  "format": "devicerts.manufacturer.v1",
  "cite_as": "Balt USA LLC. deviCERTS medical device catalogue. https://devicerts.com/manufacturers/balt-usa-llc (data as of 2026-11-29).",
  "source": {
    "canonical_url": "https://devicerts.com/manufacturers/balt-usa-llc",
    "json_url": "https://devicerts.com/manufacturers/balt-usa-llc.json",
    "markdown_url": "https://devicerts.com/manufacturers/balt-usa-llc.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      },
      {
        "registry": "FDA GUDID",
        "url": "https://accessgudid.nlm.nih.gov/"
      },
      {
        "registry": "FDA 510(k)",
        "url": "https://open.fda.gov/apis/device/510k/"
      },
      {
        "registry": "FDA PMA",
        "url": "https://open.fda.gov/apis/device/pma/"
      },
      {
        "registry": "FDA recalls",
        "url": "https://open.fda.gov/apis/device/recall/"
      }
    ],
    "eudamed_record_synced": "2026-11-07",
    "fda_recalls_as_of": "2026-11-01",
    "registry_facts_computed": "2026-11-29",
    "status_as_of": "2026-11-29",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/manufacturers/balt-usa-llc",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "manufacturer": {
    "name": "Balt USA LLC",
    "url": "https://devicerts.com/manufacturers/balt-usa-llc",
    "registered_as": null,
    "abbreviated_name": null,
    "also_registered_as": [],
    "country": "United States",
    "country_basis": "from SRN",
    "eudamed_status": {
      "status": "active",
      "since_year": null
    },
    "verified": false,
    "roles": [
      "Manufacturer"
    ],
    "registrations": [
      "EUDAMED"
    ],
    "identifiers": [
      {
        "label": "EUDAMED SRN",
        "value": "US-MF-000008651"
      },
      {
        "label": "DUNS",
        "value": "945543689"
      }
    ],
    "summary": "Balt USA LLC is a medical device manufacturer based in the United States, with 1,031 devices listed in 4 registries (FDA Class II and III; EU Class III and IIa) and 8 FDA recalls as of 29 Nov 2026.",
    "noindex": false
  },
  "counts": {
    "devices": 1031,
    "devices_note": null,
    "certificates": 0,
    "fda_recalls_matched_by_name": 8,
    "fda_recalls_ongoing": 8,
    "fda_recalls_ongoing_recent": 8,
    "fda_recalls_ongoing_before": null,
    "fda_establishments": 0,
    "sites": 0
  },
  "registry_facts": {
    "covers": "Every device of the manufacturer. A device listed in two registries counts in both.",
    "registries": [
      {
        "registry": "FDA GUDID",
        "devices": 1010
      },
      {
        "registry": "EUDAMED",
        "devices": 556
      },
      {
        "registry": "FDA 510(k)",
        "devices": 19
      },
      {
        "registry": "FDA PMA",
        "devices": 1
      }
    ],
    "device_classes": [
      {
        "class": "FDA Class II",
        "devices": 1015
      },
      {
        "class": "FDA Class III",
        "devices": 13
      },
      {
        "class": "EU Class III",
        "devices": 2
      },
      {
        "class": "EU Class IIa",
        "devices": 1
      }
    ],
    "top_emdn_categories": [
      {
        "code": "Z12",
        "name": "Instruments for functional explorations and therapeutic interventions",
        "url": "https://devicerts.com/categories/emdn/Z12",
        "devices": 3
      }
    ]
  },
  "related": {
    "site_of": null,
    "part_of": null,
    "sites": [],
    "authorised_representatives": [
      {
        "name": "Emergo Europe B.V.",
        "url": "https://devicerts.com/representatives/emergo-europe-bv-nl-ar-000000116",
        "country": "Netherlands"
      }
    ]
  },
  "devices": {
    "shown": 50,
    "total": 1031,
    "all_devices_url": "https://devicerts.com/manufacturers/balt-usa-llc",
    "items": [
      {
        "name": "Neurovascular embolization device",
        "url": "https://devicerts.com/devices/neurovascular-embolization-device-opti0611cst10",
        "model_reference": "OPTI0611CST10",
        "device_class": "Class III",
        "registries": [
          "EUDAMED"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Neurovascular embolization device",
        "url": "https://devicerts.com/devices/neurovascular-embolization-device-opti1447com18",
        "model_reference": "OPTI1447COM18",
        "device_class": "Class III",
        "registries": [
          "EUDAMED"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Next Generation 088 Catheter NG088110",
        "url": "https://devicerts.com/devices/next-generation-088-catheter-ng088110-4918cbd9",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Next Generation 088 Catheter NG088115",
        "url": "https://devicerts.com/devices/next-generation-088-catheter-ng088115-710c92a2",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID12KIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid12kit-424f9d63",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Prestige Coil System PRESPACK30",
        "url": "https://devicerts.com/devices/prestige-coil-system-prespack30-ce676a1d",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Prestige Coil System PRESPACK65",
        "url": "https://devicerts.com/devices/prestige-coil-system-prespack65-e13abdfb",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Prestige Coil System PRESPACK55",
        "url": "https://devicerts.com/devices/prestige-coil-system-prespack55-9493d69a",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Prestige Coil System PRESPACK55",
        "url": "https://devicerts.com/devices/prestige-coil-system-prespack55-90f45726",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Carrier XL Delivery Catheter CR8088162",
        "url": "https://devicerts.com/devices/carrier-xl-delivery-catheter-cr8088162-02e17492",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Carrier XL Delivery Catheter CR8088142",
        "url": "https://devicerts.com/devices/carrier-xl-delivery-catheter-cr8088142-1fcd4063",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID12LDKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid12ldkit-8357466b",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID18KIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid18kit-85d7833c",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID18LDKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid18ldkit-5863c1a2",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID34LDKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid34ldkit-9885a3d2",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID123MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid123mlkit-c3036783",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID34KIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid34kit-47b900e5",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID12LD3MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid12ld3mlkit-0e1edf6b",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID183MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid183mlkit-ed2aed9d",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID18LD3MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid18ld3mlkit-8ce4ffe1",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID343MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid343mlkit-818f72a8",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "SQUID Liquid Embolic Agent SQUID34LD3MLKIT",
