Wiener Lab Got (Ast) UV Aa Liquida

by Wiener Laboratories Saic

510(k) K023551

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK023551 Date9 Dec 2002ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
CIT
Device Class
Class II
Regulation
21 CFR Part 862.1100
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Wiener Lab GOT (AST) UV AA Líquida is a quantitative in vitro diagnostic device classified under Nadh Oxidation/Nad Reduction and AST/SGOT assays. It measures glutamic oxaloacetic transaminase (GOT, AST) levels in liquid samples using ultraviolet absorbance (UV AA) technology, enabling precise biochemical analysis for clinical chemistry applications.

This device is supplied as a liquid reagent system for single-use in laboratory settings. It is intended for use with automated or semi-automated clinical chemistry analyzers and requires no additional sterilization beyond standard laboratory practices. The device has received FDA 510(k) clearance under the Traditional pathway, adhering to regulatory standards for Class II medical devices (regulation number: 862.1100). No MRI safety considerations or reusable components are specified.

Other devices from Wiener Laboratories Saic

See all devices from Wiener Laboratories Saic →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical chemistry applications does the Wiener Lab GOT (AST) UV AA Líquida support?

    The Wiener Lab GOT (AST) UV AA Líquida is a quantitative in vitro diagnostic device specifically designed for measuring glutamic oxaloacetic transaminase (GOT, AST) levels in liquid samples. It utilizes ultraviolet absorbance (UV AA) technology to enable precise biochemical analysis, making it suitable for clinical chemistry applications in laboratory settings. This allows clinicians to assess liver function and detect potential abnormalities in enzyme levels.

  • How is the Wiener Lab GOT (AST) UV AA Líquida supplied, and what are its usage requirements?

    This device is supplied as a liquid reagent system intended for single-use in laboratory environments. It is compatible with automated or semi-automated clinical chemistry analyzers. No additional sterilization beyond standard laboratory practices is required, as it is designed for one-time use in controlled settings. This ensures consistency and reduces the risk of contamination.

  • Is the Wiener Lab GOT (AST) UV AA Líquida reusable, and what are the regulatory considerations?

    The Wiener Lab GOT (AST) UV AA Líquida is explicitly designed for single-use only, meaning each vial or bottle is intended to be used once before disposal. Regulatory clearance for this device was granted under the FDA’s 510(k) Traditional pathway, confirming it meets Class II medical device standards (regulation number: 862.1100). This pathway ensures the device adheres to rigorous safety and performance requirements for in vitro diagnostics.

  • What types of analyzers can be used with the Wiener Lab GOT (AST) UV AA Líquida?

    The Wiener Lab GOT (AST) UV AA Líquida is engineered to function with automated or semi-automated clinical chemistry analyzers. These systems are commonly used in laboratories to process multiple samples efficiently while maintaining accuracy. The device’s compatibility with such analyzers ensures seamless integration into existing workflows for AST/GOT testing.

  • Are there any special storage requirements for the Wiener Lab GOT (AST) UV AA Líquida?

    While the provided data does not specify exact storage conditions, liquid reagent systems like the Wiener Lab GOT (AST) UV AA Líquida typically require storage in a cool, dry place, protected from direct light and extreme temperatures. Always refer to the manufacturer’s instructions or accompanying documentation for precise storage guidelines to maintain reagent integrity and ensure accurate test results.