff in settings such as hospitals or outpatient facilities. The device is classified under FDA regulation 870.5800 and holds a 510(k) clearance (K012403) with a product code of JOW. Multiple registration numbers and FEI numbers are associated with its distribution.
Other devices from Vanguard Medical Concepts, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Vanguard Reprocessed Compression Garment used for?
The Vanguard Reprocessed Compression Garment is designed as a sleeve for limb compression, intended to be used with external air compression pumps. It applies graduated pressure to patient extremities to prevent blood pooling and improve venous return, primarily in cardiovascular therapy settings. The inflatable bladders within the garment create the necessary compression when paired with a compatible pump.
How is the Vanguard Reprocessed Compression Garment supplied and prepared for use?
This device is supplied as a reprocessed, single-use item. It undergoes cleaning, inspection, testing, and ethylene oxide sterilization by the manufacturer before distribution. Each garment is intended for one-time clinical use by healthcare staff in hospitals or outpatient facilities, ensuring sterility and safety for patient application.
Is the Vanguard Reprocessed Compression Garment sterile and reusable?
No, the Vanguard Reprocessed Compression Garment is not reusable. It is supplied as a single-use item after undergoing ethylene oxide sterilization during reprocessing. This ensures sterility and compliance with clinical standards for patient safety.
What sizes or models are available for the Vanguard Reprocessed Compression Garment?
The device is categorized under FDA product code JOW and is classified as a *Sleeve, Limb, Compressible* device. While specific size variations (e.g., pediatric, adult, or custom-fit models) are not detailed in the provided data, the garment is designed to fit standard limb sizes for external air compression therapy. For precise sizing, refer to manufacturer specifications or consult clinical guidelines.
How should the Vanguard Reprocessed Compression Garment be stored?
The reprocessed garment should be stored in its original, sealed packaging to maintain sterility until use. After opening, it must be used immediately as a single-use item. Storage conditions should comply with manufacturer guidelines to prevent contamination or degradation, typically in a clean, dry environment away from direct sunlight or extreme temperatures.