ViewPoint 6 (5896732) is a medical image management system (EU MDR Class IIa; FDA Class II; FDA product code LLZ, System, image processing, radiological) made by GE Healthcare GmbH, registered in EUDAMED on 28 Jul 2022 (Basic UDI-DI 8406821BUG00018GX), cleared under FDA 510(k) K203677 on 15 Jan 2021 and listed in FDA GUDID since 15 Feb 2023 (UDI-DI 00195278517340), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K203677

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number00195278517340 UDI-DI Date15 Feb 2023ListedStatusListed GUDID: in commercial distribution
European UnionCE/MDR EUDAMED Number8406821BUG00018GX Basic UDI-DI 00195278517340UDI-DIDate28 Jul 2022RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK203677 Date15 Jan 2021DecidedStatusActive

Official records

From the FDA record

Device description
ViewPoint 6 v6.14
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00018GX registered 28 Jul 2022 Active
  • FDA 510(k) K203677 decided 15 Jan 2021 Active
  • FDA GUDID UDI-DI 00195278517340 listed 15 Feb 2023 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-3146-2024 FDA Class II initiated 8 Aug 2024

    The National Institute of Standards and Technology (NIST) has identified in the National Vulnerability Database (NVD) that NexGen Healthcare Mirth Connect, prior to version 4.4.1, has a potential vulnerability allowing the deserialization of untrusted data (CVE-2023-43208). Mirth products may have been installed and configured with your ViewPoint / ViewPoint 6 system by GE HealthCare. This vulnerability could allow a malicious actor to access the system and potentially manipulate patient data.

Timeline

4 dated events

  1. Cleared FDA 510(k) K203677
  2. Registered EUDAMED 8406821BUG00018GX
  3. Listed FDA GUDID 00195278517340
  4. Recall initiated FDA recalls Z-3146-2024

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
ViewPoint 6 EUDAMED
ViewPoint GUDID
Generic name
Medical image management system
Model / Ref / Catalog
ViewPoint 6 EUDAMED
5896732 EUDAMED
6. ver14 GUDID
H47591YA GUDID
Primary DI / UDI-DI
00195278517340
Basic UDI-DI
8406821BUG00018GX
Direct marketing DI
00195278517340
510(k) Number
FDA product code
LLZ
EMDN code
Z110603 Picture archiving and communication systems
GMDN term
Medical image management system
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.2050
Special device type
Software
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
ViewPoint 6
5896732
GUDID
6. ver14
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000005087

Similar devices in this category

Other devices filed under PICTURE ARCHIVING AND COMMUNICATION SYSTEMS.

Other devices from GE Healthcare GmbH

  • ViewPoint Ultra

    Class IIa
  • ViewPoint 6 Open recall

    Class IIa

Properties

  • Prescription use
  • Lot / batch number
Other properties (23, all answered No)