Vidas® 3 412590
Ref 412590
Vidas® 3 412590 is a device classified as Class A in the EU and Class I in the US made by Biomerieux SA, registered in EUDAMED on 10 Sep 2026 (Basic UDI-DI 357302BUDI000299TZ), cleared under FDA 510(k) K141133 on 9 Jul 2015 and listed in FDA GUDID since 14 Sep 2016 (UDI-DI 03573026380175), active as of 12 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number357302BUDI000299TZ 03573026380175 | Date10 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number03573026380175 | Date14 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK141133 | Date9 Jul 2015 | StatusActive |
Official records
- EUDAMED public site 357302BUDI000299TZ
- AccessGUDID record 03573026380175
- FDA 510(k) database K141133
Across registries
- EUDAMED Basic UDI-DI 357302BUDI000299TZ registered 10 Sep 2026 Active
- FDA 510(k) K141133 decided 9 Jul 2015 Active
- FDA GUDID UDI-DI 03573026380175 listed 14 Sep 2016 Listed
Recalls
-
- Ongoing Z-0797-2023
- Ongoing Z-0864-2023
As the temperature and time out of range was exceeded, product performances cannot be guaranteed
-
- Ongoing Z-0427-2022
bioMerieux has been receiving an increasing number of complaints linked to a VIDAS substrate error. It prevents the test from being run, therefore leads to potential delayed results as the user must run another test.
-
- Terminated Z-0928-2020
Following Customers complaints, investigations have been initiated on potentially false results obtained on VIDAS 3 with an expired calibration. Indeed, the calibrations of assays were valid in the calibration menu whereas in fact the calibrations were expired and no alarm displayed to warn the users about the expiration date of the calibrations. Software computes results of analysis for assays with expired calibrations. The anomaly is due to an incorrect update of the calibration status by the software.
Timeline
- Cleared FDA 510(k) K141133
- Listed FDA GUDID 03573026380175
- Recall initiated FDA recalls Z-0928-2020
- Recall initiated FDA recalls Z-0427-2022
- Recall initiated FDA recalls Z-0797-2023
- Recall initiated FDA recalls Z-0864-2023
- Registered EUDAMED 357302BUDI000299TZ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Vidas® 3
- Generic name
- Fluorescent immunoassay analyser IVD, laboratory
- Model / reference
- 412590
- Primary DI / UDI-DI
- 03573026380175
- Basic UDI-DI
- 357302BUDI000299TZ
- 510(k) Number
- FDA product code
- JJE
- EMDN code
- W0201020101 AUTOMATED IMMUNOCHEMISTRY ANALYSERS - LOW ROUTINE (Throughput <= 100 test/h)
- GMDN term
- Fluorescent immunoassay analyser IVD, laboratory
- Device class
- Class A EUDAMEDClass I GUDID
- Regulation number
- 862.2160
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class A | Class I |
Similar devices in this category
Other devices filed under AUTOMATED IMMUNOCHEMISTRY ANALYSERS - LOW ROUTINE (Throughput <= 100 test/h).
- Bolt (CLIA) 00500-CL by Gold Standard Diagnostics, LLC
- ARCHITECT 1L86-01 01L8601 by Abbott Laboratories
- Specific Protein Analyzer PA54 by Genrui Biotech Inc.
- Triage 55071 by Quidel Cardiovascular Inc.
- Fluorescence Immunoassay Analyzer BKP1000 by BIOBASE POCT CO.,LTD
- Semi-auto Chemistry Analyzer 29-06-0002 by Shenzhen Zijian Biotechnology Co., Ltd
- VITROS 6801059 by Ortho-Clinical Diagnostics
- B·R·A·H·M·S KRYPTOR compact PLUS 106172 by B.R.A.H.M.S GmbH
- Chemiluminescence Analyzer Lumiray 680 by Rayto Life and Analytical Sciences Co., Ltd.
- Fully-auto Specific Protein Analyzer PA120 by Genrui Biotech Inc.