Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

Belmont Instrument Corp.

US

Last updated May 23, 2026

What Belmont Instrument Corp. makes

Belmont Instrument Corp. manufactures medical devices for temperature regulation and fluid warming, including external circulating-fluid control units for heating and cooling, heat-exchanging intravenous sets, and extracorporeal hyperthermia applicators. Their portfolio also includes warming pumps for high-flow infusions, conduction blood/fluid warmers, and disposable or reusable temperature-sensing kits for adult and infant patients. Specific products include reusable and disposable warming blankets (e.g., ThermoWrap™), intravenous line kits, and a rapid infusion pump designed for high-volume fluid administration.

All listed devices fall under Class II regulatory classification in the US, requiring premarket notification (510(k)) or unique device identification (UDI) compliance. The company’s products are registered with the FDA under these pathways, and the manufacturer is based in the United States.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What medical devices does Belmont Instrument Corp. manufacture?

Belmont Instrument Corp. manufactures medical devices for temperature regulation and fluid warming, including external circulating-fluid control units, heat-exchanging intravenous sets, extracorporeal hyperthermia applicators, warming pumps for high-flow infusions, conduction blood/fluid warmers, and disposable or reusable temperature-sensing kits for adult and infant patients.

Where is Belmont Instrument Corp. based?

Belmont Instrument Corp. is based in the United States, as indicated by the country designation in the provided device data.

Which regulatory registries list Belmont Instrument Corp.'s devices?

Belmont Instrument Corp.'s devices are listed in the FDA 510(k) registry and the FDA Unique Device Identification (UDI) system, as specified in the device data.

How are Belmont Instrument Corp.'s devices classified?

All listed devices from Belmont Instrument Corp. fall under Class II regulatory classification in the US, requiring premarket notification (510(k)) or unique device identification (UDI) compliance, as stated in the device data.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
Website
—
LinkedIn
—
Facebook
—
Email
—
Phone
—
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
—

Catalogue (219)

Page 3 of 5
DeviceModel / ReferenceRegistriesClassStatus
Spanish, Rapid Infuser, 230 V, 750ml/min 903-00001A-S
FDA UDI
Class IIUnknown
Hyperthermia Pump Y-Set Pt Line, 4.4L Reservoir 902-00047P
FDA UDI
Class IIUnknown
CureWrap™ Pediatric 104–122cm (single) 500-03541
FDA UDI
Class IIActive
3.0 Liter Reservoir (1 Piece) 903-00018P
FDA UDI
Class IIActive
Chinese, Rapid Infuser, 230 V, 1000ml/min 903-00024-C
FDA UDI
Class IIUnknown
German, Rapid Infuser, 230 V, 1000ml/min 903-00024-G
FDA UDI
Class IIUnknown
Buddy Lite With Ac, Battery Housing And Heater Unit, European 905-00023
FDA UDI
Class IIUnknown
buddy, Power Module, 120 905-00003
FDA UDI
Class IIUnknown
Italian, Rapid Infuser RI-2, 230V, 1000 ml/min 903-00037A-I
FDA UDI
Class IIUnknown
CritiCool Mini 200-00336
FDA UDI
Class IIActive
Dual Patient Line (1 Piece) 903-00004P
FDA UDI
Class IIActive
buddy, 120V SYSTEM 905-00001-US-F
FDA UDI
Class IIUnknown
Italian, Rapid Infuser, 230 V, 750ml/min 903-00001A-I
FDA UDI
Class IIUnknown
CureWrap™ Adult Over 135 cm 500-03500
EUDAMEDFDA UDI
Class IIActive
ThermoWrap™ Universal 152-168cm (single) 500-03160
FDA UDI
Class IIActive
CureWrap™ Infant, 2.5-4Kg 500-03518
FDA UDI
Class IIActive
buddy, 230V SYSTEM 905-00001A-F-SW
FDA UDI
Class IIUnknown
Hyperthermia Pump St In/Out Pt Line 902-00039P
FDA UDI
Class IIUnknown
Chinese, Rapid Infuser, 230 V, 750ml/min 903-00001A-C
FDA UDI
Class IIUnknown
Swedish, Rapid Infuser, 230 V, 1000ml/min 903-00024-SW
FDA UDI
Class IIUnknown
UK, Rapid Infuser RI-2, 230V, 750 ml/min 903-00039A-UK
FDA UDI
Class IIUnknown
Norwegian, Rapid Infuser RI-2, 230V, 750 ml/min 903-00039A-N
FDA UDI
Class IIUnknown
Hyperthermia Pump Accessory Kit 902-00013
FDA UDI
Class IIActive
buddy, Power Module 403-00231
FDA UDI
Class IIUnknown
ThermoWrap™ Pediatric, 122–135cm, (single) 500-03148
FDA UDI
Class IIActive
Buddy Lite With Ac, Battery Housing And Heater Unit, Australia 905-00040
FDA UDI
Class IIUnknown
English, Rapid Infuser RI-2, 230V, 750 ml/min 903-00039A
FDA UDI
Class IIUnknown
German, Rapid Infuser RI-2, 230V, 1000 ml/min 903-00037A-G
FDA UDI
Class IIUnknown
buddy, Power Module, 230V 905-00003A
FDA UDI
Class IIUnknown
buddy 2 SYSTEM 905-00037-F
FDA UDI
Class IIUnknown
Spanish, Rapid Infuser RI-2, 230V, 1000 ml/min 903-00037A-S
FDA UDI
Class IIUnknown
Procedure Pack x1 902-00048P
FDA UDI
Class IIActive
buddy, 230V SYSTEM 905-00001A-G-SE
FDA UDI
Class IIUnknown
ThermoWrap™ Universal 135-152cm, (single) 500-03153
FDA UDI
Class IIActive
CureWrap™ Pediatric 91-104cm (single)
FDA UDI
Class IIUnknown
buddy, 230V SYSTEM 905-00001A-E-SE
FDA UDI
Class IIUnknown
Hyperthermia Pump Y-Set Pt Line Kit, w/ (2) 3L Reservoir 902-00005
FDA UDI
Class IIUnknown
CureWrap™ Infant, 7-11Kg, (single) 500-03525
FDA UDI
Class IIActive
Buddy Lite With Ac, Battery Housing And Heater Unit 403-00340AC
FDA UDI
Class IIUnknown
Rapid Infuser Accessory Kit 903-00013
FDA UDI
Class IIActive
The Belmont® Rapid Infuser FMS2000 903-00001
FDA UDI
Class IIUnknown
Buddy, Heater 403-00268
FDA UDI
Class IIUnknown
French, Hyperthermia Pump, 230V 902-00001A-F
FDA UDI
Class IIUnknown
Swedish, Rapid Infuser RI-2, 230V, 1000 ml/min 903-00037A-SW
FDA UDI
Class IIUnknown
buddy lite AC Blood/Fluid Warmer 905-00022
FDA UDI
Class IIActive
CureWrap™ Pediatric 104-122cm (single)
FDA UDI
Class IIUnknown
Norwegian, Rapid Infuser RI-2, 230V, 1000 ml/min 903-00037A-N
FDA UDI
Class IIUnknown
buddy 2 SYSTEM 905-00037-UK
FDA UDI
Class IIUnknown
buddy, 230V SYSTEM 905-00001A-F-SE
FDA UDI
Class IIUnknown
Spanish, Rapid Infuser, 230 V, 1000ml/min 903-00024-S
FDA UDI
Class IIUnknown

