Vapr
510(k) K974022
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK974022 | Date12 Jan 1998 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- GEI
- Device Class
- Class II
- Regulation
- 21 CFR Part 878.4400
- Advisory Committee
- General, Plastic Surgery
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The VAPR Radiofrequency Electrode System is a bipolar electrosurgical device designed for arthroscopic procedures. It performs soft tissue ablation, contouring, cutting, and hemostasis through controlled radiofrequency energy application. This system is categorized under general plastic surgery devices and is intended for use in minimally invasive joint surgeries.
The device is supplied as a reusable system with disposable electrode probes, including models such as VAPR S90, VAPR LD, VAPR LP, VAPR Premiere50, VAPR 90 Degree, VAPR S50, and VAPR Premiere90. It operates under FDA 510(k) clearance (K974022) and is intended for use in sterile environments within operating rooms. Storage and handling must comply with manufacturer guidelines to ensure proper functionality and safety.
Other devices from Mitek Products
Questions
AI-generated answers, 1 Oct 2026
What is the VAPR Radiofrequency Electrode System used for?
The VAPR Radiofrequency Electrode System is designed specifically for arthroscopic surgeries, where it delivers controlled radiofrequency energy to perform soft tissue ablation, contouring, cutting, and hemostasis. This makes it ideal for minimally invasive joint procedures where precision and reduced trauma are critical.
How is the VAPR system supplied, and what models are available?
The VAPR system is supplied as a reusable unit, paired with disposable electrode probes. Available models include the VAPR S90, VAPR LD, VAPR LP, VAPR Premiere50, VAPR 90 Degree, VAPR S50, and VAPR Premiere90, each tailored for specific surgical applications.
Is the VAPR system single-use or reusable?
The VAPR system itself is reusable, but it requires the use of disposable electrode probes for each procedure. This design ensures sterility and reduces cross-contamination risks in sterile operating room environments.
Where and how should the VAPR system be stored?
The VAPR system must be stored in accordance with the manufacturer’s guidelines to maintain functionality and safety. Since it is intended for sterile environments, storage should be in a clean, dry location away from direct sunlight or extreme temperatures. Disposable probes should be stored in their original packaging until use.
What regulatory clearance does the VAPR system hold?
The VAPR Radiofrequency Electrode System holds FDA 510(k) clearance under the classification of general plastic surgery devices, with a clearance number of K974022. This clearance confirms its substantial equivalence to a predicate device and compliance with U.S. regulatory standards.