Skip to content

Siringa enterale 1 ml- NUTRISAFE2

by Pentaferte Italia SRL

Part of a family of 40 devices: see the family page

Ref 1015.014

Siringa enterale 1 ml- NUTRISAFE2 (1015.014) is an ENFit oral/enteral syringe (EU MDR Class I; FDA Class II; FDA product code KNT, Tubes, gastrointestinal (and accessories)) made by Pentaferte Italia SRL, registered in EUDAMED on 5 Jan 2026 (Basic UDI-DI 80152621044U), cleared under FDA 510(k) K060944 on 15 Sep 2006 and listed in FDA GUDID since 14 Mar 2024 (UDI-DI 08015262022242), active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K060944

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number80152621044U Basic UDI-DI 08015262022242UDI-DIDate5 Jan 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number08015262022242 UDI-DI Date14 Mar 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK060944 Date15 Sep 2006DecidedStatusActive

Official records

From the FDA record

Device description
1ML SYRINGE FOR SAFETY CONNECTION NUTRISAFE 2 VY-P
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 80152621044U registered 5 Jan 2026 Active
  • FDA 510(k) K060944 decided 15 Sep 2006 Active
  • FDA GUDID UDI-DI 08015262022242 listed 14 Mar 2024 Listed

Recalls

3 recalls · FDA

    • Terminated Z-0678-2018 FDA Class II initiated 24 Jul 2017 on shared 510(k) K060944

    Vygon is conducting a voluntary recall of the products and lots listed in this recall, being initiated because our Tyvek supplier has notified Vygon of issues with their product, specifically the Tyvek may not be coated completely causing gaps in the adhesive used to seal the product packaging. This potential lack of adhesive may affect the sterility of the product.

    • Terminated Z-1203-2010 FDA Unclassified (pre-2012) initiated 29 Jan 2010

    Mislabeled feeding syringes : 6 ml syringe mislabeled as 5 ml.

    • Terminated Z-1204-2010 FDA Unclassified (pre-2012) initiated 29 Jan 2010

    Mislabeled feeding syringes : 12 ml syringe mislabeled as 10 ml.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K060944
  2. Recall initiated FDA recalls Z-1203-2010
  3. Recall initiated FDA recalls Z-1204-2010
  4. Recall initiated FDA recalls Z-0678-2018
  5. Listed FDA GUDID 08015262022242
  6. Registered EUDAMED 80152621044U

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Siringa enterale 1 ml- NUTRISAFE2 EUDAMED
Vygon GUDID
Generic name
ENFit oral/enteral syringe, single-use
Device name
Siringhe E Accessori Enterali
Model / Ref / Catalog
1015.014
Primary DI / UDI-DI
08015262022242
Basic UDI-DI
80152621044U
510(k) Number
FDA product code
KNT
EMDN code
A020108 Enteral feeding syringes
GMDN term
ENFit oral/enteral syringe, single-use
Device class
Class I EUDAMED
Class II GUDID
Regulation number
876.5980
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 3 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II
Supplied sterileEUDAMED
Yes
GUDID
No
Sterilise before useEUDAMED
Yes
GUDID
No

Registry differences

EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:

  • Supplied sterile UDI-DI 08015262022242: EUDAMED states Yes, FDA GUDID states No.
  • Sterilise before use UDI-DI 08015262022242: EUDAMED states Yes, FDA GUDID states No.

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
IT-MF-000040982

Similar devices in this category

Other devices filed under ENTERAL FEEDING SYRINGES.

Other devices from Pentaferte Italia SRL

See all devices from Pentaferte Italia SRL →

Properties

  • Supplied sterile YesEUDAMEDNoGUDID
  • Sterilise before use YesEUDAMEDNoGUDID
  • Single use
  • Administering medicine
  • Measuring function
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)