Page 1 of 16| Device | Model / Reference | Registries | Class | Status |
|---|---|---|---|---|
| Clearlink | 2N8371 | FDA UDI | Class II | Active |
| Fluid Systems Accessories | 2N3364 | FDA UDI | Class II | Active |
| Exactamix | H938741 | FDA UDI | Class II | Active |
| Exactamix | H938742 | FDA UDI | Class II | Active |
| Coseal Spray Set | 1514243 | FDA UDI | Class III | Active |
| Novum IQ | 40800BAXUSRF | FDA UDI | Class II | Active |
| Clearlink/Duo-Vent | 2R8420 | FDA UDI | Class II | Active |
| Preveleak Surgical Sealant | ADS201808 | FDA UDI | Class III | Active |
| Novum IQ | 40700BAXUSD | FDA UDI | Class II | Active |
| Clearlink/Buretrol | 2R8864 | FDA UDI | Class II | Active |
| Fluid Systems Accessories | 2N3368 | FDA UDI | Class II | Active |
| Exactamed | H93874205 | FDA UDI | Class I | Active |
| Duo - Duo-Vent | 2R8404 | FDA UDI | Class II | Active |
| Exactamed | H9387100 | FDA UDI | Class I | Active |
| Extension Set | 2N3359 | FDA UDI | Class II | Active |
| Repeater | H93811 | FDA UDI | Class II | Active |
| Extension Set | 2N3363 | FDA UDI | Class II | Active |
| Supor | H93824648 | FDA UDI | Class II | Unknown |
| Novum IQ | 40800BAXUS | FDA UDI | Class II | Active |
| Exactamix | H938743 | FDA UDI | Class II | Active |
| Exactamix | H9382400-M | FDA UDI | Class II | Active |
| Extension Set | 2N3360 | FDA UDI | Class II | Active |
| Exactamix | EXACTA-LCR | FDA UDI | Class II | Active |
| Exactamix | EXACTA12-DYR | FDA UDI | Class II | Active |
| Extension Set | 2N3356 | FDA UDI | Class II | Active |
| Novum IQ | 40800BAXUSL | FDA UDI | Class II | Active |
| Seprafilm | 508602 | FDA UDI | Class III | Active |
| Floseal Hemostatic Matrix | 1503350 | FDA UDI | Class III | Active |
| Tisseel/Artiss Spray Set | 1504265 | FDA UDI | Class II | Active |
| Dose Iq Safety Software | DOSEIQW0001 | FDA UDI | Class II | Active |
| Exactamix | EXACTA24-DY | FDA UDI | Class II | Active |
| Abacus | 83003392 | FDA UDI | Class II | Active |
| TipStop | 114555 | FDA UDI | Class I | Unknown |
| Clearlink/Duo-Vent | 2C7462 | FDA UDI | Class II | Active |
| Tisseel/Artiss Spray Set | 1504272 | FDA UDI | Class II | Unknown |
| Exactamix | EXM24DYR | FDA UDI | Class II | Active |
| Floseal | 1505291 | FDA UDI | Class III | Active |
| Interlink | 2C6401 | FDA UDI | Class II | Active |
| Exactamed | H9387501 | FDA UDI | Class I | Active |
| Repeater | H938099ER | FDA UDI | Class II | Active |
| PerClot | PCET038 | FDA UDI | Class III | Active |
| Homechoice Claria | 5C6M40 | FDA UDI | Class II | Active |
| Clearlink/Continu-Flo/Duo-Vent | 2R8538 | FDA UDI | Class II | Active |
| Exactamed | H93847 | FDA UDI | Class II | Active |
| Exactamed | H9387101 | FDA UDI | Class I | Active |
| Clearlink/Continu-Flo | ALT2403 | FDA UDI | Class II | Active |
| Minicap With Povidone-Iodine Solution | 5C4466P | FDA UDI | Class II | Active |
| Revaclear | Revaclear 500 | FDA UDI | Class II | Active |
| Minicap Extended Life Pd Trns | 5C4482A | FDA UDI | Class II | Active |
| Clearlink/Continu-Flo | ALT2402 | FDA UDI | Class II | Active |
Related Companies
Authorised Representatives
No authorised representatives on record.
