Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

BIOMET SPINE LLC

US

Last updated May 24, 2026

What BIOMET SPINE LLC makes

Biomet Spine LLC manufactures spinal fixation systems, including bone-screw and trans-facet-screw internal fixation devices for both sterile and non-sterile use, as well as polymeric spinal interbody and fusion cages. Their portfolio also includes vertebral body prostheses, interspinous spinal fixation implants, and trial spinal implants designed for surgical applications. Systems like the Timberline Lateral Fusion System and Vital™ MIS Spinal Fixation System are tailored for lateral and minimally invasive spinal procedures, respectively.

The company’s devices are regulated under FDA classifications, including Class I, Class II, and Unclassified (U) devices, and are listed in the FDA’s Unique Device Identifier (UDI) database. The manufacturer operates within the United States, adhering to applicable U.S. regulatory requirements for spinal implants and fixation systems.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What types of medical devices does Biomet Spine LLC manufacture?

Biomet Spine LLC specializes in spinal fixation and reconstruction devices. Their portfolio includes bone-screw and trans-facet-screw internal fixation systems (both sterile and non-sterile), polymeric spinal interbody and fusion cages, vertebral body prostheses, interspinous spinal fixation implants, and trial spinal implants. These devices are designed for surgical applications to stabilize, fuse, or replace spinal segments, such as systems like the Timberline Lateral Fusion System for lateral procedures or the Vital™ MIS Spinal Fixation System for minimally invasive surgeries.

Where is Biomet Spine LLC based, and how does that affect its regulatory oversight?

Biomet Spine LLC is based in the United States. Since it operates within the U.S., its devices are subject to FDA regulatory requirements, including classification under FDA categories such as Class I, Class II, or Unclassified (U). The company’s devices are also listed in the FDA’s Unique Device Identifier (UDI) database, ensuring traceability and compliance with U.S. medical device regulations.

Which regulatory registries or databases list Biomet Spine LLC’s devices?

Biomet Spine LLC’s devices are listed in the FDA’s Unique Device Identifier (UDI) database. This registry ensures transparency and allows healthcare providers, regulators, and other stakeholders to identify and track the company’s authorized spinal fixation and reconstruction products, including systems like the Silverton-D® Deformity System or the ALTIUS M-INI OCT Spine System.

How are Biomet Spine LLC’s devices classified under U.S. regulations?

Biomet Spine LLC’s devices fall under different FDA classifications depending on their risk and intended use. For example, bone-screw fixation systems may be classified as Class II due to their moderate risk, while simpler devices like certain polymeric spinal cages might qualify as Class I. Some devices, such as specialized trial implants, may be Unclassified (U) pending further regulatory evaluation. Classification determines the regulatory pathway and requirements for authorization.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
LinkedIn
—
Facebook
—
Phone
+1(800)447-3625
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
018577570

Catalogue (32639)

Page 13 of 500
DeviceModel / ReferenceRegistriesClassStatus
Silverton-D Deformity System 7722-8585
FDA UDI
Class IIActive
Concero Facet Screw System 7514-4537
FDA UDI
UActive
Polaris 5.5 Spinal System 14-500376
FDA UDI
Class IIActive
Ballista(tm) Percutaneous Pedicle Screw System 14-500630
FDA UDI
Class IIActive
Silverton-D® Deformity System 7722-5550
FDA UDI
Class IIActive
Silverton-D® Deformity System 7718-6540
FDA UDI
Class IIActive
Lineum® OCT 14-525142E
FDA UDI
Class IIActive
Altius™ M-Ini™ Spinal System 1200-1220
FDA UDI
Class IIActive
Lineum® Oct Spine System 14-524509
FDA UDI
Class IIActive
Vitality® 701M6530
FDA UDI
Class IIActive
Polaris™ 4.75 14-587613CL
FDA UDI
Class IIActive
Polaris™ 5.5 Spinal System 2000-5114
FDA UDI
Class IIActive
Polaris™ 4.75 Spinal System 14-582120
FDA UDI
Class IIActive
Spinal System 132M2125
FDA UDI
Class IActive
Polaris™ 5.5 Spinal System 14-503160
FDA UDI
Class IIActive
Polaris™ 5.5 Spinal System 14-578307R
FDA UDI
Class IIActive
Ballista® Percutaneous 2000-3540E
FDA UDI
Class IIActive
Polaris™ 6.35 Spinal System 14-513265R
FDA UDI
Class IIActive
Lineum® OCT Spine System 14-524214
FDA UDI
Class IIActive
Vital™ 812M9085
FDA UDI
Class IIActive
Vital™ 806M8575
FDA UDI
Class IIActive
Lineum® Oct Spine System 14-524516
FDA UDI
Class IIActive
Polaris™ 6.35 Spinal System 14-573875
FDA UDI
Class IIActive
Polaris™ 4.75 Spinal System 14-582045
FDA UDI
Class IIActive
Timberline Lateral Fusion System 8703-2508
FDA UDI
Class IIActive
Alta Stand-Alone Interbody Fusion System 8409-1105
FDA UDI
Class IIActive
Silverton-D Deformity System 7722-8520
FDA UDI
Class IIActive
Spinal Fixation System 7701-0080
FDA UDI
Class IIActive
C-Thru Lordotic Anterior Spinal Sys 55001906
FDA UDI
Class IIActive
Polaris (tm) 5.5 Spinal System 14-502640
FDA UDI
Class IIActive
Vitality® 07.02025.029
FDA UDI
Class IIActive
Durango® Stand-Alone ALIF System 8509-0012
FDA UDI
Class IIActive
Vital™ 807M5525
FDA UDI
Class IIActive
Polaris 4.75 Ti Spinal System 14-583046
FDA UDI
Class IIActive
Timberline Lateral Fusion System 8703-4020
FDA UDI
Class IIActive
Alta Stand-Alone Interbody Fusion System 8409-2106
FDA UDI
Class IIActive
Polaris 4.75 Ti Spinal System 14-584136
FDA UDI
Class IIActive
Concero™ Facet Screw System 7514-3535
FDA UDI
UActive
Polaris™ 4.75 Spinal System 14-563627
FDA UDI
Class IIActive
Polaris™ 4.75 Spinal System 14-563927
FDA UDI
Class IIActive
MaxAn® Anterior Cervical Plate System 14-522200
FDA UDI
Class IIActive
Polaris™ 5.5 Spinal System 14-578380
FDA UDI
Class IIActive
Zyston® Strut 101M2108
FDA UDI
Class IIActive
Polaris 4.75 Spinal System 14-562766
FDA UDI
Class IIActive
C-Tek® Maxan® Anterior Cervical Plate System 14-522130
FDA UDI
Class IIActive
Gallery™ Laminoplasty System 14-523099
FDA UDI
Class IIActive
Array® Spinal System 94385J
FDA UDI
Class IIActive
Vitality®+ Osteotomy 732M3221
FDA UDI
Class IActive
Polaris 4.75 Spinal System 14-562541
FDA UDI
Class IIActive
Polaris™ 6.35 Spinal System 14-513870
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (14)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Biomet Spine LLC has 14 FDA recall records initiated between March 9, 2011, and February 12, 2016, all marked as terminated. The reasons include dimensional inconsistencies in components such as sleeves, drills, and screws (e.g., undersized or oversized diameters), mislabeling of product identifiers or dimensions, non-compliance with internal specifications for fatigue strength, and incomplete design control activities. Additional recalls involved supplier withdrawals for component updates, incorrect lordotic angle labeling, and missing locking features in surgical instruments.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Feb 12, 2016Z-1253-2016—terminated

