Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

BIOMET 3I, LLC

US

Last updated May 24, 2026

What BIOMET 3I, LLC makes

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal implants, both permanent and temporary suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, and bone taps.

The company's products are regulated as Class I and Class II medical devices and are listed in the FDA UDI registry. BIOMET 3I, LLC is based in the United States.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What does BIOMET 3I, LLC manufacture?

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal dental implants, both permanent and temporary dental implant suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, bone taps, and dental regeneration membranes.

Where is BIOMET 3I, LLC based?

BIOMET 3I, LLC is based in the United States, as indicated by the country information provided in the device data.

Which regulatory registries list BIOMET 3I, LLC's devices?

BIOMET 3I, LLC's devices are listed in the FDA UDI registry, which is the only registry mentioned in the provided device data for this company.

How are BIOMET 3I, LLC's devices classified?

BIOMET 3I, LLC's devices are regulated as Class I and Class II medical devices, with Class II being the most common classification for their dental implant products and related components.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
Website
biomet.com
LinkedIn
—
Facebook
—
Phone
+1(800)342-5454
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
186127825

Catalogue (2523)

Page 20 of 51
DeviceModel / ReferenceRegistriesClassStatus
Ep® TH263
FDA UDI
Class IIUnknown
Bellatek® Encode® EHA354
FDA UDI
Class IIActive
Certain® Bellatek® IEDAT5
FDA UDI
Class IIActive
Certain® ISWHA54
FDA UDI
Class IIActive
Osseotite® Certain® IOSS420
FDA UDI
Class IIActive
Certain® Locator® ILOA001
FDA UDI
Class IIActive
Osseotite® OSS320
FDA UDI
Class IIActive
Certain® IAC4425
FDA UDI
Class IIUnknown
Osseotite® NT585
FDA UDI
Class IIActive
Bellatek® Encode® EHA558
FDA UDI
Class IIActive
Osseotite® Certain® Prevail2 XIIOS5415
FDA UDI
Class IIUnknown
Certain® IIPDTUL
FDA UDI
Class IActive
Immediate Molar IMDR28SSP
FDA UDI
Class IActive
Immediate Molar IMDR811SP
FDA UDI
Class IActive
3i T3® BOSS513
FDA UDI
Class IIActive
Iol® IOL20T
FDA UDI
Class IIUnknown
3i T3® DCD® BNES3765
FDA UDI
Class IIActive
Certain® Bellatek® Encode® IEEHA467
FDA UDI
Class IIActive
Bellatek® TSVEDAZR3
FDA UDI
Class IIActive
Osseotite® Certain® Prevail2 XIIOS5411
FDA UDI
Class IIUnknown
Osseotite® 2 XTAP63S
FDA UDI
Class IActive
Navigator® SGD2A
FDA UDI
Class IActive
BellaTek® Encode® TEHA3503
FDA UDI
Class IIActive
Osseotite® Xp® FOS4585
FDA UDI
Class IIUnknown
Osseotite® Certain® XIFNT3210
FDA UDI
Class IIActive
Navigator® SGD325Z
FDA UDI
Class IActive
Certain® Gingihue® IWPP574G
FDA UDI
Class IIActive
Osseoguard® TR150SMT-1
FDA UDI
Class IIActive
Navigator® Certain® SGIAM41
FDA UDI
Class IActive
3i T3® BOES413
FDA UDI
Class IIActive
Navigator® Certain® SGIAM4L
FDA UDI
Class IActive
Navigator® SGTRAY
EUDAMEDFDA UDI
Class IActive
3i T3® DCD® BNES3711
FDA UDI
Class IIActive
3i T3® BOES685
FDA UDI
Class IIActive
Certain® PTT300I
EUDAMEDFDA UDI
Class IActive
Osseotite® 2 XFOS565
FDA UDI
Class IIActive
Navigator® SGTCD5L
FDA UDI
Class IActive
Driva™ Gold Series Drills SP44SG
FDA UDI
Class IActive
3i T3® BOPT5411
FDA UDI
Class IIActive
Bellatek® CSH10
FDA UDI
Class IIActive
Osseoguard® TR150RAK-1
FDA UDI
Class IIActive
Act® Short ACT206S
EUDAMEDFDA UDI
Class IActive
Driva™ Gold Series Drills SP38D34G
FDA UDI
Class IActive
Osseotite Nt® NTOST5A
EUDAMEDFDA UDI
Class IActive
Certain® Bellatek® Encode® IEHA453
FDA UDI
Class IIActive
Osseotite® FOS513
FDA UDI
Class IIActive
Unisystem™ PSKT20
FDA UDI
Class IActive
Certain® IWSU30
FDA UDI
Class IActive
Ep® WTH54
FDA UDI
Class IIActive
Certain® ILPC342
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (100)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Biomet 3i, LLC has 240 recall records initiated between 2006-12-11 and 2020-08-31, all with a status of terminated. The reasons for recall include mislabeling of packages, potential sterility issues, inadequate biocompatibility testing, seating problems, incorrect manufacturing of internal threads and hex features, drill malfunctions, reports of abutment fractures, and oversized copings.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Aug 31, 2020Z-0077-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0076-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0078-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0075-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0074-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0073-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0079-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Jan 10, 2020Z-1380-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1375-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1383-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1370-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1374-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1371-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1366-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1369-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1372-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1381-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1386-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1382-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1376-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1368-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1387-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1367-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1379-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1388-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1377-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1384-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1385-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1378-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1373-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Feb 26, 2019Z-2143-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2142-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2141-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2144-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2140-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Mar 8, 2017Z-1701-2017—terminated

A single lot of product that potentially has a single part within the lot that does not match the product on the label due to a commingle at the firm supplier

Sep 14, 2016Z-0835-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0831-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0860-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0849-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0841-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0836-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0846-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0861-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0848-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0854-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0857-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0862-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0847-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0838-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0842-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0830-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0844-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0845-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0856-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0855-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0851-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0852-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0850-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0829-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0853-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0834-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0859-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0833-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0840-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0828-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0843-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0837-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0863-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0839-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0832-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0858-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Aug 8, 2016Z-2845-2016—terminated

Product was incorrectly packaged.

Nov 25, 2015Z-2481-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2410-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2466-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2454-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2522-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2471-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2461-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2415-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2487-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2449-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2465-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2445-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2420-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2470-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2456-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2463-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2479-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2477-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2423-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2427-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2434-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2516-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2519-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2441-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2417-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2408-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2426-2016—terminated

Pouches may not have been sealed during packing.