Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

BIOMET 3I, LLC

US

Last updated May 24, 2026

What BIOMET 3I, LLC makes

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal implants, both permanent and temporary suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, and bone taps.

The company's products are regulated as Class I and Class II medical devices and are listed in the FDA UDI registry. BIOMET 3I, LLC is based in the United States.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What does BIOMET 3I, LLC manufacture?

BIOMET 3I, LLC manufactures dental implants and related products, including screw endosteal dental implants, both permanent and temporary dental implant suprastructure components, dental drill bits (reusable and single-use), surgical screwdrivers, bone taps, and dental regeneration membranes.

Where is BIOMET 3I, LLC based?

BIOMET 3I, LLC is based in the United States, as indicated by the country information provided in the device data.

Which regulatory registries list BIOMET 3I, LLC's devices?

BIOMET 3I, LLC's devices are listed in the FDA UDI registry, which is the only registry mentioned in the provided device data for this company.

How are BIOMET 3I, LLC's devices classified?

BIOMET 3I, LLC's devices are regulated as Class I and Class II medical devices, with Class II being the most common classification for their dental implant products and related components.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
Website
biomet.com
LinkedIn
—
Facebook
—
Phone
+1(800)342-5454
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
186127825

Catalogue (2523)

Page 40 of 51
DeviceModel / ReferenceRegistriesClassStatus
Certain® ISC4
FDA UDI
Class IActive
T3® PRO Immediate Molar IMT3PTAPSUNP
FDA UDI
Class IActive
Certain® Twist Lock™ IWIT66
FDA UDI
Class IActive
3i T3® DCD® BNPT4385
FDA UDI
Class IIActive
Osseotite® Certain® XIFNT411
FDA UDI
Class IIActive
Osseotite® Certain® IFNT513
FDA UDI
Class IIActive
Certain® Provide® PAK4455
FDA UDI
Class IIUnknown
Certain® Ep® IWTH58
FDA UDI
Class IIActive
Osseotite® NT3285
FDA UDI
Class IIActive
3i T3® BOST413
FDA UDI
Class IIActive
Ep® Twist Lock™ CIC57
FDA UDI
Class IActive
Nanotite™ Certain® NIOSS410
FDA UDI
Class IIUnknown
Osseotite® FNT3285
FDA UDI
Class IIActive
3i T3® BOPT5415
FDA UDI
Class IIActive
Gingihue® WPP554G
FDA UDI
Class IIActive
Certain® Bellatek® Encode® IEEHA455
FDA UDI
Class IIActive
Tsv® Bellatek® Encode® TEEHA353
FDA UDI
Class IIActive
Certain® IIPDTL
FDA UDI
Class IActive
Certain® QNTSK40
FDA UDI
Class IActive
Navigator® SGTT515L
FDA UDI
Class IActive
Certain® IRORDR
FDA UDI
Class IActive
3i T3® BOES611
FDA UDI
Class IIActive
Immediate Molar IMDR711SP
FDA UDI
Class IActive
Preformance® WPFTC61
FDA UDI
Class IIActive
Bellatek® TSVLDAZR3
FDA UDI
Class IIActive
Certain® Ep® ITHA66
FDA UDI
Class IIActive
Certain® Ep® IWTH63
FDA UDI
Class IIActive
3i T3® BOES315
FDA UDI
Class IIActive
Bellatek® Encode® EHA446
FDA UDI
Class IIActive
Bellatek® 3MAN6
FDA UDI
Class IIActive
Osseotite® Certain® IOSS685
FDA UDI
Class IIActive
Immediate Molar IMDI8
FDA UDI
Class IActive
Osseotite Nt® NTDI413
EUDAMEDFDA UDI
Class IActive
Nanotite® NOSS407
FDA UDI
Class IIUnknown
Bellatek® Encode® EHA344
FDA UDI
Class IIActive
Nanotite™ Certain® NINT513
FDA UDI
Class IIActive
Osseotite® FNT511
FDA UDI
Class IIActive
Certain® ILPC541U
FDA UDI
Class IIActive
Osseotite® NT611
FDA UDI
Class IIActive
Bellatek® Encode® EHA666
FDA UDI
Class IIActive
Ltx LTX410
FDA UDI
Class IIActive
Osseoguard® TR250LF-2
FDA UDI
Class IIActive
Bellatek® TSVLDAT4
FDA UDI
Class IIActive
3i T3® DCD® BNPT4313
FDA UDI
Class IIActive
Osseotite® OSS511
FDA UDI
Class IIActive
Osseotite Nt® NTDI3211
EUDAMEDFDA UDI
Class IActive
Osseotite® FNT685
FDA UDI
Class IIActive
Immediate Molar IMDR44TSX
FDA UDI
Class IActive
BellaTek® Encode® TEHA5683
FDA UDI
Class IIActive
Nanotite™certain®prevail® NIIOS4310
FDA UDI
Class IIUnknown

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (100)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Biomet 3i, LLC has 240 recall records initiated between 2006-12-11 and 2020-08-31, all with a status of terminated. The reasons for recall include mislabeling of packages, potential sterility issues, inadequate biocompatibility testing, seating problems, incorrect manufacturing of internal threads and hex features, drill malfunctions, reports of abutment fractures, and oversized copings.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Aug 31, 2020Z-0077-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0076-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0078-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0075-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0074-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0073-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Aug 31, 2020Z-0079-2021—terminated

Hex of the BellaTek Encode Definitive Abutments was misaligned by 30 degrees during manufacturing as compared with the provided patient scan data (Images may cause misalignment, the definitive abutment will not seat in the correct orientation upon attempted placement with the patient

Jan 10, 2020Z-1380-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1375-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1383-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1370-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1374-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1371-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1366-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1369-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1372-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1381-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1386-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1382-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1376-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1368-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1387-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1367-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1379-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1388-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1377-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1384-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1385-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1378-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Jan 10, 2020Z-1373-2020—terminated

Resulting impression or scanned data produced from the Healing Abutment lots will result in an incorrect rotation of approximately 30 degrees and/or margin contour misalignment

Feb 26, 2019Z-2143-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2142-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2141-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2144-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Feb 26, 2019Z-2140-2019—terminated

During manufacturing, the screw stop ledge was not made to specification and location within the abutment, resulting in the screw head seating deeper in the abutment with no positive stop.

Mar 8, 2017Z-1701-2017—terminated

A single lot of product that potentially has a single part within the lot that does not match the product on the label due to a commingle at the firm supplier

Sep 14, 2016Z-0835-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0831-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0860-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0849-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0841-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0836-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0846-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0861-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0848-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0854-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0857-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0862-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0847-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0838-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0842-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0830-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0844-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0845-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0856-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0855-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0851-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0852-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0850-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0829-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0853-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0834-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0859-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0833-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0840-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0828-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0843-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0837-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0863-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0839-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0832-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Sep 14, 2016Z-0858-2017—terminated

A limited number of product pouches may not have been sealed during packaging.

Aug 8, 2016Z-2845-2016—terminated

Product was incorrectly packaged.

Nov 25, 2015Z-2481-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2410-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2466-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2454-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2522-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2471-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2461-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2415-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2487-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2449-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2465-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2445-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2420-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2470-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2456-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2463-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2479-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2477-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2423-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2427-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2434-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2516-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2519-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2441-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2417-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2408-2016—terminated

Pouches may not have been sealed during packing.

Nov 25, 2015Z-2426-2016—terminated

Pouches may not have been sealed during packing.