Zenition 50

by Philips Medical Systems Nederland B.V.

510(k) K183101

Active European Union and United States

CE MDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Abbreviated NumberK183101 Date31 Dec 2018ClearedStatusActive
European UnionCE/MDR EUDAMED Number— Date—StatusActive

Recalls

6 recalls · 5 ongoing · FDA

    • Ongoing Z-0241-2026 FDA Class II initiated 29 Sep 2025

    Over time some systems may experience loss of imaging functionality and/or poor image quality due to potential corrosion of the Image Intensifier Television (IITV) control board.

    • Ongoing Z-1580-2025 FDA Class II initiated 25 Feb 2025

    A wireless foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation.

    • Ongoing Z-0352-2025 FDA Class II initiated 7 Oct 2024

    Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure.

    • Ongoing Z-0226-2024 FDA Class II initiated 4 Oct 2023

    Philips has become aware of an issue with the Philips Integris-Allura, Allura Xper and Azurion systems that have been delivered to Puerto Rico without a warning label and the Source-to-Skin Distance Spacer (Tube-spacer) is missing.

    • Ongoing Z-0647-2022 FDA Class II initiated 2 Dec 2021

    Firm discovered that the wireless foot switch can suddenly stop responding due to a firmware issue. If the wireless foot switch fails, there could be a delay or interruption of procedure if the hand switch is not used or if the wired foot switch is not connected to the system.

    • Terminated Z-1932-2020 FDA Class II initiated 10 Apr 2020

    When strain relief is lost at the stand side of the Stand MVS Trolley Cable, over time one or more electrical contacts could break due to pulling, twisting, or dropping of the connector. If this happens, live parts may be exposed (230 V) and/or the video signal can be lost.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

510(k) Number
FDA Product Code
OWB
Device Class
Class II
Regulation
21 CFR Part 892.1650
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Zenition 50 is an Interventional Fluoroscopic X-Ray System, designed for real-time imaging during surgical and interventional procedures. It employs a mobile C-arm configuration with an integrated image intensifier to provide high-quality fluoroscopic views, enabling precise guidance for procedures such as orthopedics, cardiology, and vascular interventions.

This system is intended for use in clinical settings where portability and flexibility are required, such as operating rooms, catheterization labs, and interventional radiology suites. Supplied as a reusable medical device, it adheres to FDA 510(k) clearance and MDR regulatory standards. The Zenition 50 operates within Class II risk classification and includes multiple FEI numbers and registration numbers for compliance tracking. Storage and handling follow standard protocols for fluoroscopic equipment, with no indication of single-use or MRI compatibility.

Other devices from Philips Medical Systems Nederland B.V.

See all devices from Philips Medical Systems Nederland B.V. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of procedures is the Zenition 50 designed to support with its real-time imaging capabilities?

    The Zenition 50 is specifically designed for real-time imaging during surgical and interventional procedures in fields like orthopedics, cardiology, and vascular interventions. Its mobile C-arm configuration with an integrated image intensifier provides high-quality fluoroscopic views, making it ideal for guiding precise interventions in settings such as operating rooms, catheterization labs, and interventional radiology suites.

  • Is the Zenition 50 a single-use or reusable device, and what does this mean for maintenance and costs?

    The Zenition 50 is a reusable medical device, meaning it is intended for repeated use after proper cleaning, disinfection, and maintenance. This design reduces per-procedure costs but requires adherence to manufacturer guidelines for reprocessing to ensure safety, sterility, and performance consistency over multiple uses.

  • How is the Zenition 50 regulated, and what does this imply for its use in clinical settings?

    The Zenition 50 is authorized under both FDA 510(k) clearance and the EU’s Medical Device Regulation (MDR), classifying it as a Class II device. This regulatory pathway ensures it meets stringent safety and performance standards for interventional fluoroscopic systems, allowing its use in clinical settings where portability and flexibility are critical, such as ORs and catheterization labs.

  • What storage and handling requirements should be followed for the Zenition 50 to maintain its functionality?

    While specific storage details aren’t provided, as a reusable fluoroscopic system, the Zenition 50 should be stored in a clean, dry environment protected from physical damage, extreme temperatures, and electromagnetic interference. Manufacturer guidelines likely include regular maintenance checks and calibration to ensure optimal imaging quality and safety during use.

  • Does the Zenition 50 come with multiple configurations or models, and how might this affect procedure planning?

    The Zenition 50 is described as a single interventional fluoroscopic system with a mobile C-arm design, but it includes multiple FEI (Facility Equipment Identifier) and registration numbers, suggesting compliance tracking across various institutional setups. While no specific models are mentioned, its adaptability for orthopedics, cardiology, and vascular procedures implies versatility in procedure planning, though exact configurations would depend on institutional customization or accessories.