Skip to content

VistaPhone 8303-02

by VitalConnect, Inc.

VistaPhone 8303-02 is an electrocardiography telemetric monitoring system (FDA Class II; FDA product code DRG, Transmitters And Receivers, Physiological Signal, Radiofrequency) made by VitalConnect, Inc., cleared under FDA 510(k) K193343 on 20 Apr 2020 and listed in FDA GUDID since 15 Jan 2021 (UDI-DI 00850490007467), active as of 22 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K193343

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00850490007467 UDI-DI Date15 Jan 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK193343 Date20 Apr 2020DecidedStatusActive

Official records

From the FDA record

Device description
Vista Phone A21 relay device
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K193343 decided 20 Apr 2020 Active
  • FDA GUDID UDI-DI 00850490007467 listed 15 Jan 2021 Listed

Recalls

1 recall · FDA

    • Terminated Z-2537-2020 FDA Class II initiated 21 May 2020

    A healthcare provider (HCP) noticed a patient had a lowered historic SpO2 reading that the software should have triggered a notification to the care team, but no notification was found. A software defect was encountered causing the lack of notification. The defect could result in exposing a patient to potential hypoxia for a short window of time. The firm is correcting the software to bring the performance back into compliance with specifications.

Timeline

3 dated events

  1. Cleared FDA 510(k) K193343
  2. Recall initiated FDA recalls Z-2537-2020
  3. Listed FDA GUDID 00850490007467

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
VistaPhone
Generic name
Electrocardiography telemetric monitoring system
Model / Ref / Catalog
8303-02
Primary DI / UDI-DI
00850490007467
510(k) Number
FDA product code
DRG
GMDN term
Electrocardiography telemetric monitoring system
Device class
Class II
Regulation number
870.2910
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code DRG (Transmitters And Receivers, Physiological Signal, Radiofrequency).

Other devices from VitalConnect, Inc.

See all devices from VitalConnect, Inc. →

Properties

  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (12, all answered No)