Zimmer Biomet Spine initiated a recall of certain Solitaire Ti Spacers because they may have a mislabeled lordotic angle of 12degrees when the angle is actually 6 degrees.

Sep 29, 2015Z-0203-2016—terminated

The packaging of 4.5 mm diameter MaxAn screws identifies/labels the screws as 4.0 mm diameter screws.

Aug 5, 2015Z-2744-2015—terminated

Some of P/N 14-521614B Lot 375440 was mislabeled as P/N 14-521614 Lot 375440.

Jul 22, 2015Z-2759-2015—terminated

Biomet has initiated a recall on Biomet Spine Lineum OCC Starter Flexible and its inner shaft instrumentsafter identifying that these instruments were distributed prior to completion of all design control activities.

Mar 12, 2015Z-1465-2015—terminated

Biomet is recalling the Lineum HF Torque Handle Limit (Lineum) and Torque Limiting Handle (Aspen/ Alpine) due to the supplier withdrawing it from the market for component updates or reconfiguration.

Mar 12, 2015Z-1466-2015—terminated

Biomet is recalling the Lineum HF Torque Handle Limit (Lineum) and Torque Limiting Handle (Aspen/ Alpine) due to the supplier withdrawing it from the market for component updates or reconfiguration.

Mar 12, 2015Z-2152-2015—terminated

Multiaxial screws may not meet internal requirements related to fatigue strength. Compression testing result and surface treatment are out of specification.

Aug 22, 2013Z-0983-2015—terminated

The inner diameter of the Sleeve shaft is undersized, resulting in interference fit when inserting the Anchored Lateral Straight Retractable Awl or the Anchored Lateral Straight Retractable Drill into the Sleeve.

Aug 22, 2013Z-0978-2015—terminated

The inner diameter of the Sleeve shaft is undersized, resulting in interference fit when inserting the Anchored Lateral Straight Retractable Awl or the Anchored Lateral Straight Retractable Drill into the Sleeve shaft.

Aug 22, 2013Z-0982-2015—terminated

The outer diameter of the Drill shaft is oversized; thereby, resulting in interference fit when inserting the Drill into the Fixed or Variable Sleeve Assembly.

Nov 30, 2012Z-1146-2015—terminated

Biomet Spine LLC is recalling the Set Screw 5.5 mm Rod due to the set screw being out of specification

Feb 22, 2012Z-1069-2015—terminated

Biomet Spine, LLC is recalling the Timberline Cranial Caudal and Posterior Blades, 40-180mm due to oversize of the set screw hex feature.

Dec 19, 2011Z-1089-2015—terminated

The Telluride Percutaneous Rod Inserter Long does not contain a feature that locks the Rod in place during use. There is a potential for the Rod to disengage from the Inserter during insertion, and could lead to harm to the patient.

Mar 9, 2011Z-0220-2015—terminated

Biomet Spine, LLC. announces voluntary recall of Durango Anchored ALIF Plate due to the set screw component potentially becoming dislodged from the plate assembly.