# Accuray Incorporated

> Medical device manufacturer record on deviCERTS, compiled from public registries. Accuray Incorporated is a medical device manufacturer based in the United States, with 85 devices listed in FDA GUDID, FDA 510(k) and EUDAMED (FDA Class II; EU Class IIb and I) and 28 FDA recalls as of 28 Nov 2026.

- Canonical page: <https://devicerts.com/manufacturers/accuray-incorporated>
- Country: United States (from SRN)
- EUDAMED actor status: active
- Role: Manufacturer
- Registrations: EUDAMED, FDA
- EUDAMED SRN: US-MF-000010238
- FDA FEI: 3003873069
- DUNS: 080044624

## Figures

- Devices: 85
- FDA recalls (matched to the firm by name): 28, 2 ongoing

## Registry facts

*Every device of the manufacturer. A device listed in two registries counts in both.*

- Registries: FDA GUDID 65, FDA 510(k) 21, EUDAMED 4
- Device classes: FDA Class II 81, EU Class IIb 3, EU Class I 1
- EMDN [Z11 Bioimaging and radiotherapy instruments](https://devicerts.com/categories/emdn/Z11): 4 devices

## Sites and related companies

- Authorised representative: [Emergo Europe B.V.](https://devicerts.com/representatives/emergo-europe-bv-nl-ar-000000116) (Netherlands)

## Devices

The first 50 of 85, in the order of the canonical page, which lists them all.

