Skip to content

Viewpoint Ck System (Keratoplast Tip Component)

by Refractec, Inc.

PMA P010018

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

PMA P010018↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPPR Approved NumberP010018 Date11 Apr 2002ApprovedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Trade Name
Viewpoint(Tm) Ck System
Generic Name
Electrosurgical, radio frequency, refractive correction
PMA Number
FDA Product Code
MWD
Device Class
Class III
Advisory Committee
Ophthalmic
FDA Decision
APPR Approved

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Viewpoint CK System is an electrosurgical, radio frequency device designed for refractive correction. It is indicated for the temporary reduction of spherical hyperopia in patients aged 40 years or older who meet specific refractive criteria, including a cycloplegic spherical hyperopia range of 0.75 D to 3.25 D and minimal refractive astigmatism.

This system is manufactured by Refractec, Inc. and has received FDA PMA approval for its intended clinical use. The magnitude of refractive correction achieved with this treatment may diminish over time, with results varying among patients regarding the retention of the intended correction.

Other devices from Refractec, Inc.

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary function of the Viewpoint CK System?

    The Viewpoint CK System is an electrosurgical, radio frequency device used for the temporary reduction of spherical hyperopia in patients who meet specific refractive and age-related criteria.

  • Is the refractive correction provided by this system permanent?

    No, the magnitude of correction provided by the Viewpoint CK System diminishes over time, meaning the effect is considered temporary rather than permanent.

  • Who is a candidate for treatment with the Viewpoint CK System?

    Candidates must be 40 years of age or older with 0.75 D to 3.25 D of cycloplegic spherical hyperopia, less than or equal to 0.75 D of refractive astigmatism, and documented stability of refraction for the prior 12 months.