by Biotex, Inc.

510(k) K053087

Visualase Cooled Laser Applicator System, Laser Diffusing Fiber, Cooling Catheter System is a medical device (FDA Class II; FDA product code GEX, Powered Laser Surgical Instrument) made by Biotex, Inc., cleared under FDA 510(k) K053087 on 1 Mar 2006, active as of 22 Oct 2026. 4 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

Recall on shared 510(k) K053087; other models may be affected

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK053087 Date1 Mar 2006ClearedStatusActive

Official records

From the FDA record

Received by the FDA
2 Nov 2005
FDA decision
1 Mar 2006 (Substantially Equivalent)
FDA review time
119 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K053087 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

5 recalls · 1 ongoing · FDA

    • Ongoing Z-0244-2023 FDA Class II initiated 14 Oct 2022 on shared 510(k) K053087

    Due to a defect in the outer pouch sterile seal

    • Terminated Z-2501-2018 FDA Class II initiated 23 Mar 2018

    Medtronic has become aware that certain lots of the VCLAS 3MM, 10MM, and 15MM laser diffusing fibers were not tested at intended laser power levels, due to an issue related to calibration of the test equipment, which can lead to the potential for low laser energy output from fiber or fiber burnout at lower wattage.

    • Terminated Z-0025-2018 FDA Class II initiated 27 Jul 2017

    The VCLAS 3mm, 10mm, and 15mm tip devices were not appropriately tested for saline leakage during the manufacturing process.

    • Terminated Z-2755-2017 FDA Class II initiated 7 Jun 2017

    Medtronic has become aware that the VCLAS 15MM TIP cap, also referred to as Tuohy Borst Adapter (TBA), may not be capable of creating a seal around the optical fiber to ensure adequate saline flow through the cooling system. When the TBA is unable to seal around the optical fiber, low retention force to the optical fiber may occur, causing saline to leak out of the TBA.

    • Terminated Z-1672-2016 FDA Class II initiated 9 May 2016

    Potential for the Visualase Cooled Laser Applicator System (VCLAS) catheters to melt during procedures.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K053087
  2. Recall initiated FDA recalls Z-1672-2016
  3. Recall initiated FDA recalls Z-2755-2017
  4. Recall initiated FDA recalls Z-0025-2018
  5. Recall initiated FDA recalls Z-2501-2018
  6. Recall initiated FDA recalls Z-0244-2023

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
GEX
Device class
Class II
Regulation
21 CFR Part 878.4810
Advisory committee
General, Plastic Surgery
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code GEX (Powered Laser Surgical Instrument).

Other devices from Biotex, Inc.

See all devices from Biotex, Inc. →