- [Adapt LTE Powered by Cenos](https://devicerts.com/devices/adapt-lte-powered-by-cenos-1097715-000) · ref 1097715-000 · Class I · EUDAMED, GUDID · status: Active
- [TomoTherapy Treatment Delivery System with iDMS 1068286](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-ce445055) · Class II · GUDID · status: Active
- [CyberKnife VSI® System 033000-000](https://devicerts.com/devices/cyberknife-vsi-r-system-98ba4d9e) · Class II · GUDID · status: Listed
- [Accuray Precision® Treatment Planning System 1055096](https://devicerts.com/devices/accuray-precision-r-treatment-planning-system-017d910e) · Class II · GUDID · status: Listed
- [CyberKnife® M6™ Systems 053101-M-000](https://devicerts.com/devices/cyberknife-r-m6-systems-de6976d1) · Class II · GUDID · status: Active
- [TomoTherapy Treatment System (Tomo HD™) H-0000-0003](https://devicerts.com/devices/tomotherapy-treatment-system-tomo-hd-3bc00011) · Class II · GUDID · status: Active
- [Accuray Precision Treatment Planning System 1070891](https://devicerts.com/devices/accuray-precision-treatment-planning-system-df195cad) · Class II · GUDID · status: Active
- [Radixact®, Treatment Delivery Console 1055487](https://devicerts.com/devices/radixact-r-treatment-delivery-console-5926edd9) · Class II · GUDID · status: Listed
- [iDMS™ Data Management System 1062409](https://devicerts.com/devices/idms-data-management-system-5ae6dff0) · Class II · GUDID · status: Active
- [TomoTherapy Treatment Delivery System with iDMS 1068283](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-20bd3c16) · Class II · GUDID · status: Active
- [TomoTherapy Treatment Delivery System with iDMS 1068286](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-7ffec45f) · Class II · GUDID · status: Active
- [1062424](https://devicerts.com/devices/na-65ae9102) · Class II · GUDID · status: Active
- [Accuray Precision® Treatment Planning System 1061799](https://devicerts.com/devices/accuray-precision-r-treatment-planning-system-3965e2a9) · Class II · GUDID · status: Active
- [Accuray Precision® Treatment Planning System 1064270](https://devicerts.com/devices/accuray-precision-r-treatment-planning-system-6dc016b0) · Class II · GUDID · status: Active
- [CyberKnife® M6™ Systems 053401-M-000](https://devicerts.com/devices/cyberknife-r-m6-systems-61c8cec5) · Class II · GUDID · status: Active
- [Accuray Precision® Treatment Planning System 1059811](https://devicerts.com/devices/accuray-precision-r-treatment-planning-system-7e3647a8) · Class II · GUDID · status: Active
- [TomoHDA® Treatment Delivery System 1018286-000](https://devicerts.com/devices/tomohda-r-treatment-delivery-system-19938b2d) · Class II · GUDID · status: Active
- [CyberKnife® VSI™ Robotic Radiosurgery System 033000-000](https://devicerts.com/devices/cyberknife-r-vsi-robotic-radiosurgery-system-b4c1da48) · Class II · GUDID · status: Listed
- [CyberKnife® VSI™ System 032500-M-000](https://devicerts.com/devices/cyberknife-r-vsi-system-05555eed) · Class II · GUDID · status: Active
- [Radixact®, Treatment Delivery Console (TDC) 1056593](https://devicerts.com/devices/radixact-r-treatment-delivery-console-tdc-a522c453) · Class II · GUDID · status: Listed
- [TomoTherapy Treatment Delivery System with iDMS 1068283](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-ae7422a3) · Class II · GUDID · status: Active
- [Delivery Analysis TM 1057375](https://devicerts.com/devices/delivery-analysis-tm-5e9e85d6) · Class II · GUDID · status: Active
- [Delivery Analysis TM 1052591](https://devicerts.com/devices/delivery-analysis-tm-d2d44886) · Class II · GUDID · status: Active
- [Delivery Analysis 1062213](https://devicerts.com/devices/delivery-analysis-5fa6bfa4) · Class II · GUDID · status: Active
- [Radixact™ Treatment Delivery System 1060253](https://devicerts.com/devices/radixact-treatment-delivery-system-666960df) · Class II · GUDID · status: Active
