Skip to content

Versatrax Model 7000 Universal A-V Pulse Generator

by Medtronic Cardiac Rhythm Disease Management

PMA P820003

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

PMA P820003↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPPR Approved 1 supplement NumberP820003 Date17 May 1985ApprovedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Generic Name
Implantable pulse generator, pacemaker (non-CRT)
PMA Number
FDA Product Code
LWP
Device Class
Class III
Advisory Committee
Cardiovascular
FDA Decision
APPR Approved
PMA Supplement
S019

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Versatrax Model 7000 is an Implantable Pulse Generator, Pacemaker (Non-CRT), designed to deliver electrical stimulation for cardiac rhythm management. It functions as an autonomous device to regulate heart rate by generating timed electrical impulses to the heart muscle, ensuring proper atrial-ventricular (A-V) sequencing in patients with bradycardia or conduction disorders.

This device is intended for implantable use and is classified as a Class III medical device under FDA regulations. Authorized under FDA_PMA (P820003), it is supplied sterile and intended for single-patient use. The Model 7000 is compatible with MRI environments under specific conditions, as outlined in its labeling, and is distributed in various sizes and configurations as referenced by its registration numbers. Storage and handling follow standard sterile implantable device protocols.

Other devices from Medtronic Cardiac Rhythm Disease Management

See all devices from Medtronic Cardiac Rhythm Disease Management →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical condition is the Versatrax Model 7000 designed to address, and how does it work?

    The Versatrax Model 7000 is designed to manage **bradycardia** (slow heart rate) and **conduction disorders**, where the heart’s electrical signals are improperly timed or absent. It functions as an **implantable pacemaker** by delivering timed electrical impulses to the heart muscle, ensuring proper **atrial-ventricular (A-V) sequencing** to maintain a regular heartbeat. This autonomous device compensates for the heart’s inability to regulate its own rhythm independently.

  • Is the Versatrax Model 7000 intended for reuse, or is it single-use only?

    The Versatrax Model 7000 is **intended for single-patient use only**, as explicitly stated in its labeling. This aligns with standard practices for implantable devices to ensure sterility and patient safety, preventing cross-contamination or device degradation from repeated use.

  • How many different sizes or configurations are available for the Versatrax Model 7000, and how are they identified?

    The Versatrax Model 7000 is available in **multiple sizes and configurations**, each identified by unique **registration numbers** (e.g., 1721676, 2017865, etc.). These variations likely accommodate different patient anatomies or clinical needs, though specific dimensions or features are not detailed in the provided data. The device’s compatibility with MRI environments is also noted in its labeling for certain models.

  • What storage and handling precautions should be taken for the Versatrax Model 7000 before implantation?

    The Versatrax Model 7000 is supplied **sterile**, so it must be stored and handled according to **standard sterile implantable device protocols** to maintain integrity until use. This includes protecting it from contamination, moisture, or physical damage, as well as adhering to manufacturer guidelines for shelf life and environmental conditions (e.g., temperature, humidity). Always refer to the included labeling for precise storage instructions.

  • What regulatory pathway was followed for the Versatrax Model 7000, and when was it authorized?

    The Versatrax Model 7000 was authorized through the **FDA’s Premarket Approval (PMA) process**, with the primary application (PMA #P820003) received on **December 24, 1985**, and approved on **March 27, 1986**. This pathway is used for high-risk, Class III devices like implantable pulse generators. The device is also associated with **supplement S025**, indicating potential updates or modifications to the original approval.