Vital Signs Monitor iM3s, iM3As, iM3Bs, iHM3s

by Edan Instruments, Inc.

510(k) K233038Ref iM3As, iM3Bs, ES3

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number69444138iM3SS2J Basic UDI-DI Date29 Jan 2026RegisteredStatusActive
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK233038 Date8 Mar 2024ClearedStatusActive
United StatesGUDID listing GUDID Number06944413813458 UDI-DI Date1 Feb 2021ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1144-2026 FDA Class II initiated 24 Oct 2025

    As a result of receiving an FDA It Has Come to Our Attention Letter (IHCTOA Letter) regarding potential cybersecurity issues with various of the firm device.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k) · GUDID

Full name
Vital Signs monitor, Model: iM3s, iM3As, iM3Bs, iHM3s
Trade Name
Vital Signs Monitor
Generic Name
General-purpose multi-parameter bedside monitor
Model / Reference
iM3Bs, iM3As, ES3
Primary DI / UDI-DI
06944413813458, 06944413813441, 06944413849174
Basic UDI-DI
69444138iM3SS2J, 69444138ES3STG
510(k) Number
FDA Product Code
MWI, DQA, FLL, DXN
EMDN Code
Z1203020202 Transportable/portable multi–parameter patient monitors
GMDN Term
General-purpose multi-parameter bedside monitor
Device Class
Class IIb EUDAMED
Class II 510(k)GUDID
Regulation
21 CFR Part 870.2300 510(k)GUDID
870.2700 GUDID
880.2910 GUDID
870.1130 GUDID
EU market of registration
Germany
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent
GUDID distribution status
In Commercial Distribution
MRI Safety
MR Unsafe

Truth per registry

3 sources · 1 field differs

FieldEUDAMED510(k)GUDID
Device ClassEUDAMED
Class IIb
510(k)
Class II
GUDID
Class II

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Vital Signs Monitor iM3s, iM3As, iM3Bs, and iHM3s is a patient monitoring device designed to continuously measure and display vital signs such as heart rate, blood pressure, oxygen saturation, and respiratory rate. These monitors are intended for use in clinical settings to provide real-time physiological data, supporting patient assessment and care.

The monitors are supplied as reusable medical devices and are intended for use in hospital environments, including intensive care units and general wards. They are regulated under FDA 510K and MDR authorisations, with the iM3 series and iHM3s models classified under product code MWI. Sterility and MRI safety specifications are not indicated in the provided data.

Other devices from Edan Instruments, Inc.

See all devices from Edan Instruments, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these monitors meant for single-use or can they be reused in a clinical setting?

    These monitors (iM3s, iM3As, iM3Bs, and iHM3s) are explicitly labeled as reusable medical devices, designed for repeated use in hospital environments like intensive care units and general wards. Since they are not described as single-use, they should be cleaned and maintained according to standard hospital protocols for reusable medical equipment.

  • What types of vital signs can the iM3s/iM3As/iM3Bs/iHM3s models measure, and how are they displayed?

    The device continuously measures and displays heart rate, blood pressure, oxygen saturation (SpO₂), and respiratory rate in real-time. These metrics are intended to support patient assessment and monitoring by providing immediate physiological data for clinical decision-making in settings like ICUs and wards.

  • What is the regulatory pathway for these monitors, and which advisory committee was involved?

    The monitors (iM3s, iM3As, iM3Bs, and iHM3s) follow the FDA 510(k) pathway and are also authorized under MDR (Medical Device Regulation). The Cardiovascular (CV) Advisory Committee reviewed the submission, and the device was determined to be substantially equivalent to a predicate under the Traditional 510(k) clearance type.

  • Are there different models, and if so, how do they differ in terms of intended use?

    Yes, the device family includes iM3s, iM3As, iM3Bs, and iHM3s, all classified under product code MWI (Monitoring, Vital Signs). While the exact functional differences between the models aren’t detailed here, they are all designed for continuous monitoring of vital signs in clinical settings, including intensive care and general wards. The variations may relate to features or configurations rather than core indications.

  • How should these monitors be stored, and are there any special considerations for their environment?

    The data does not specify storage conditions, but as reusable hospital-grade devices, they should be stored in a clean, dry environment away from direct sunlight or extreme temperatures. Since they are intended for intensive care and ward use, proper maintenance and calibration protocols should be followed to ensure accuracy and reliability in clinical settings.

Properties

  • Measuring Function
  • Prescription Use
  • Serial Number
  • Manufacturing Date

Other properties (20)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No