        "url": "https://devicerts.com/devices/squid-liquid-embolic-agent-squid34ld3mlkit-d00b68fc",
        "model_reference": null,
        "device_class": "Class III",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Carrier XL Delivery Catheter CR8088152",
        "url": "https://devicerts.com/devices/carrier-xl-delivery-catheter-cr8088152-b429a541",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Listed",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX1014",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax1014-6d958366",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX0512",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax0512-a9c5d871",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX1012",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax1012-da014d17",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX1512",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax1512-9cbad7bf",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX2012",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax2012-9f846b20",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX0514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax0514-ca6e71db",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX1514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax1514-e78020fa",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX3014",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax3014-9d357b7e",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX4514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax4514-07812d27",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX6514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax6514-39a41467",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX3014",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax3014-eeb451eb",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX4514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax4514-be51ffaa",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIPAX6514",
        "url": "https://devicerts.com/devices/optima-coil-system-optipax6514-997089b8",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL0512",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill0512-2098d3d2",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL1012",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill1012-75f2d752",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL1512",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill1512-c0a061c8",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL2012",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill2012-3a46a3f3",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL0514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill0514-a49b9740",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL1014",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill1014-ba8fa6b4",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL1514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill1514-e34d8e3d",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL3014",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill3014-71c4ae62",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL4514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill4514-ef793333",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL6514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill6514-90d2e2e4",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL3014",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill3014-e10206b8",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL4514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill4514-a3d41fc3",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Optima Coil System OPTIFILL6514",
        "url": "https://devicerts.com/devices/optima-coil-system-optifill6514-8746b363",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      },
      {
        "name": "Volare Microcatheter VLRE26F150",
        "url": "https://devicerts.com/devices/volare-microcatheter-vlre26f150-23e96141",
        "model_reference": null,
        "device_class": "Class II",
        "registries": [
          "GUDID"
        ],
        "status": "Active",
        "decision_date": null,
        "open_recall": false
      }
    ]
  },
  "certificates": [],
  "recalls": [
    {
      "number": "Z-0188-2026",
      "classification": "Class I",
      "status": "Ongoing",
      "initiated": "2025-09-25",
      "product_code": "DQY",
      "reason": "Due to an identified manufacturing defect involving coating material lifting within the catheter's distal inner diameter/lumen."
    },
    {
      "number": "Z-1988-2025",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2025-05-08",
      "product_code": "HCG",
      "reason": "Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification."
    },
    {
      "number": "Z-1989-2025",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2025-05-08",
      "product_code": "KRD",
      "reason": "Due to radiopaque (RO) marker was not visible during angiography and it was determined that the RO marker was not manufactured to specification."
    },
    {
      "number": "Z-1041-2024",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2024-01-03",
      "product_code": "HCG",
      "reason": "Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher. Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli."
    },
    {
      "number": "Z-1042-2024",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2024-01-03",
      "product_code": "KRD",
      "reason": "Discoloration was identified along the delivery pusher which was attributed to corrosion of the hypotube. The material which caused the corrosion was identified as remnants of solder flux residue remaining on the hypotube component of the delivery pusher.  Due to the location of the delivery pusher within the delivery system, it is possible for the discoloration to mechanically break off from the delivery pusher, leaving the potential for the material to flow through the delivery system (i.e. microcatheter), and into the patient vasculature causing foreign emboli."
    },
    {
      "number": "Z-0103-2023",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2022-09-07",
      "product_code": "HCG",
      "reason": "Product pouch label does not match up with carton label"
    },
    {
      "number": "Z-1680-2022",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2022-07-26",
      "product_code": "HCG",
      "reason": "Products were released to customers prior to the approval and release of a test report authorizing the use of an existing material from an alternate supplier."
    },
    {
      "number": "Z-0660-2022",
      "classification": "Class II",
      "status": "Ongoing",
      "initiated": "2022-01-04",
      "product_code": "HCG",
      "reason": "Due to Label/Pouch mix-up.  Pouches incorrectly labeled. Incorrect shelf carton label or pouch label due to inadequate manufacturing line clearance. As a result of this labeling mix-up, there is the possibility of inadvertently selecting the incorrect coil size for the procedure potentially causing some harms like vessel damage, an inability to treat with said device and potential rupture of the aneurysm."
    }
  ]
}