# VNS Therapy®

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/vns-therapy-r-102>
- Manufacturer: [LivaNova USA, Inc.](https://devicerts.com/manufacturers/livanova-usa-inc) (United States)
- Device class: Active implantable (AIMDD) (EU AIMDD); Class III (US FDA)
- FDA product code: MUZ, LYJ
- EMDN: J020301 DRUG-RESISTANT EPILEPSY NON-SURGICAL THERAPY IMPLANTABLE NEUROSTIMULATORS
- EMDN: J020399 VAGAL IMPLANTABLE NEUROSTIMULATORS - OTHER
- GMDN: Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system (34210)

## Registrations and authorizations

- **EUDAMED** · CE/AIMDD · European Union · Basic UDI-DI B-05425025750016 · UDI-DI 05425025750016 · registered 2026-05-06 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 05425025750016 · listed 2014-09-17 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA PMA · United States · P970003 · decision 1997-07-16 · decision APPR · status: Active · from GUDID

## Recalls

- Z-1067-2025 · Class II · ongoing · initiated 2025-01-03: Their is a potential that implanted pulse generators may stop delivering therapy due to an internal component issue.
- Z-1068-2025 · Class II · ongoing · initiated 2025-01-03: Their is a potential that implanted pulse generators may stop delivering therapy due to an internal component issue.
- Z-1072-2025 · Class II · ongoing · initiated 2024-12-12: Vagus nerve stimulator generators may stop delivering stimulation due to an internal, mechanically activated component that may become stuck in a closed position, which may result in patients returning to baseline seizure frequency or depressive symptoms and in the longer term, patients may be required to undergo generator replacement surgery to replace their device.
- Z-0532-2022 · Class II · terminated · initiated 2021-12-02: A manufacturing issue may cause the silicone tubing wall thickness of vagus nerve stimulation leads to be less than the design specification. If the tubing becomes completely breached, the patient may experience discomfort or pain due to delivery of stimulation to an unintended location. If the inner lead conductor is exposed to body fluids the lead may break causing loss of therapy.
- Z-0462-2021 · Class II · terminated · initiated 2020-09-28: Due to an extra digit being inadvertently added to the serial number of a subset of implantable pulse generators, they become not compatible with therapy programmers with software version 11.0.4.
- Z-1563-2020 · Class II · ongoing · initiated 2020-02-04: False positive warning may occur after: 1) VNS Generator interrogated at 0mA normal output current, 2) Generator programmed to non-0mA output current, 3) In-session re-interrogation performed. Users instructed to lower output current and widen pulse width. Only system diagnostic testing evaluates output current. Users may conclude device malfunction, could lead to medical/surgical intervention.
- Z-0561-2020 · Class I · terminated · initiated 2019-08-22: Sentiva generators may reset and become disabled within 60 days of enabling. Physicians can re-enable but devices will continue to be susceptible to resets. If a device experiences this issue, this may lead to additional surgery (premature replacement of generator), or patients may return to baseline seizure frequency or depressive symptoms due to cessation of intended stimulation.
- Z-1118-2020 · Class II · terminated · initiated 2019-08-13: Firm identified a subset of its generators that were sterilized one additional sterilization cycle, which does not meet the firm's quality specifications.
- Z-0346-2020 · Class II · ongoing · initiated 2018-11-16: Lead impedance values reported by the affected VNS generator will be higher compared to those reported by previous models. This is due to a change in the timing of when affected VNS generator takes the lead impedance measurement during diagnostic testing. As a result, normal impedance ranges for the affected VNS generator have shifted relative to the existing thresholds of 600 - 5300 Ohms defined in labeling and as present in the programming software.
- Z-0663-2020 · Class II · ongoing · initiated 2018-11-16: This recall is being initiated due to reports that that the therapy programming tablet with software version 1.5 errantly performs a normal mode diagnostic test instead of the selected system diagnostic test on Model 102 and Model 102R devices, if the output current is greater than 0.5mA. This can result in false high impedance values during patient follow-up.
- Z-0868-2020 · Class II · terminated · initiated 2018-11-16: This recall is an expansion of Z-3019-2017 and Z-3020-2017, which was initiated to fix the devices premature battery depletion, caused by electrical leakage on the circuit board assemblies of the Models 105 and 106 generators. \*Note this recall occurred in November 2018.
- Z-0869-2020 · Class II · terminated · initiated 2018-11-16: This recall is an expansion of Z-3019-2017 and Z-3020-2017, which was initiated to fix the devices premature battery depletion, caused by electrical leakage on the circuit board assemblies of the Models 105 and 106 generators. \*Note this recall occurred in November 2018.
- Z-2572-2018 · Class II · terminated · initiated 2018-01-24: Unintended warning message displayed on generators programmed with a Model 3000 v.1.0.2.2 programmer.
