Williams Cystoscopic Injection Needle

by Cook Incorporated

510(k) K171602Ref 090001-S10, 090001-S34, 090001-S26

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00827002152960 Basic UDI-DI Date26 May 2026RegisteredStatusActive
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Traditional NumberK171602 Date28 Jul 2017ClearedStatusActive
United StatesGUDID listing GUDID Number00827002152960 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-0163-2027 FDA Not yet classified initiated 16 Sep 2026

    The female Luer lock adapter component in the affected device lots may not have been correctly seated due to misalignment and inadequate torquing during manufacturing. Potential events that may occur as a result of this issue include increased procedural time and inadequate treatment.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k) · GUDID

Trade Name
Williams
Generic Name
General-purpose endoscopic needle, single-use
Model / Ref / Catalog
090001-S10, 090001-S34, 090001-S26, G15296, G16112, G16684
Primary DI / UDI-DI
00827002152960, 00827002161122, 00827002166844
Basic UDI-DI
B-00827002152960, B-00827002166844, B-00827002161122
510(k) Number
FDA Product Code
FBK
EMDN Code
A019099 Needles for other procedures - other
GMDN Term
General-purpose endoscopic needle, single-use
Device Class
Class IIa EUDAMED
Class II 510(k)GUDID
Regulation
21 CFR Part 876.1500
EU market of registration
Germany
Advisory Committee
Gastroenterology, Urology
FDA Decision
SESE Substantially Equivalent
GUDID distribution status
In Commercial Distribution

Truth per registry

3 sources · 2 fields differ

FieldEUDAMED510(k)GUDID
Model / ReferenceEUDAMED
090001-S10
090001-S34
090001-S26
510(k)
—
GUDID
G15296
G16112
G16684
Device ClassEUDAMED
Class IIa
510(k)
Class II
GUDID
Class II

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Williams Cystoscopic Injection Needle is an Endoscopic Injection Needle (per FDA nomenclature), designed for precise injection procedures within the urinary tract. It is intended for use in conjunction with cystoscopic systems to deliver substances such as sclerosing agents, gels, or other therapeutic solutions into bladder lesions, diverticula, or other targeted areas during urological interventions.

This device is supplied as a single-use, non-sterile instrument, intended for sterile preparation prior to use in clinical settings. It is classified as a Class II medical device under FDA regulations (876.1500) and has received FDA 510K clearance and MDD compliance. The needle is compatible with standard cystoscopes and must be handled according to aseptic techniques to ensure patient safety. No MRI safety information is specified.

Other devices from Cook Incorporated

See all devices from Cook Incorporated →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Williams Cystoscopic Injection Needle primarily used for in clinical practice?

    The Williams Cystoscopic Injection Needle is designed for precise injection procedures within the urinary tract, specifically to deliver therapeutic substances like sclerosing agents or gels. It is intended for use during cystoscopic interventions to target areas such as bladder lesions or diverticula, enabling controlled delivery of treatments directly to the affected site.

  • Is the Williams Cystoscopic Injection Needle sterile when received, and how should it be prepared for use?

    The Williams Cystoscopic Injection Needle is supplied as a non-sterile instrument and must be sterilized prior to clinical use. It is intended for sterile preparation in accordance with standard aseptic techniques to ensure patient safety before insertion into the urinary tract.

  • Can this needle be reused, or is it intended for single-use only?

    The Williams Cystoscopic Injection Needle is explicitly labeled as a single-use device. Reuse is not recommended or supported by the manufacturer, as it could compromise sterility and patient safety.

  • What cystoscopic systems is this needle compatible with, and are there any special handling requirements?

    The Williams Cystoscopic Injection Needle is designed to be compatible with standard cystoscopic systems. It must be handled using aseptic techniques to maintain sterility, as it is not pre-sterilized. Proper preparation and adherence to sterile procedures are critical before use.

  • What regulatory pathways has this device undergone, and how does it classify under medical device regulations?

    The Williams Cystoscopic Injection Needle has received FDA 510K clearance and complies with the MDD (Medical Device Directive). It is classified as a Class II medical device under FDA regulations (product code FBK, classification 876.1500), indicating it has undergone a traditional 510(k) review process for substantial equivalence.

Properties

  • Sterile
  • Single Use
  • Prescription Use
  • Lot / Batch Number
  • Expiration Date
  • Manufacturing Date

Other properties (16)

  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No