510(k) K042513

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK042513 Date10 Feb 2005ClearedStatusActive

Official records

From the FDA record

Received by the FDA
15 Sep 2004
FDA decision
10 Feb 2005 (Substantially Equivalent)
FDA review time
148 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K042513 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
HAW
Device class
Class II
Regulation
21 CFR Part 882.4560
Advisory committee
Neurology
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The VectorVision Osteotomy is a Computer-Assisted Surgery System for orthopaedic osteotomy procedures, specifically designed to facilitate three-dimensional surgical planning and navigation of lower limb bone corrections. It integrates passive marker tracking with a patient-specific 3D bone model, enabling precise intraoperative localization and guidance during minimally invasive osteotomies. The system aligns a tracked surgical instrument with virtual anatomical landmarks, enhancing accuracy and reproducibility in bone resection and alignment. Its primary function is to assist surgeons in achieving targeted corrections while minimizing invasiveness and improving procedural outcomes.

This device is supplied as part of the VectorVision System, which includes software, hardware for marker tracking, and a user interface for navigation. It is intended for single-use or reusable components (as defined by the manufacturer’s maintenance protocols) and operates in electromagnetic interference (EMI)-controlled environments, though MRI safety data is not specified. The system requires pre-operative imaging and landmark acquisition to generate a patient-specific model, with surgical navigation conducted in the operating room. Authorized for use in the United States under FDA 510(k) clearance (K042513), the device adheres to regulatory standards for computer-assisted orthopaedic systems.

Similar devices

Other devices filed under FDA product code HAW (Neurological Stereotaxic Instrument).

Other devices from Brainlab AG

  • Automatic Registration

    Class II
  • RT Elements (4.0)

    Class II
  • ENT Em

    Class II
  • Z-Touch

    Class II

See all devices from Brainlab AG →