Wiener Lab. Calibrator A Plus, Model 2X3 mL Cat. Nr. 1918006
510(k) K024305Ref 1918005
Active
Valid until
No expiry
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDD EUDAMED | NumberB-07798100043296 07798100043296 | Date9 Jun 2026 | StatusWithdrawn |
| United States | FDA 510(k)SESE 510(k) | NumberK024305 | Date18 Mar 2003 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- Calibrador A plus
- Model / Reference
- 1918005
- Primary DI / UDI-DI
- 07798100043296
- Basic UDI-DI
- B-07798100043296
- 510(k) Number
- FDA Product Code
- JIX
- EMDN Code
- W0101050301 Calibrators multicomponent (cc)
- Device Class
- Class IVD General EUDAMEDClass II 510(k)
- Regulation
- 21 CFR Part 862.1150
- Advisory Committee
- Clinical Chemistry
- FDA Decision
- SESE Substantially Equivalent
Truth per registry
| Field | EUDAMED | 510(k) |
|---|---|---|
| Device Class | Class IVD General | Class II |
Overview
AI-generated summary, 18 Sep 2026
The Wiener Lab. Calibrator A Plus is a multi-analyte mixture calibrator designed for use in clinical chemistry. It serves as a reference standard to ensure the accuracy and precision of laboratory assays, particularly for automated chemistry analyzers, by providing predefined concentrations of analytes for calibration purposes.
This device is supplied as a single-use liquid calibrator in a 2X3 mL volume and is intended for in vitro diagnostic use. Authorized under FDA 510(k) and IVDD regulations, it is classified as a Class II medical device. The calibrator requires proper storage as specified by the manufacturer and is not intended for reuse or reprocessing. No MRI safety information is provided, and its regulatory status is confirmed by the listed authorizations.
Other devices from Wiener Laboratories Saic
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Wiener Lab. Calibrator A Plus in a clinical chemistry lab?
The Wiener Lab. Calibrator A Plus is designed as a multi-analyte mixture calibrator to ensure the accuracy and precision of automated chemistry analyzers. It provides predefined concentrations of analytes, serving as a reference standard for calibration to maintain reliable assay performance in clinical chemistry testing.
How is the Wiener Lab. Calibrator A Plus supplied, and is it intended for single-use?
The calibrator is supplied as a single-use liquid in a 2×3 mL volume. It is explicitly intended for in vitro diagnostic use only and is not designed for reuse or reprocessing, as per manufacturer guidelines.
Does this calibrator require any special storage conditions, and can it be reused?
The device requires proper storage as specified by Wiener Laboratories, though exact conditions (e.g., temperature, light exposure) are not detailed in the provided data. Importantly, it is not intended for reuse or reprocessing—each unit is a single-use item.
What regulatory pathways does the Wiener Lab. Calibrator A Plus follow, and what class is it assigned?
The calibrator is authorized under FDA 510(k) and IVDD (In Vitro Diagnostic Directive) regulations. It is classified as a Class II medical device, with a decision of *Substantially Equivalent* (SESE) for its clinical chemistry applications.
Are there any safety considerations for this calibrator, such as MRI compatibility?
The provided data does not include any information regarding MRI safety for the Wiener Lab. Calibrator A Plus. Clinicians should assume it is not MRI-compatible unless explicitly stated otherwise by the manufacturer.
Properties
Other properties (5)
- Sterile: No
- Self Testing: No
- Near-Patient Testing: No
- Companion Diagnostics: No
- Surgical Instrument: No