- Z-0555-2018 · Class II · terminated · initiated 2017-12-02: Two Model 3000 Programmers were distributed in error by prior to FDA approval of version 1.0.2.2 software.
- Z-2255-2018 · Class II · terminated · initiated 2017-11-13: Certain Model 3000 programming events can result in miscalculation of parameters stored in the Models 103, 104, 105, and 106 generators. During these programming events, the miscalculations can lead to: " Delivery of more stimulation than intended, resulting in painful stimulation or other common side effects (Model 106 only); " No stimulation in the case of device disablement (Burst Watchdog Timeout), resulting in no therapy to the patient (Model 106 only); " Delivery of less stimulation than intended, resulting in therapeutic settings not being achieved within device specification (Models 103, 104, 105, or 106); and/or " Delays or absence of the 75% and 50% battery life indicators displayed by the programming software (Models 103, 104, 105, or 106).
- Z-0659-2016 · Class II · terminated · initiated 2015-12-18: Recall being initiated in response to three reports of "Burst Watchdog Timeout" events occurring with the Model 106 AspireSR Generator, resulting in a device reset condition where stimulation output is disabled.
- Z-0645-2016 · Class II · terminated · initiated 2015-11-18: Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat Detection' feature and exhibit the potential for decreased battery longevity.
- Z-0280-2016 · Class II · terminated · initiated 2015-10-07: Certain Model 106 Pulse Generators demonstrate delays in sensing during use of the 'Verify Heartbeat Detection' feature and exhibit potential for decreased battery longevity.
- Z-0858-2015 · Class II · terminated · initiated 2014-11-20: The recalled product was distributed with an incorrect serial number printed on the device's label.
- Z-0210-2012 ·  · terminated · initiated 2011-08-12: The devices are being recalled because the output current delivered to the vagus nerve is less than the design intent and there is a potential charge imbalance at the lead cathode and generator-can during stimulation.
- Z-0005-2012 ·  · terminated · initiated 2011-05-06: An investigation was initiated based on a report from the field in which an Intensive Follow-up Indicator (IFI) message was unexpectedly received by a medical professional when using Model 250 version 8.0 software to interrogate a patient's Model 103 Generator.
- Z-0006-2012 ·  · terminated · initiated 2011-05-06: An investigation was initiated based on a report from the field in which an Intensive Follow-up Indicator (IFI) message was unexpectedly received by a medical professional when using Model 250 version 8.0 software to interrogate a patient's Model 103 Generator.
- Z-1591-2010 ·  · terminated · initiated 2010-04-06: Battery life projection is inaccurate.
- Z-0994-2009 ·  · terminated · initiated 2008-02-07: Reset/disabling of the VNS Therapy Demipulse Generator and Demipulse Duo Generator due to magnet interference resulting in the loss of stimulation.
- Z-0995-2009 ·  · terminated · initiated 2008-02-07: Reset/disabling of the VNS Therapy Demipulse Generator and Demipulse Duo Generator due to magnet interference, resulting in the loss of stimulation.
- Z-0171-2008 ·  · terminated · initiated 2007-08-02: Dissolution/Fractures to the leads of the VNS Therapy System
- Z-0172-2008 ·  · terminated · initiated 2007-08-02: Dissolution/Fractures to the leads of the VNS Therapy System
- Z-0173-2008 ·  · terminated · initiated 2007-08-02: Dissolution/Fractures to the leads of the VNS Therapy System
- Z-0341-2007 ·  · terminated · initiated 2006-10-17: During programming, pulse generator may be inadvertently set to 8.0 mA output, regardless of the mA range selected by the clinician
- Z-0342-2007 ·  · terminated · initiated 2006-10-17: During programming, pulse generator may be inadvertently set to 8.0 mA output, regardless of the mA range selected by the clinician

## Identity

- Trade name: VNS Therapy® [EUDAMED]; VNS Therapy® Pulse Model 102 Generator [FDA GUDID (AccessGUDID)]
- Generic name: Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system [FDA GUDID (AccessGUDID)]
- Device name: VNS Therapy® Pulse™ Generator [EUDAMED]
- Model / reference: Model 102 [EUDAMED]; 102 [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 05425025750016 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: B-05425025750016 [EUDAMED]
- PMA number: P970003 [FDA GUDID (AccessGUDID)]
- FDA product code: MUZ [FDA GUDID (AccessGUDID)]; LYJ [FDA GUDID (AccessGUDID)]
- EMDN code: J020301 [EUDAMED]; J020399 [EUDAMED]
- GMDN term: Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system (34210) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class AIMDD [EUDAMED]; Class III [FDA GUDID (AccessGUDID)]
- EU registration type: Legacy device (under a directive) [EUDAMED]
- EU market of registration: Italy [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Conditional [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: VNS Therapy®, LivaNova USA, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/vns-therapy-r-102 (data as of 2026-11-24).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/vns-therapy-r-102.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/vns-therapy-r-102
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.