ViewSite Brain Access System
by Vycor Medical Inc. 19 variants
Ref TC060407
ViewSite Brain Access System (TC060407) is a neurosurgical retraction cannula (EU MDD Class III; FDA Class II; FDA product code GZT, Retractor, Self-Retaining, For Neurosurgery) made by Vycor Medical, Inc., registered in EUDAMED on 29 Feb 2024 (Basic UDI-DI B-00859261006012), cleared under FDA 510(k) K060973 on 26 Jul 2006 and listed in FDA GUDID since 21 Jun 2017 (UDI-DI 00859261006012), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00859261006012 00859261006012 | Date29 Feb 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00859261006012 | Date21 Jun 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK060973 | Date26 Jul 2006 | StatusActive |
Official records
- EUDAMED public site B-00859261006012
- AccessGUDID record 00859261006012
- FDA 510(k) database K060973
From the FDA record
- Device description
- THE VYCOR VIEWSITE BRAIN ACCESS SYSTEM (VBAS) is a family of retractor and brain access devices of varying shapes and sizes designed for providing diagnostic and surgical access to various portions of the brain and spine. It has been designed to serve as a self-retaining retractor system for brain tissue. It is comprised of an introducer and a working channel or port that are secured by a spring-loaded latch. Each device allows for the gentle retraction of tissue, visualization of the surgical site and for the smooth manipulation of introduced instruments. The range of device sizes (width and length) provides various working channel sizes.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00859261006012 registered 29 Feb 2024 Active
- FDA 510(k) K060973 decided 26 Jul 2006 Active
- FDA GUDID UDI-DI 00859261006012 listed 21 Jun 2017 Listed
Recalls
-
- Terminated Z-0673-2013
Vycor Medical recalled their VBAS (Vycor Viewsite Brain Access System) because an unidentified black fiber was found on the device.
Timeline
- Cleared FDA 510(k) K060973
- Recall initiated FDA recalls Z-0673-2013
- Listed FDA GUDID 00859261006012
- Registered EUDAMED B-00859261006012
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- ViewSite Brain Access System EUDAMEDVycor Viewsite Brain Access System GUDID
- Generic name
- Neurosurgical retraction cannula
- Model / reference
- TC060407
- Primary DI / UDI-DI
- 00859261006012
- Basic UDI-DI
- B-00859261006012
- 510(k) Number
- FDA product code
- GZT
- EMDN code
- K01020106 Minimally invasive surgery spreaders and retractors, single-use
- GMDN term
- Neurosurgical retraction cannula
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 882.4800
- System or procedure pack
- System which is a device in itself
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Sweden
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000007171
- Authorised representative
- MediMark Europe Sarl. FR-AR-000000182
Similar devices in this category
Other devices filed under MINIMALLY INVASIVE SURGERY SPREADERS AND RETRACTORS, SINGLE-USE.
- Livac Retractor System 56mm FG04178 by Livac Pty Ltd
- OCTOTM DSPC-001 by DalimsurgNET corporation
- Disposable Wound Retractors Silica gel by Changzhou Lookmed Medical Instrument Co., Ltd
- ENDOPATH DEXTRUS FLR01 by Ethicon Endo-Surgery, LLC
- Extra View OMS-XB1 by Covidien LP
- PDB OMS-PDB1000 by Covidien LP
- ACTIV O BV867SU by Aesculap AG
- T-Pea Lifter TPL5A180-B10 by PROTOMED SA
- Alexis Laparoscopic System C8501 by APPLIED MEDICAL RESOURCES CORP.
- COR-VALV 1011181 by Coroneo Inc