Skip to content

Vaprox PB028

by Steris Corporation

Vaprox PB028, a hydrogen peroxide device sterilant (FDA Class II; FDA product code MLR, Sterilizer, chemical) made by Steris Corporation, was cleared under FDA 510(k) K233065 on 20 Oct 2023 (19 earlier submissions) and listed in FDA GUDID on 8 Sep 2016 (UDI-DI 00724995089511); the registry lists it as not in commercial distribution (GUDID) as of 22 Oct 2026. FDA recalls on record: 3.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK233065 Date20 Oct 2023DecidedStatusActive
United StatesGUDID listing Number00724995089511 UDI-DI Date8 Sep 2016ListedStatusListed GUDID: not in commercial distribution

Official records

From the FDA record

Device description
The VAPROX HC Sterilant uses 59 percent Hydrogen Peroxide that is used with V-PRO Low Temperature Sterilization Systems. The net contents are 29.6 mL per cup.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K233065 decided 20 Oct 2023 Active· +19 more in the status table
  • FDA GUDID UDI-DI 00724995089511 listed 8 Sep 2016 Listed

Recalls

3 recalls · FDA

    • Terminated Z-2959-2018 FDA Class II initiated 26 Jul 2018

    There is the potential for a scenario where a punctured cup of sterilant expires while the system is powered down, upon power-up the unit will not detect the expired cup of sterilant; allowing for subsequent cycles to be run.

    • Terminated Z-0772-2018 FDA Class II initiated 28 Sep 2017

    Correction to update sterilizer software to prohibit the use of expired sterilant prior to the start of a sterilization cycle.

    • Terminated Z-3041-2011 FDA Unclassified (pre-2012) initiated 1 Aug 2011

    STERIS learned that Amsco V-PRO 1 and V-PRO 1 Plus Low Temperature Sterilization Systems users may experience premature wear of the vacuum pump and filtering assembly components. Users may also experience incomplete aeration of the device's chamber following a failed leak test.

Timeline

24 dated events

  1. Recall initiated FDA recalls Z-0772-2018
  2. Cleared FDA 510(k) K172319
  3. Cleared FDA 510(k) K172754
  4. Recall initiated FDA recalls Z-2959-2018
  5. Cleared FDA 510(k) K182568
  6. Cleared FDA 510(k) K190103
  7. Cleared FDA 510(k) K190917
  8. Cleared FDA 510(k) K222093
  9. Cleared FDA 510(k) K223476
  10. Cleared FDA 510(k) K233065

14 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Vaprox
Generic name
Hydrogen peroxide device sterilant
Model / Ref / Catalog
PB028
Primary DI / UDI-DI
00724995089511
FDA product code
MLR
GMDN term
Hydrogen peroxide device sterilant
Device class
Class II
Regulation number
880.6860
GUDID distribution status
Not in Commercial Distribution

Similar devices

Other devices filed under FDA product code MLR (Sterilizer, chemical).

Other devices from Steris Corporation

See all devices from Steris Corporation →

Properties

  • Single use
  • Over-the-counter
  • Lot / batch number
  • Expiration date
Other properties (11, all answered No)