VIDCO NetViewer MDP2040-0100 is a centralized patient monitor (FDA Class II; FDA product code MSX, System,Network And Communication,Physiological Monitors) made by Vidco, Inc, listed in FDA GUDID since 22 Sep 2016 (UDI-DI 00863067000303), registry data as of 22 Oct 2026. One FDA recall is linked to it.

Listed FDA GUDID listing, no authorization on record

Valid until

Not applicable

Database listing, no authorization

FDA recalls

None ongoing

1 closed

Documents

None

No authorization documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00863067000303 UDI-DI Date22 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Remote Central Station
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Recalls

1 recall · FDA

    • Terminated Z-0582-2016 FDA Class II initiated 8 Nov 2015 catalog no. MDP2040-0100 listed

    Testing at customer site showed unit Remote Patient Monitoring System MDP2040-0100 in a continuous trap condition, not allowing system to reset and reboot. Two customers recently complained of the system freezing and it could only be restarted if the user re-applied power.

A catalog-number match means the recall lists this device's catalog or model number; the software version and lot are not checked.

Timeline

2 dated events

  1. Recall initiated FDA recalls Z-0582-2016
  2. Listed FDA GUDID 00863067000303

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Trade name
VIDCO NetViewer
Generic name
Centralized patient monitor
Model / reference
MDP2040-0100
Primary DI / UDI-DI
00863067000303
FDA product code
MSX
GMDN term
Centralized patient monitor
Device class
Class II
Regulation number
870.2300
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code MSX (System,Network And Communication,Physiological Monitors).

Other devices from Vidco, Inc

See all devices from Vidco, Inc →

Properties

  • Serial number
Other properties (14, all answered No)