Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

BIOMET 3I, LLC

US

Last updated May 24, 2026

What BIOMET 3I, LLC makes

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal implants, both permanent and temporary suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, and bone taps.

The company's products are regulated as Class I and Class II medical devices and are listed in the FDA UDI registry. BIOMET 3I, LLC is based in the United States.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What does BIOMET 3I, LLC manufacture?

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal dental implants, both permanent and temporary dental implant suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, bone taps, and dental regeneration membranes.

Where is BIOMET 3I, LLC based?

BIOMET 3I, LLC is based in the United States, as indicated by the country information provided in the device data.

Which regulatory registries list BIOMET 3I, LLC's devices?

BIOMET 3I, LLC's devices are listed in the FDA UDI registry, which is the only registry mentioned in the provided device data for this company.

How are BIOMET 3I, LLC's devices classified?

BIOMET 3I, LLC's devices are regulated as Class I and Class II medical devices, with Class II being the most common classification for their dental implant products and related components.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
Website
biomet.com
LinkedIn
—
Facebook
—
Phone
+1(800)342-5454
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
186127825

Catalogue (2523)

Page 34 of 51
DeviceModel / ReferenceRegistriesClassStatus
TSX® Immediate Molar IMKITTSXUNP
FDA UDI
Class IActive
T3 T3PT5413
FDA UDI
Class IIActive
Certain® ICA001
FDA UDI
Class IIUnknown
Certain® ICA055
FDA UDI
Class IIUnknown
Ep® MT236
FDA UDI
Class IIUnknown
Osseotite® NT615
FDA UDI
Class IIActive
Navigator® SGDPH1
FDA UDI
Class IActive
3i T3® DCD® BNSS485
FDA UDI
Class IIActive
Certain® IWCA54
FDA UDI
Class IIUnknown
Certain® Bellatek® Encode® IEEHA577
FDA UDI
Class IIActive
Certain® IPPMM1
FDA UDI
Class IActive
Osseotite Xp® Certain® IOS5613
FDA UDI
Class IIUnknown
Osseoguard® TR150TCS-N-1
FDA UDI
Class IIActive
3i T3® DCD® BNPS6511
FDA UDI
Class IIActive
Certain® Bellatek® Encode® IEEHA447
FDA UDI
Class IIActive
Certain® Ep® IWTH563
FDA UDI
Class IIActive
Ep® Twist Lock™ WIT67
FDA UDI
Class IActive
Navigator® SGD3Y
FDA UDI
Class IActive
Nanotite® NNT513
FDA UDI
Class IIUnknown
Ltx LTX613
FDA UDI
Class IIActive
Bellatek® 3MAT3
FDA UDI
Class IIActive
Certain® Provide® IPA6440
FDA UDI
Class IIUnknown
Certain® Ep® IWTH572
FDA UDI
Class IIActive
3i T3® DCD® BNST510
FDA UDI
Class IIActive
Osseotite® FOSM313
FDA UDI
Class IIActive
Unisystem™ PSKT30
FDA UDI
Class IActive
3i T3® BOES385
FDA UDI
Class IIActive
Osseotite® Certain® XIFNT613
FDA UDI
Class IIActive
Osseotite® Certain® 2 XIFOSS513
FDA UDI
Class IIActive
Bellatek® CSH07
FDA UDI
Class IIActive
Act® ACT3220
EUDAMEDFDA UDI
Class IActive
BellaTek® Encode® TEHA4605
FDA UDI
Class IIActive
Osseotite® Xp® Certain® IFOS5611
FDA UDI
Class IIUnknown
Osseotite Nt® NTOST3A
EUDAMEDFDA UDI
Class IActive
Navigator® SGSD4
FDA UDI
Class IActive
3i T3® DCD® BNSS313
FDA UDI
Class IIActive
TSX® Immediate Molar Implant TSXIM8D10L
FDA UDI
Class IIActive
Zimmer ZFX Abutment ZFX01000286
FDA UDI
Class IIActive
Bellatek® Encode® EHA564
FDA UDI
Class IIActive
Dríva™ Gold Series Drills TSV44D38SG
FDA UDI
Class IActive
BellaTek TE352
FDA UDI
Class IIActive
Ltx LTX611
FDA UDI
Class IIActive
Certain® ISRT10
FDA UDI
Class IUnknown
Certain® Ep® ITHA53
FDA UDI
Class IIActive
Osseoguard® TR250PW-2
FDA UDI
Class IIActive
Navigator® MSGTCDS
EUDAMEDFDA UDI
Class IActive
Osseotite® Xp® FOS5610
FDA UDI
Class IIUnknown
Osseotite® NT485
FDA UDI
Class IIActive
Certain® Ginighue® IMAP354G
FDA UDI
Class IIActive
Locator® LAELM
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (100)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Biomet 3i, LLC has 240 recall records initiated between 2006-12-11 and 2020-08-31, all with a status of terminated. The reasons for recall include mislabeling of packages, potential sterility issues, inadequate biocompatibility testing, seating problems, incorrect manufacturing of internal threads and hex features, drill malfunctions, reports of abutment fractures, and oversized copings.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Aug 31, 2020Z-0077-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0076-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0078-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0075-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0074-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0073-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0079-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Jan 10, 2020Z-1380-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1375-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1383-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1370-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1374-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1371-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1366-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1369-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1372-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1381-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1386-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1382-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1376-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1368-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1387-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1367-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1379-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1388-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1377-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1384-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1385-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1378-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1373-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Feb 26, 2019Z-2143-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2142-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2141-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2144-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2140-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Mar 8, 2017Z-1701-2017—terminated

A single lot of product that potentially has a single part within the lot that does not match the product on the label due to a commingle at the firm supplier

Sep 14, 2016Z-0835-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0831-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0860-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0849-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0841-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0836-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0846-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0861-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0848-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0854-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0857-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0862-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0847-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0838-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0842-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0830-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0844-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0845-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0856-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0855-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0851-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0852-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0850-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0829-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0853-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0834-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0859-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0833-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0840-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0828-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0843-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0837-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0863-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0839-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0832-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0858-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Aug 8, 2016Z-2845-2016—terminated

Product was incorrectly packaged.

Nov 25, 2015Z-2481-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2410-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2466-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2454-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2522-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2471-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2461-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2415-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2487-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2449-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2465-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2445-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2420-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2470-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2456-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2463-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2479-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2477-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2423-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2427-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2434-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2516-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2519-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2441-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2417-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2408-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2426-2016—terminated

Pouches may not have been sealed during packing.