- [CyberKnife® Treatment Delivery System 0660000](https://devicerts.com/devices/cyberknife-r-treatment-delivery-system-6a88f65b) · Class II · GUDID · status: Active · open recall
- [TomoH® Treatment Delivery System 1018284-000](https://devicerts.com/devices/tomoh-r-treatment-delivery-system-eb8f8fa5) · Class II · GUDID · status: Active
- [CyberKnife® M6™ Systems 053201-M-000](https://devicerts.com/devices/cyberknife-r-m6-systems-220ef5a4) · Class II · GUDID · status: Listed
- [Radixact Treatment Delivery System 1080200](https://devicerts.com/devices/radixact-treatment-delivery-system-b5c4e894) · Class II · GUDID · status: Active
- [CyberKnife® Treatment Delivery System 1061945](https://devicerts.com/devices/cyberknife-r-treatment-delivery-system-2f8498ee) · Class II · GUDID · status: Active · open recall
- [iDMS Data Management System 1061513](https://devicerts.com/devices/idms-data-management-system-774520b9) · Class II · GUDID · status: Active
- [CyberKnife® M6™ Systems 1047641-000](https://devicerts.com/devices/cyberknife-r-m6-systems-862df35a) · Class II · GUDID · status: Listed
- [TomoTherapy Treatment Delivery System with iDMS 1068284](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-0cb4b8fc) · Class II · GUDID · status: Active
- [Delivery Analysis 1064315](https://devicerts.com/devices/delivery-analysis-c8ecd0f0) · Class II · GUDID · status: Active
- [reNEW™ Certified Pre-Owned System H-0000-0003](https://devicerts.com/devices/renew-certified-pre-owned-system-e3b4a2a6) · Class II · GUDID · status: Active
- [Radixact®, Treatment Delivery Console (TDC) 1057727](https://devicerts.com/devices/radixact-r-treatment-delivery-console-tdc-8594c072) · Class II · GUDID · status: Active
- [Onrad Treatment System 1049211](https://devicerts.com/devices/onrad-treatment-system-c8249a23) · Class II · GUDID · status: Active
- [reNEW™ Certified Pre-Owned System H-0000-0003](https://devicerts.com/devices/renew-certified-pre-owned-system-ebd0267b) · Class II · GUDID · status: Active
- [CyberKnife® M6™ Systems 053201-M-000](https://devicerts.com/devices/cyberknife-r-m6-systems-60d446f7) · Class II · GUDID · status: Active
- [TomoHDA® Treatment Delivery System 1018286-000](https://devicerts.com/devices/tomohda-r-treatment-delivery-system-5af6ee70) · Class II · GUDID · status: Listed
- [TomoHD® Treatment Delivery System 1018283-000](https://devicerts.com/devices/tomohd-r-treatment-delivery-system-f42dee69) · Class II · GUDID · status: Listed
- [CyberKnife® M6™ Systems 053301-M-000](https://devicerts.com/devices/cyberknife-r-m6-systems-6a4ec467) · Class II · GUDID · status: Active
- [Accuray Precision Treatment Planning System 1063143](https://devicerts.com/devices/accuray-precision-treatment-planning-system-1be0faee) · Class II · GUDID · status: Active
- [TomoTherapy Treatment Delivery System with iDMS 1068284](https://devicerts.com/devices/tomotherapy-treatment-delivery-system-with-idms-035adbe9) · Class II · GUDID · status: Active
- [iDMS Data Management System 1061514](https://devicerts.com/devices/idms-data-management-system-38ee4274) · Class II · GUDID · status: Active
- [Accuray Precision® Treatment Planning System 1050242](https://devicerts.com/devices/accuray-precision-r-treatment-planning-system-7c7e2f0d) · Class II · GUDID · status: Listed
- [Radixact®, Treatment Delivery Console (TDC) 1050241](https://devicerts.com/devices/radixact-r-treatment-delivery-console-tdc-e9163d0a) · Class II · GUDID · status: Listed
- [TomoHD® Treatment Delivery System 1018283-000](https://devicerts.com/devices/tomohd-r-treatment-delivery-system-9254e45e) · Class II · GUDID · status: Active
- [1060464](https://devicerts.com/devices/na-b0346a79) · Class II · GUDID · status: Active
- [CyberKnife® Treatment Delivery System 1055810](https://devicerts.com/devices/cyberknife-r-treatment-delivery-system-a1eace86) · Class II · GUDID · status: Active · open recall

