Skip to content

Xhibit Central

by Spacelabs Healthcare (Washington), Inc 9 variants

Xhibit Central (040-1040-03) is an electrocardiography monitoring system receiver (FDA Class II) made by Spacelabs Healthcare (Washington), Inc, cleared under FDA 510(k) K141156 on 9 Sep 2014 and listed in FDA GUDID since 6 Jan 2017 (UDI-DI 10841522120244), active as of 23 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

510(k) K141156

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10841522120244 UDI-DI Date6 Jan 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK141156 Date9 Sep 2014DecidedStatusActive

Official records

From the FDA record

Device description
KIT,DUAL ANT,ACT,W/OPS, 614,W/2AMP
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K141156 decided 9 Sep 2014 Active
  • FDA GUDID UDI-DI 10841522120244 listed 6 Jan 2017 Listed

Recalls

6 recalls · 3 ongoing · FDA

    • Ongoing Z-0809-2025 FDA Class II initiated 25 Nov 2024

    Telemetry receiver systems may experience a Windows proxy Issue causing the system to shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occurred during this period, staff may not detect until the system restarts; necessary clinical intervention could be delayed.

    • Ongoing Z-0810-2025 FDA Class II initiated 25 Nov 2024

    Telemetry receivers with affected software versions may experience unsolicited system shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occurred during this period, staff may not detect until the system restarts and necessary clinical intervention could be delayed.

    • Ongoing Z-1513-2022 FDA Class II initiated 31 May 2022

    Software related alarm escalation defect occurs after approximately 25 days of continuous use. Technical alarm escalation for the following alarms, signal loss, all leads off, low battery, SpO2 sensor off, and signal interference, does not occur in the telemetry receiver as specified. Caregiver may not respond to the initial technical alarm and may not be aware of the continuing technical failure.

    • Terminated Z-0532-2018 FDA Class II initiated 17 Jan 2018

    Spacelabs has received multiple complaints reporting telemetry beds dropping off the Spacelabs Central Station resulting in a loss of monitoring.

    • Terminated Z-2886-2016 FDA Class II initiated 25 Aug 2016

    The firm received multiple reports of Xhibit Telemetry System going offline or locking up. In addition, short-duration asystole alarms may not display an audio and visual alarm as reported from a single Canadian hospital.

    • Terminated Z-1502-2016 FDA Class II initiated 28 Mar 2016

    Reports of an abnormally high frequency of squelch events on Xhibit Telemetry Receivers (XTR), which is indicative of the loss of the telemetry data signal. In some cases, the Xhibit Central Monitor was also reported to display an Xhibit Offline error message for all patients being monitored.

Timeline

8 dated events

  1. Cleared FDA 510(k) K141156
  2. Recall initiated FDA recalls Z-1502-2016
  3. Recall initiated FDA recalls Z-2886-2016
  4. Listed FDA GUDID 10841522120244
  5. Recall initiated FDA recalls Z-0532-2018
  6. Recall initiated FDA recalls Z-1513-2022
  7. Recall initiated FDA recalls Z-0809-2025
  8. Recall initiated FDA recalls Z-0810-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Xhibit
Generic name
Electrocardiography monitoring system receiver
Model / Ref / Catalog
Xhibit Central, 040-1040-03
Primary DI / UDI-DI
10841522120244
510(k) Number
FDA product code
MSX, MHX, MLD, DSI
GMDN term
Electrocardiography monitoring system receiver
Device class
Class II
Regulation number
870.2300, 870.1025
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code MSX (SYSTEM,NETWORK AND COMMUNICATION,PHYSIOLOGICAL MONITORS).

Other devices from Spacelabs Healthcare (Washington), Inc

See all devices from Spacelabs Healthcare (Washington), Inc →

Properties

  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)