Identity
- Trade Name
- VISIONIX FDA UDI
- Generic Name
- Automated ophthalmic refractometer FDA UDI
- Device Name
- The VX130+ is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefractometer, keratometer, corneal topographer, tonometer, multi-slit pachymeter, tear-film analyzer , and retro illumination. The VX130+ is a multi-function diagnostic device combining wavefront aberometer, corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the central cornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil Image Image of the cornea relative to the iris Analysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT) Meibomian glands imaging Evaluation of tear meniscus height FDA UDI
- Model / Reference
- VX130+ FDA UDI
- Description
- The VX130+ is a multifunctional eye diagnostic device. There are several operation modes combined in a single platform: aberrometer, autorefractometer, keratometer, corneal topographer, tonometer, multi-slit pachymeter, tear-film analyzer , and retro illumination. The VX130+ is a multi-function diagnostic device combining wavefront aberometer, corneal topographer, retro-illuminator, tonometer and pachymeter, indicated for: Measuring the refraction of the eye giving both lower and higher order aberrations Measuring the shape of the cornea Retro-illumination imaging of the eye Measuring the intraocular pressure without contacting the eye for glaucoma evaluation Photographing the eye and taking images of the eye to evaluate the thickness of the central cornea. Full cornea thickness map Scheimpflug imaging Anterior chamber imaging Pupil Image Image of the cornea relative to the iris Analysis of the tear film and evaluation of tear film non-invasive tear break-up time (NITBUT) Meibomian glands imaging Evaluation of tear meniscus height FDA UDI
Identifiers
- Primary DI / UDI-DI
- 03664188000039 FDA UDI
- FDA Product Code
- HKX FDA UDIHKO FDA UDIMXK FDA UDI
- GMDN Term
- Automated ophthalmic refractometer FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 886.1930 FDA UDI886.1760 FDA UDI886.1850 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Automated ophthalmic refractometerOphthalmic tonometer, battery-operatedOptical pachymeter
Visionix by Luneau Technology Operations — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Optical pachymeter.
- VISIONIX — LUNEAU TECHNOLOGY OPERATIONS · Class II
- VISIONIX — LUNEAU TECHNOLOGY OPERATIONS · Class II
- VISIONIX — LUNEAU TECHNOLOGY OPERATIONS · Class II
- VISIONIX — LUNEAU TECHNOLOGY OPERATIONS · Class II
- VISIONIX — LUNEAU TECHNOLOGY OPERATIONS · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Luneau Technology Operations
Sources (1)
- FDA UDI ebcf8da6-c223-4c98-992a-1047b12299f5 33 fields · synced Jun 1, 2026