## FDA recalls (matched by name, newest first)

- Z-2640-2026 · Class II · Ongoing · initiated 2026-06-16 · product code IYE: In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collimator may release and fall from the housing.
- Z-2644-2026 · Class II · Ongoing · initiated 2026-06-16 · product code IYE: In certain cases, a collimator may not fully dock, which triggers a system interlock and prevents motion from the operator console. If personnel then enter the treatment room and initiate motion using the in-room control pendant, the collimator may release and fall from the housing.
- Z-1023-2025 · Class II · Completed · initiated 2024-12-23 · product code IYE: Snap rings may become partially or completed detached from the shafts within the internal mechanism. Uncontrolled rotation may occur on the left and right roll axes when the rings are removed or damaged.
- Z-2489-2023 · Class II · Completed · initiated 2023-08-03 · product code IYE: It is possible the upper roller bracket in the Radixact System gantry enclosure may not provide enough clearance for service personnel to use a jib crane for moving components while servicing the system, resulting in possible injury to the service personnel.
- Z-1272-2021 · Class II · Terminated · initiated 2021-02-26 · product code IYE: The set screws that connect the Standard Treatment Couch linkage arm to the roll motor can loosen over time allowing the couch to roll.
- Z-0784-2021 · Class II · Terminated · initiated 2020-12-10 · product code IYE: "MLC tickle error" may result in the delivered dose to effectively rotate from the planned dose.
- Z-0785-2021 · Class II · Terminated · initiated 2020-12-10 · product code IYE: "MLC tickle error" may result in the delivered dose to effectively rotate from the planned dose.
- Z-0408-2019 · Class II · Terminated · initiated 2018-09-26 · product code IYE: A robotics supplier notified Accuray of two manufacturing variations in the fastening of the in-line wrist and the casting of the wrist for the robot. The variation may result in premature failure of the component.
- Z-3211-2018 · Class II · Terminated · initiated 2018-08-31 · product code IYE: the Ball Cube II phantom calibration film was not manufactured within necessary dimensions and may introduce up to 0.5 mm of positional inaccuracy to the CyberKnife System
- Z-1696-2019 · Class II · Terminated · initiated 2018-04-10 · product code IYE: There is an unintended drop of a secondary collimator housing that can occur during housing Xchange(TM) workflows. Specifically, during an automated housing Xchange, an interlock may interrupt this operation causing the collimator housing to partially attach.
- Z-1697-2019 · Class II · Terminated · initiated 2018-04-10 · product code IYE: There is an unintended drop of a secondary collimator housing that can occur during housing Xchange(TM) workflows. Specifically, during an automated housing Xchange, an interlock may interrupt this operation causing the collimator housing to partially attach.
- Z-0286-2018 · Class II · Terminated · initiated 2017-11-17 · product code IYE: Uncontrolled couch Z-axis movement (descent)
- Z-0287-2018 · Class II · Terminated · initiated 2017-11-17 · product code IYE: Uncontrolled couch Z-axis movement (descent)
- Z-0288-2018 · Class II · Terminated · initiated 2017-11-17 · product code IYE: Uncontrolled couch Z-axis movement (descent)
- Z-0289-2018 · Class II · Terminated · initiated 2017-11-17 · product code IYE: Uncontrolled couch Z-axis movement (descent)
- Z-0865-2017 · Class II · Terminated · initiated 2016-12-06 · product code IYE: Accuray has become aware of a potential safety issue involving the possibility of electric shock during maintenance activities from the lon Pump HV Power Supply at the back of the modulator cabinet. This issue is limited to certain G3, G4, and VSI models of the CyberKnife Robotic Radiosurgery System.
- Z-0734-2017 · Class II · Terminated · initiated 2016-11-22 · product code IYE: Accuray has become aware of a potential safety issue involving unexpected treatment robot motion when removing an accessory. This issue is limited to certain CyberKnife Systems with software version 1 0.6.
- Z-0771-2016 · Class II · Terminated · initiated 2016-01-22 · product code IYE: The gun box mounting bracket may fail to support the weight of the gun box when in vertical (inverted) position. If this failure occurs the gun box may become loose and could come into contact with a patient.
- Z-0218-2015 · Class II · Terminated · initiated 2014-10-31 · product code IYE: Software upgrade to correct potential safety issue related to CyberKnife System that occurs when upgrading the Treatment Delivery Software for the first generation Iris Variable Aperture Collimator.
- Z-0828-2014 · Class II · Terminated · initiated 2014-01-13 · product code IYE: Potential Safety issue with Synchrony Boom Arm Mounting Assembly - one complaint of mounting assembly detaching.
- Z-1155-2013 · Class II · Terminated · initiated 2013-03-27 · product code JAI: A5 gearboxes responsible for pitch (head up and head down) and roll (patient left and right) motions of the RoboCouch manipulator may be defective.
- Z-1126-2013 · Class II · Terminated · initiated 2013-03-19 · product code IYE: A defect on the master-side connector block of the pneumatic tool changer could introduce a tilt in the collimator housings, resulting in a potential shift to the central axis of the radiation beam. The issue could pose significant clinical impact to plans created using the smallest collimators.
- Z-1098-2012 · Not yet classified · Terminated · initiated 2012-01-16 · product code IYE: An anomaly was discovered during internal regression testing, where the dose information is displayed incorrectly during treatment planning during a specific workflow using the optional 4D Ray Tracing dose calculation algorithm. As a result, it is possible that the dose calculation will display a lower dose than the intended dose prescribed for treatment delivery.
- Z-0382-2012 · Unclassified (pre-2012) · Terminated · initiated 2011-11-07 · product code IYE: User Facility reported an anomaly where inhale and exhale CT pairs used for treatment planning did not represent the same magnitude of respiration that was displayed during treatment delivery.
- Z-0035-2012 · Unclassified (pre-2012) · Terminated · initiated 2011-09-12 · product code IYE: A report and investigation determined that the set screws, which were part of the retrofit of a previous recall were incorrectly engaged which allowed rotation and subsequent descent of the assembly.

## Source and citation

- Cite as: Accuray Incorporated. deviCERTS medical device catalogue. https://devicerts.com/manufacturers/accuray-incorporated (data as of 2026-11-28).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID](https://accessgudid.nlm.nih.gov/), [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA registration and listing](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfrl/rl.cfm), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- EUDAMED record synced: 2026-11-07
- FDA recall data as of: 2026-11-01
- Data as of: 2026-11-28
- JSON: <https://devicerts.com/manufacturers/accuray-incorporated.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/manufacturers/accuray-incorporated
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.