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (8)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Belmont Instrument Corp. has eight FDA recall records initiated between September 25, 2012, and May 13, 2025. The records include instances where the status is open, classified, or terminated. Reasons cited involve potential temperature control issues with the ThermoWrap patient wrap when alarms are disabled, leaks in connectors or sets during priming (affecting the Rapid Infuser or Allon device), premature pump failure causing a HALT 4 error, and a saline bag leak leading to an electrical flash near the power entry module.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
May 13, 2025Z-1966-2025—open, classified

An investigation into a report of the patient wrap (ThermoWrap), used with the Allon device, exceeding the set temperature determined that if: 1. The Human Sensor Board is disconnected from the Controller Board in the Allon device AND the temperature alarms are disabled, or 2. The Water In and Water Out and Thermostat sensors are disconnected from the Human Sensor Board AND the temperature alarms are disabled, the device will proceed to heat the water above the hardware fault limit without notifying the user of the faulty condition.

Mar 31, 2025Z-1674-2025—open, classified

Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser.

Mar 31, 2025Z-1675-2025—open, classified

Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser.

Mar 31, 2025Z-1676-2025—open, classified

Potential crack in the female connector located on the Heat Exchanger in the set, which will lead to a fluid leak through the crack during priming of the rapid infuser.

Mar 31, 2025Z-1678-2025—open, classified

Potential crack in the female connector located on the Heat Exchanger/patient line set, which will lead to a fluid leak through the crack during priming of the Rapid Infuser.

Jan 2, 2025Z-1099-2025—open, classified

Disposable set may leak during priming from a female quick connector due to a crack in the female quick connector, may lead to a potential delay in treatment since the set will need to be replaced by another set

Jul 20, 2021Z-0153-2023—open, classified

Premature pump failure may lead to the device displaying a HALT 4 error, from which the device cannot recover even after device reboot. The issue may potentially lead to delayed treatment and a failure to deliver the prescribed thermoregulation therapy. To date, the firm has received one report of death potentially related to this issue.

Sep 25, 2012Z-0058-2013—terminated

Leak from a saline bag caused saline to drip along the back of the Rapid infuser close to the Power Entry Module causing an electrical flash at the power entry area.