Skip to content

Zyno A2-80071-PF

by Zyno Medical LLC.

Zyno A2-80071-PF is an electric infusion pump administration set (FDA Class II; FDA product code FPA, Set, Administration, Intravascular) made by Zyno Medical LLC., cleared under FDA 510(k) K132841 on 23 Jan 2014 and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 10814371020102), active as of 23 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

6 closed

Documents

510(k) K132841

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10814371020102 UDI-DI Date23 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK132841 Date23 Jan 2014DecidedStatusActive

Official records

From the FDA record

Device description
A2 Administration Primary Set: 105" 1 NF Y-Site Above Pump, In-line 0.22 Filter, Back Check-Valve. A2 Primary Administration Sets are single-use IV administration sets for use with Z-800 Zyno Medical Infusion pump. All A2 Primary sets fluid paths are sterile, non-Pyrogenic, are not made with natural rubber latex, and are not made with DEHP.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K132841 decided 23 Jan 2014 Active
  • FDA GUDID UDI-DI 10814371020102 listed 23 Sep 2016 Listed

Recalls

6 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2058-2019 FDA Class II initiated 29 May 2019
    • Terminated Z-2059-2019 FDA Class II initiated 29 May 2019

    Administration sets assembled with inverted pinch clamp cause the fluid from the distal end of the administration set to be pumped to the proximal end of the tubing when secondary set is used with the primary set. Thus, instead of delivering fluid to the patient, blood may be drawn from the patient if there is space in the drug container to hold extra volume of fluid, under the condition that the reversed pinch clamp is not identified

  • 4 recalls, same reason

    • Terminated Z-2893-2016 FDA Class II initiated 29 Jul 2016
    • Terminated Z-2894-2016 FDA Class II initiated 29 Jul 2016
    • Terminated Z-2895-2016 FDA Class II initiated 29 Jul 2016
    • Terminated Z-2896-2016 FDA Class II initiated 29 Jul 2016

    Administration Set potential filter leaking

Timeline

8 dated events

  1. Cleared FDA 510(k) K132841
  2. Recall initiated FDA recalls Z-2893-2016
  3. Recall initiated FDA recalls Z-2894-2016
  4. Recall initiated FDA recalls Z-2895-2016
  5. Recall initiated FDA recalls Z-2896-2016
  6. Listed FDA GUDID 10814371020102
  7. Recall initiated FDA recalls Z-2058-2019
  8. Recall initiated FDA recalls Z-2059-2019

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Zyno
Generic name
Electric infusion pump administration set, single-use
Model / Ref / Catalog
A2-80071-PF
Primary DI / UDI-DI
10814371020102
510(k) Number
FDA product code
FPA
GMDN term
Electric infusion pump administration set, single-use
Device class
Class II
Regulation number
880.5440
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Electric infusion pump administration set, single-use.

Other devices from Zyno Medical LLC.

  • Zyno B2-70071-P

    Class II
  • Zyno B2-70070

    Class II
  • Z-800 Open recall

    Class II
  • Zyno BX-70072

    Class II

See all devices from Zyno Medical LLC. →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)