Importers
Not available yet.
Notified Bodies
Not available yet.
Authorities
Not available yet.
FDA Recalls (100)
Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.
| Date | Recall No. | Class | Status | Reason |
|---|---|---|---|---|
| Apr 22, 2026 | Z-2262-2026 | — | open, classified | Affected lots may contain incorrect 0.8-micron filters. Use of a 0.8-micron filter in place of the validated 3-micron filter may lead to reduced flow efficiency, incomplete or slower transfers of ingredients, or system alarms. This issue may lead to clinical effects such as electrolyte imbalance, metabolic instability, delayed recovery, etc. |
| Feb 18, 2026 | Z-1637-2026 | — | open, classified | Urgent Medical Device Correction for the Volara system single-patient use circuit due to the potential that patients or caregivers may be unaware of a possible decrease in oxygen levels (oxygen desaturation), or potential lung tissue injury from overexpansion (barotrauma) when the Volara device is used in the home care environment. This correction is providing the home caregiver specific instructions for use. |
| Feb 18, 2026 | Z-1573-2026 | — | open, classified | Display screen may unintentionally flicker due to a software issue. Exposure to flickering lights may induce photosensitive seizure activity in susceptible individuals. |
| Jan 13, 2026 | Z-1368-2026 | — | open, classified | Pumps were released without full testing being performed, including occlusion alarm testing. |
| Nov 28, 2025 | Z-1121-2026 | — | open, classified | Certain pumps have potentially been released from service with defective grease applied to the cam and motor gears. Due to its low viscosity, the defective grease may lead to the device having insufficient lubrication on the cam, which could lead to premature wear of the mechanism assembly, resulting in over-infusion or a free-flow situation. |
| Oct 28, 2025 | Z-0847-2026 | — | open, classified | Replacement bladder kit for the Welch Allyn two-piece reusable blood pressure cuff may contain a Large Adult size bladder rather than a Thigh size bladder in the replacement kits. |
| Sep 17, 2025 | Z-0233-2026 | — | open, classified | Affected oral/axillary probes were inadvertently programmed with the rectal probe configuration. Affected probes will potentially display a lower temperature than the true value, which may lead to a delay in managing fever-related symptoms or infection. |
| Aug 29, 2025 | Z-0194-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0196-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0198-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0191-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0199-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0200-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0189-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0192-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0193-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0204-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0202-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0203-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0201-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0197-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0195-2026 | — | open, classified | IV sets may leak. |
| Aug 29, 2025 | Z-0190-2026 | — | open, classified | IV sets may leak. |
| Aug 8, 2025 | Z-2594-2025 | — | open, classified | Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for one lot of Continu-Flo solution sets listed below due to customer reports of tubing separation. |
| Aug 4, 2025 | Z-2334-2025 | — | open, classified | Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only). |
| Aug 4, 2025 | Z-2333-2025 | — | open, classified | Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only). |
| Aug 4, 2025 | Z-2332-2025 | — | open, classified | Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction for the Novum IQ Large Volume Pump (LVP) and Novum IQ Syringe Pump (SP) due to software anomalies that may result in a blank Run screen (LVP and SP) and/or false motor movement system error (SP only). |
| Jul 14, 2025 | Z-2415-2025 | — | open, classified | Baxter has identified that certain pumps have potentially been released with the grease applied to the cam and motor gears that will break down quickly. The breakdown of the grease will lead to the device having insufficient or ineffective grease applied to the cam, which could lead to premature wear of the mechanism assembly, resulting in excessive therapy. |
| Jul 14, 2025 | Z-2173-2025 | — | open, classified | Baxter is issuing an Urgent Medical Device Correction for the Novum IQ large volume pump (LVP) due to the potential for underinfusion when transitioning from a flow rate to a higher flow rate that is more than double. (e.g., rate change or bolus). The level of underinfusion is variable based on the current infusion rate, the duration the pump has been running at this flow rate, and the magnitude of the rate change. The longer the duration the pump has been running at the current infusion rate and the larger the magnitude of the rate change, the larger the underinfusion that would be experienced. Additionally, Baxter has identified an increase in customer reports of over and underinfusion potentially due to set misloading. Failure to properly load the tubing into the pump channel may result in the pump infusing at a rate higher or lower than programmed. Consistent with the instructions for use, customers should ensure that: 1) The door is fully open before loading the set. 2) The tubing is taut and loaded without slack in the pumping channel. |
