Vizadisc 107130
Ref 107130Model 08858251002257SR
Vizadisc 107130 is a device classified as Class IIa in the EU and Class II in the US made by MAKO Surgical Corp., registered in EUDAMED on 21 May 2026 (Basic UDI-DI 08858251002257SR), cleared under FDA 510(k) K141989 on 13 Nov 2014 (1 earlier submission) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 00848486002534), active as of 24 Oct 2026. 13 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08858251002257SR 00848486002534 | Date21 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00848486002534 | Date24 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK141989 | Date13 Nov 2014 | StatusActive |
Official records
- EUDAMED public site 08858251002257SR
- AccessGUDID record 00848486002534
- FDA 510(k) database K141989
- FDA 510(k) database K121064
Across registries
- EUDAMED Basic UDI-DI 08858251002257SR registered 21 May 2026 Active
- FDA 510(k) K141989 decided 13 Nov 2014 Active
- FDA GUDID UDI-DI 00848486002534 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-1735-2022
Certain units have the potential to exhibit infant failures whereby units either arrive non-functional, have the potential to become non-functional, or flash an error light while in use.
-
- Terminated Z-2745-2020
Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures.
-
- Terminated Z-2925-2018
Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera.
-
- Terminated Z-3131-2017
Software discrepancy of not showing all the EE constants, when the screen is filled.
-
- Terminated Z-1411-2017
Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides
-
- Terminated Z-1193-2017
Failure of the Offset Cup Reamer Handle not engaging its mating components.
-
- Terminated Z-1583-2016
Potential disassociation of the orientation pin.
-
- Terminated Z-1588-2016
Stryker Orthpaedics became aware that there is the potential for the 210540 MAKOplasty Hip Array Kit Laminate 150230 to list two part numbers for the RIO Base Array, which is item #5 on the product table.
-
- Terminated Z-0224-2016
The locking pin on the RIO Base Array is damaged during assembly onto the RIO Base Array Connector.
-
- Terminated Z-0829-2015
- Terminated Z-0830-2015
- Terminated Z-0828-2015
MAKO has identified the potential that the shell impactors may be damaged intraoperatively.
-
- Terminated Z-1508-2016
Revision of the field manual
Timeline
- Recall initiated FDA recalls Z-1588-2016
- Recall initiated FDA recalls Z-1583-2016
- Listed FDA GUDID 00848486002534
- Recall initiated FDA recalls Z-1193-2017
- Recall initiated FDA recalls Z-1411-2017
- Recall initiated FDA recalls Z-3131-2017
- Recall initiated FDA recalls Z-2925-2018
- Recall initiated FDA recalls Z-2745-2020
- Recall initiated FDA recalls Z-1735-2022
- Registered EUDAMED 08858251002257SR
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Mako EUDAMEDVizadisc GUDID
- Generic name
- Optical surgical tracking system spatial marker, single-use
- Device name
- TD-03 - MAKO - Class IIa - Tracker - Consumables - Metal and Plastic
- Model / Ref / Catalog
- 107130, 08858251002257SR
- Primary DI / UDI-DI
- 00848486002534
- Basic UDI-DI
- 08858251002257SR
- Direct marketing DI
- 00848486002534
- FDA product code
- OLO
- EMDN code
- Z12130485 Stereotactic orthopaedic surgery instruments - consumables
- GMDN term
- Optical surgical tracking system spatial marker, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 882.4560
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under STEREOTACTIC ORTHOPAEDIC SURGERY INSTRUMENTS - CONSUMABLES.
- 3D OFFSET IMAGING SET SPX1 A00038 by ECENTIAL ROBOTICS
- VELYS Baskets, Trays and Cases 4515-70-114 by DePuy Ireland UC
- Apollo Knee TKR.IN.1850 by CORIN LTD
- Navigation Set SPX1, Targeting Needle Bevel Tip – 11G, 125mm A00019 by ECENTIAL ROBOTICS
- NextAR Spine Platform 03.57.10.0001 by Medacta International SA
- VELYS 4515-70-005 by DePuy Ireland UC
- 8801085 NDI Sterile Passive Markers - 5 spheres in tray 1 tray per box OEM 509 by Northern Digital Inc
- 8801075 NDI Sterile Passive Markers - 5 spheres in tray 12 trays per box OEM 509 by Northern Digital Inc
- OMNIBotics RM-10000 by OMNIlife science, Inc.
- OMNIBotics RM-10003 by OMNIlife science, Inc.