Identity
- Trade Name
- VenteraPointer FDA UDI
- Generic Name
- Multi-purpose stereotactic surgery system FDA UDI
- Device Name
- The product VenteraPointer is a variant of a navigated probe for image guided surgical procedures with the Ventera® Cannulated Articulating Delivery Instrument. The instrument is intended as an aid for precisely locating anatomical structures in either open or percutaneous procedures. It is indicated for use with the Fiagon Navigation system using electromagnetic navigation. The instrument is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure in the field of ENT surgery can be identified relative to a CT or MR based model of the anatomy. FDA UDI
- Model / Reference
- 1 FDA UDI
- Description
- The product VenteraPointer is a variant of a navigated probe for image guided surgical procedures with the Ventera® Cannulated Articulating Delivery Instrument. The instrument is intended as an aid for precisely locating anatomical structures in either open or percutaneous procedures. It is indicated for use with the Fiagon Navigation system using electromagnetic navigation. The instrument is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure in the field of ENT surgery can be identified relative to a CT or MR based model of the anatomy. FDA UDI
Identifiers
- Primary DI / UDI-DI
- EFIAE0129101 FDA UDI
- 510(k) Number
- K141456 FDA UDI
- FDA Product Code
- PGW FDA UDI
- GMDN Term
- Multi-purpose stereotactic surgery system FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 882.4560 FDA UDI
- Commercial Distribution
- Not in Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Moist Heat or Steam Sterilization FDA UDI
MR Unsafe FDA UDI
VenteraPointer by Fiagon GmbH — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Fiagon GmbH
Sources (1)
- FDA UDI c6934da8-6429-4b3c-8bd1-a91b6b02a73d 37 fields · synced May 30, 2026