| Jun 20, 2025 | Z-2095-2025 | — | open, classified | Certain Spectrum infusion pumps may have an incorrect version of software. |
| Jun 20, 2025 | Z-2096-2025 | — | open, classified | Certain Spectrum infusion pumps may have an incorrect version of software. |
| May 30, 2025 | Z-2032-2025 | — | open, classified | The Q-link 13 could allow for an improper attachment (false latching) of the Quick-Release Hook used on Sling Bars and other accessories. This could result in a critical injury from a patient fall as the false latched component may initially bear weight but can loosen from the Q-link resulting in a detachment and drop. |
| May 30, 2025 | Z-2031-2025 | — | open, classified | The Q-link 13 could allow for an improper attachment (false latching) of the Quick-Release Hook used on Sling Bars and other accessories. This could result in a critical injury from a patient fall as the false latched component may initially bear weight but can loosen from the Q-link resulting in a detachment and drop. |
| May 12, 2025 | Z-1964-2025 | — | open, classified | Baxter has identified a design issue which may cause the pump to detect the presence of a syringe flange when no syringe is loaded. When this issue occurs, the pumps 'user interface becomes stuck on the "Remove Syringe" screen when an infusion is complete, and the syringe is unloaded. A System Error 21502 (Flange Sensor Failure) may occur. Please note this issue only affects a subset of Novum IQ syringe pumps manufactured or repaired after July 4, 2023. |
| May 9, 2025 | Z-1962-2025 | — | open, classified | The replacement rechargeable batteries inserted into the Welch Allyn PocketScope handles have the potential to cause a short circuit in the handle, which can lead to exposure to excessive heat and user burns. |
| May 6, 2025 | Z-1816-2025 | — | open, classified | There is a potential for improper crimps on the signal wires of the actuators which could result in a loss of ability to lower the bed or the foot section of the bed. |
| Apr 24, 2025 | Z-1767-2025 | — | open, classified | There is a potential for the Novum IQ LVP due to the potential for underinfusion following use of the "standby mode" feature or if the device is powered off with the set loaded. |
| Apr 7, 2025 | Z-1726-2025 | — | open, classified | A cybersecurity vulnerability was discovered through internal testing. |
| Apr 7, 2025 | Z-1725-2025 | — | open, classified | A cybersecurity vulnerability was discovered through internal testing. |
| Mar 24, 2025 | Z-1559-2025 | — | open, classified | There were customer reports of devices which experienced battery-related fires. The investigation found that the devices in question were utilizing third-party, after-market batteries that are not approved by Baxter. |
| Mar 24, 2025 | Z-1558-2025 | — | open, classified | There were customer reports of devices which experienced battery-related fires. The investigation found that the devices in question were utilizing third-party, after-market batteries that are not approved by Baxter. |
| Mar 24, 2025 | Z-1560-2025 | — | open, classified | There were customer reports of devices which experienced battery-related fires. The investigation found that the devices in question were utilizing third-party, after-market batteries that are not approved by Baxter. |
| Mar 21, 2025 | Z-1564-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1566-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1568-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1565-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1562-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1567-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 21, 2025 | Z-1563-2025 | — | open, classified | Undeclared natural rubber band within the packaging of certain configurations of reusable blood pressure cuffs. |
| Mar 3, 2025 | Z-1423-2025 | — | open, classified | Baxter Healthcare Corporation is issuing an Urgent Medical Device Recall for the Novum IQ syringe pumps listed below due to an incorrectly installed gasket. A gasket failure could lead to potential fluid ingress due to cleaning, or as a result of an IV fluid spill. |
| Feb 25, 2025 | Z-1417-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1412-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1409-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1421-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1418-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1414-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1416-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1411-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1413-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1419-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1420-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1415-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1422-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1410-2025 | — | open, classified | There is a software issue which causes the upper back section to not be operable/adjustable when the "emergency mode" function is enabled. |
