Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK182835 Date27 Mar 2019ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
QEW
Device Class
Class II
Regulation
21 CFR Part 870.5150
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Wolf Thrombectomy Device is a Peripheral Mechanical Thrombectomy With Aspiration system designed for the mechanical removal of emboli and thrombi from peripheral arterial blood vessels. It employs aspiration and mechanical fragmentation to clear occlusions in vascular pathways, facilitating restored blood flow without surgical intervention.

This device is supplied as a single-use, non-sterile system intended for use in clinical settings such as catheterization labs or interventional radiology. It is classified as a Class II medical device under FDA regulation 870.5150 and has received FDA 510(k) clearance (K182835) as substantially equivalent. Compatibility with MRI is not specified, and proper storage adheres to manufacturer guidelines for single-use devices.

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the Wolf Thrombectomy Device and how does it work?

    The Wolf Thrombectomy Device is designed for the mechanical removal of emboli and thrombi from peripheral arterial blood vessels. It combines aspiration and mechanical fragmentation to break down and clear blockages in vascular pathways, restoring blood flow without the need for surgical intervention. This approach helps maintain vascular integrity while addressing occlusions in catheterization labs or interventional radiology settings.

  • Is the Wolf Thrombectomy Device intended for single-use or reusable applications, and what does that mean for clinical settings?

    The Wolf Thrombectomy Device is supplied as a single-use system, meaning each device is intended for one procedure only. This design ensures patient safety by eliminating cross-contamination risks and simplifies clinical workflows, as no reprocessing or sterilization is required between uses. Clinicians must adhere to manufacturer guidelines for proper storage and handling to maintain its integrity.

  • How is the Wolf Thrombectomy Device packaged and stored, and does it require special handling?

    The device is supplied as a non-sterile system, intended for use in clinical settings like catheterization labs or interventional radiology. Since it is single-use, it must be stored according to the manufacturer’s guidelines to preserve its functionality. Proper storage ensures the device remains uncontaminated and ready for immediate use when needed, though clinicians should confirm specific storage conditions with 880 Medical, LLC.

  • What regulatory pathway was followed for the Wolf Thrombectomy Device, and what does that mean for its use in clinical practice?

    The Wolf Thrombectomy Device received FDA 510(k) clearance (K182835) under the Traditional pathway, demonstrating it is substantially equivalent to a legally marketed predicate device. This clearance confirms it meets FDA safety and effectiveness standards for Peripheral Mechanical Thrombectomy With Aspiration, allowing its use in clinical practice as described in the approved labeling. The device is classified as Class II under regulation 870.5150.

  • Are there different sizes or models of the Wolf Thrombectomy Device, and how might that affect its application?

    The device data includes multiple FEI numbers (e.g., 1000523114, 3002095335, etc.), which typically correspond to variations in catheter sizes, lengths, or other specifications. These differences allow clinicians to select the appropriate model based on the patient’s anatomy and the specific vascular occlusion being treated. For exact sizing details, refer to the manufacturer’s labeling or consult 880 Medical, LLC.