# Vercise™ Cartesia™ DB-2202-30

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/vercise-cartesia-db-2202-30>
- Manufacturer: [Boston Scientific Neuromodulation](https://devicerts.com/manufacturers/boston-scientific-neuromodulation) (United States)
- Device class: Class III (US FDA)
- FDA product code: NHL, PJS, MHY
- GMDN: Deep brain electrical stimulation system (37307)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 08714729905271 · listed 2019-01-20 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA PMA · United States · P150031 · decision 2017-12-08 · decision APPR · status: Active · from GUDID

## Recalls

- Z-2340-2025 · Class II · ongoing · initiated 2025-07-08: Resistance and difficulties could occur while closing the retaining clip locking mechanism, which is part of a burr hole cover kit, which is part of a Deep Brain Stimulation (DBS) system, which may lead to procedural delay, or lead-migration-which may require additional surgery.
- Z-2558-2025 · Class II · ongoing · initiated 2025-07-08: Wire break(s) have occurred in rechargeable deep brain stimulation implantable pulse generators, implanted in the submuscular pectoral location. Wire breaks prevent successful stimulation, thus requiring device removal/replacement and users may experience high monopolar impedances, undesired sensation, loss of therapy, return of symptoms and/or Bluetooth connectivity challenges.
- Z-1890-2024 · Class II · ongoing · initiated 2024-04-18: Deep Brain Stimulation (DBS) Implantable Pulse Generator (IPG) may experience routine system check during IPG charging, which may cause device reset. The device reset could lead transient loss of stimulation; patients may experience undesired sensations, transient worsening of movement disorder symptoms, which may lead patient to request surgical intervention for replacement or revision.
- Z-2125-2020 · Class II · terminated · initiated 2019-04-24: The firm is initiating a voluntary removal of certain spinal cord stimulation leads, lead extensions, adapters, and deep brain stimulation lead extensions due to the "use by date" displayed on the label which is later than the correct "use by date". No adverse health consequence is expected to occur from this issue.

## Identity

- Trade name: Vercise™ Cartesia™ [FDA GUDID (AccessGUDID)]
- Generic name: Deep brain electrical stimulation system [FDA GUDID (AccessGUDID)]
- Model / reference: DB-2202-30 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 08714729905271 [FDA GUDID (AccessGUDID)]
- PMA number: P150031 [FDA GUDID (AccessGUDID)]
- FDA product code: NHL [FDA GUDID (AccessGUDID)]; PJS [FDA GUDID (AccessGUDID)]; MHY [FDA GUDID (AccessGUDID)]
- GMDN term: Deep brain electrical stimulation system (37307) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class III [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Conditional [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Vercise™ Cartesia™ DB-2202-30, Boston Scientific Neuromodulation. deviCERTS medical device catalogue. https://devicerts.com/devices/vercise-cartesia-db-2202-30 (data as of 2026-11-24).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/vercise-cartesia-db-2202-30.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/vercise-cartesia-db-2202-30
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.