| Feb 25, 2025 | Z-1468-2025 | — | open, classified | The air bladders inside the mattress may move out of position when the head of the bed is elevated, causing a dip in the mattress. |
| Feb 5, 2025 | Z-1254-2025 | — | open, classified | There is the potential for missing motor mounting screws, which may have occurred during the servicing process. |
| Feb 5, 2025 | Z-1253-2025 | — | open, classified | There is the potential for missing motor mounting screws, which may have occurred during the servicing process. |
| Dec 20, 2024 | Z-1010-2025 | — | open, classified | Specific lots of Solution Sets with Duo-Vent Spike have the potential for inverted side clamps causing the tubing to be unusable. |
| Dec 20, 2024 | Z-1011-2025 | — | open, classified | Specific lots of Solution Sets with Duo-Vent Spike have the potential for inverted side clamps causing the tubing to be unusable. |
| Dec 20, 2024 | Z-0887-2025 | — | open, classified | There is an issue with the ventilator battery charger that could lead to an audible and visual alarm. If the alarm is engaged, the ventilator becomes inoperable. |
| Dec 20, 2024 | Z-0884-2025 | — | open, classified | There is an issue with the ventilator battery charger that could lead to an audible and visual alarm. If the alarm is engaged, the ventilator becomes inoperable. |
| Dec 20, 2024 | Z-0885-2025 | — | open, classified | There is an issue with the ventilator battery charger that could lead to an audible and visual alarm. If the alarm is engaged, the ventilator becomes inoperable. |
| Dec 20, 2024 | Z-1009-2025 | — | open, classified | Specific lots of Solution Sets with Duo-Vent Spike have the potential for inverted side clamps causing the tubing to be unusable. |
| Dec 20, 2024 | Z-0886-2025 | — | open, classified | There is an issue with the ventilator battery charger that could lead to an audible and visual alarm. If the alarm is engaged, the ventilator becomes inoperable. |
| Nov 19, 2024 | Z-0776-2025 | — | open, classified | Devices were identified as released after repair without full testing being performed, which includes flow testing. |
| Nov 19, 2024 | Z-0775-2025 | — | open, classified | Devices were identified as released after repair without full testing being performed, which includes flow testing. |
| Oct 23, 2024 | Z-0569-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0563-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0560-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0566-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0564-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0559-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0568-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0567-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0562-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0565-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 23, 2024 | Z-0561-2025 | — | open, classified | There has been an increase in the number of complaints related to the separation of the female connector from the main body of the transfer set. |
| Oct 21, 2024 | Z-0378-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0374-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0377-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0376-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0379-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0380-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0381-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0382-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0375-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 21, 2024 | Z-0373-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 16, 2024 | Z-0327-2025 | — | open, classified | Baxter is aware of several recalls by other manufacturers related to the potential risk of exposure to non-dioxin-like (NDL) polychlorinated biphenyl acids (PCBAs) and NDL polychlorinated biphenyls (PCBs) when using certain peritoneal dialysis and hemodialysis devices. |
| Oct 11, 2024 | Z-0322-2025 | — | open, classified | There is the potential for exam files being assigned duplicate Unique Identifiers (UIDs),. If the system receiving the DICOM file (e.g., Picture Archiving and Communication System (PACS)) relies solely on the UID to accept exams, this could lead to a mismatch of the patients identification with their physiological data. |
| Oct 11, 2024 | Z-0320-2025 | — | open, classified | There is the potential for exam files being assigned duplicate Unique Identifiers (UIDs),. If the system receiving the DICOM file (e.g., Picture Archiving and Communication System (PACS)) relies solely on the UID to accept exams, this could lead to a mismatch of the patients identification with their physiological data. |