Zenition 70

by Philips Medical Systems Nederland B.V.

Ref 718133Model Zenition 70

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED Number0884838BM350SQ Basic UDI-DI 00884838091528UDI-DIDate19 Jun 2023RegisteredStatusActive
European UnionCE/MDR EUDAMED Number0884838BM350SQ Basic UDI-DI 00884838091528UDI-DIDate19 Jun 2023RegisteredStatusActive
United StatesFDA 510(k) 510(k) NumberK212813 Date1 Oct 2021IssuedStatusActive
United StatesGUDID listing GUDID Number00884838091528 UDI-DI Date4 Apr 2019ListedStatusListed GUDID: in commercial distribution

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

6 recalls · 5 ongoing · FDA

    • Ongoing Z-1581-2025 FDA Class II initiated 25 Feb 2025

    A wireless foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation.

    • Ongoing Z-0353-2025 FDA Class II initiated 7 Oct 2024

    Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure.

    • Ongoing Z-0226-2024 FDA Class II initiated 4 Oct 2023

    Philips has become aware of an issue with the Philips Integris-Allura, Allura Xper and Azurion systems that have been delivered to Puerto Rico without a warning label and the Source-to-Skin Distance Spacer (Tube-spacer) is missing.

    • Ongoing Z-1583-2025 FDA Class II initiated 20 Jul 2023

    Philips has become aware of the potential for unintended radiation exposure with Zenition 70 systems with Vascular Extension option and a Wireless Foot Switch.

    • Ongoing Z-0648-2022 FDA Class II initiated 2 Dec 2021

    Firm discovered that the wireless foot switch can suddenly stop responding due to a firmware issue. If the wireless foot switch fails, there could be a delay or interruption of procedure if the hand switch is not used or if the wired foot switch is not connected to the system.

    • Terminated Z-1933-2020 FDA Class II initiated 10 Apr 2020

    When strain relief is lost at the stand side of the Stand MVS Trolley Cable, over time one or more electrical contacts could break due to pulling, twisting, or dropping of the connector. If this happens, live parts may be exposed (230 V) and/or the video signal can be lost.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD, CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k) · GUDID

Trade Name
Zenition 70 EUDAMED
Zenition GUDID
Generic Name
Mobile general-purpose fluoroscopic x-ray system, digital
Model / Ref / Catalog
Zenition 70, 718133
Primary DI / UDI-DI
00884838091528
Basic UDI-DI
0884838BM350SQ, B-00884838091528
FDA Product Code
OXO, JAA, OWB
EMDN Code
Z11039017 Mobile radioscopic units
GMDN Term
Mobile general-purpose fluoroscopic x-ray system, digital
Device Class
Class IIb EUDAMED
Class II GUDID
Regulation Number
892.1650
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device ClassEUDAMED
Class IIb
GUDID
Class II

Manufacturer details

EUDAMED SRN
NL-MF-000001489

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Zenition 70 is a mobile C-arm imaging system with a flat detector, designed for radiographic procedures. It falls under the nomenclature code Z11039017 and is classified as a Class IIb radiology device, enabling high-resolution X-ray imaging for intraoperative and procedural guidance in various clinical settings.

This device is non-sterile, non-reusable, and intended for single-use applications. It incorporates flat detectors (FD12 or FD15) and is regulated under FDA 510(k) clearance (K212813) and the Medical Device Directive (MDD) with subsequent compliance under the Medical Device Regulation (MDR). The Zenition 70 is supplied as an active medical device with a unique device identifier (UDI) for traceability, ensuring compliance with regulatory standards.

Other devices from Philips Medical Systems Nederland B.V.

See all devices from Philips Medical Systems Nederland B.V. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of clinical procedures is the Zenition 70 designed to support with its imaging capabilities?

    The Zenition 70 is a mobile C-arm imaging system with a flat detector, specifically designed for radiographic procedures to provide high-resolution X-ray imaging. It is intended for intraoperative and procedural guidance across various clinical settings, such as orthopedics, trauma, or interventional radiology, where real-time imaging is critical for precision and safety.

  • Is the Zenition 70 system reusable, and if not, what does this mean for its maintenance and cost?

    The Zenition 70 is explicitly designed for single-use only, meaning it is not intended to be reprocessed or reused after a single procedure. This eliminates the need for sterilization or maintenance between uses, simplifying workflows and reducing the risk of cross-contamination. However, buyers should account for the higher per-procedure cost compared to reusable systems, as each use requires a new unit.

  • What flat detector options are available for the Zenition 70, and how might they affect imaging performance?

    The Zenition 70 system incorporates two flat detector models: FD12 and FD15. These detectors are likely optimized for different imaging requirements, such as field of view or resolution. While the exact specifications (e.g., size, resolution) aren’t detailed here, the choice between them would depend on clinical needs—such as the need for broader coverage (e.g., FD15) or higher detail (e.g., FD12). Consulting Philips’ technical documentation would clarify performance differences.

  • How is the Zenition 70 regulated, and what does this mean for healthcare providers in terms of compliance?

    The Zenition 70 is regulated under FDA 510(k) clearance (K212813) and complies with the Medical Device Directive (MDD) and Medical Device Regulation (MDR) in Europe. This means it has undergone regulatory review for safety and performance, ensuring it meets standards for high-resolution radiographic imaging. Providers must ensure proper handling, storage, and disposal in accordance with local regulations, as it is non-sterile and single-use.

  • What storage requirements should be considered for the Zenition 70 to maintain its functionality and compliance?

    Since the Zenition 70 is non-sterile and single-use, it does not require sterile storage conditions. However, it should be stored in a clean, dry environment protected from physical damage, extreme temperatures, or moisture to preserve its integrity. The system’s UDI (0884838BM350SQ) enables traceability, so storage areas should allow for easy identification and inventory management. Always follow Philips’ guidelines for unpacking and setup to ensure optimal performance.

Properties

  • Measuring Function
  • Prescription Use
  • Serial Number

Other properties (21)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No
  • Manufacturing Date: No