# CliniSys, Inc

> Medical device manufacturer record on deviCERTS, compiled from public registries. CliniSys, Inc is a medical device manufacturer, with 70 devices listed in FDA GUDID (FDA Class I and II) and 48 FDA recalls as of 19 Nov 2026.

- Canonical page: <https://devicerts.com/manufacturers/clinisys-inc>
- Country: United States (from the FDA registration address)
- Role: Manufacturer
- Registrations: FDA
- FDA FEI: 1000306472
- DUNS: 052934841

## Figures

- Devices: 70
- FDA recalls (matched to the firm by name): 48

## Registry facts

*Every device of the manufacturer. A device listed in two registries counts in both.*

- Registries: FDA GUDID 70
- Device classes: FDA Class I 50, FDA Class II 20

## Devices

The first 50 of 70, in the order of the canonical page, which lists them all.

- [Clinisys Atlas 2025.2](https://devicerts.com/devices/clinisys-atlas-2025-2) · Class I · GUDID · status: Listed
- [Clinisys Atlas 2025.1](https://devicerts.com/devices/clinisys-atlas-2025-1) · Class I · GUDID · status: Listed
- [Clinisys Laboratory Solution 2025.2](https://devicerts.com/devices/clinisys-laboratory-solution-2025-2) · Class I · GUDID · status: Listed
- [Clinisys Laboratory Solution 2025.3](https://devicerts.com/devices/clinisys-laboratory-solution-2025-3) · Class I · GUDID · status: Listed
- [Clinisys CoPathPlus 8.0.3](https://devicerts.com/devices/clinisys-copathplus-8-0-3) · Class I · GUDID · status: Listed
- [Clinisys SQ Blood Bank 2024.2](https://devicerts.com/devices/clinisys-sq-blood-bank-2024-2) · Class II · GUDID · status: Active
- [Clinisys SQ Lab 2024.2](https://devicerts.com/devices/clinisys-sq-lab-2024-2) · Class I · GUDID · status: Listed
- [Clinisys SQ Blood Bank 2024.1](https://devicerts.com/devices/clinisys-sq-blood-bank-2024-1) · Class II · GUDID · status: Active
- [Sunquest PowerPath 13.0](https://devicerts.com/devices/sunquest-powerpath-13-0) · Class I · GUDID · status: Listed
- [Clinisys Atlas 2023.3](https://devicerts.com/devices/clinisys-atlas-2023-3) · Class I · GUDID · status: Listed
- [Sunquest Blood Bank 8.2.2](https://devicerts.com/devices/sunquest-blood-bank-8-2-2) · Class II · GUDID · status: Withdrawn
- [Sunquest Mitogen LIMS 4.1](https://devicerts.com/devices/sunquest-mitogen-lims-4-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Application Interfacing 5.3](https://devicerts.com/devices/sunquest-application-interfacing-5-3) · Class I · GUDID · status: Withdrawn
- [Clinisys Atlas 2023.4](https://devicerts.com/devices/clinisys-atlas-2023-4) · Class I · GUDID · status: Listed
- [Sunquest Instrument Interfacing 3.2](https://devicerts.com/devices/sunquest-instrument-interfacing-3-2) · Class I · GUDID · status: Withdrawn
- [Sunquest Mitogen Genetics 6.3](https://devicerts.com/devices/sunquest-mitogen-genetics-6-3) · Class I · GUDID · status: Withdrawn
- [Clinisys Atlas 2023.1](https://devicerts.com/devices/clinisys-atlas-2023-1) · Class I · GUDID · status: Listed
- [Sunquest CoPathPlus 7.1](https://devicerts.com/devices/sunquest-copathplus-7-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 11.0.2](https://devicerts.com/devices/sunquest-laboratory-11-0-2) · Class I · GUDID · status: Withdrawn
- [Sunquest Mitogen LIMS 4.0](https://devicerts.com/devices/sunquest-mitogen-lims-4-0) · Class I · GUDID · status: Withdrawn
- [Clinisys Laboratory Solutions 2023.2](https://devicerts.com/devices/clinisys-laboratory-solutions-2023-2-93f964ff) · Class I · GUDID · status: Listed
- [Sunquest Blood Bank 10.0](https://devicerts.com/devices/sunquest-blood-bank-10-0) · Class II · GUDID · status: Active
- [Sunquest Laboratory 8.2.3](https://devicerts.com/devices/sunquest-laboratory-8-2-3) · Class I · GUDID · status: Withdrawn
- [Sunquest Transfusion Manager 3.0](https://devicerts.com/devices/sunquest-transfusion-manager-3-0) · Class II · GUDID · status: Active
- [Sunquest Blood Bank 8.2.3](https://devicerts.com/devices/sunquest-blood-bank-8-2-3) · Class II · GUDID · status: Active
- [Sunquest Blood Bank 10.1](https://devicerts.com/devices/sunquest-blood-bank-10-1) · Class II · GUDID · status: Active
- [Sunquest Laboratory 10.1](https://devicerts.com/devices/sunquest-laboratory-10-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Mitogen LIMS 3.4](https://devicerts.com/devices/sunquest-mitogen-lims-3-4) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 8.0.1](https://devicerts.com/devices/sunquest-laboratory-8-0-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Blood Bank 10.0.1](https://devicerts.com/devices/sunquest-blood-bank-10-0-1) · Class II · GUDID · status: Active
- [Sunquest Atlas 2022.1 MR1](https://devicerts.com/devices/sunquest-atlas-2022-1-mr1) · Class I · GUDID · status: Listed
- [Sunquest Blood Bank 8.1.3](https://devicerts.com/devices/sunquest-blood-bank-8-1-3) · Class II · GUDID · status: Active
- [Sunquest Application Manager 7.1.2](https://devicerts.com/devices/sunquest-application-manager-7-1-2) · Class I · GUDID · status: Withdrawn
- [Sunquest Application Manager 7.1.1](https://devicerts.com/devices/sunquest-application-manager-7-1-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 10.1.1](https://devicerts.com/devices/sunquest-laboratory-10-1-1) · Class I · GUDID · status: Withdrawn
- [Clinisys Laboratory Solutions 2023.1](https://devicerts.com/devices/clinisys-laboratory-solutions-2023-1) · Class I · GUDID · status: Listed
- [Clinisys Laboratory Solutions 2023.1.4](https://devicerts.com/devices/clinisys-laboratory-solutions-2023-1-4) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 10.0](https://devicerts.com/devices/sunquest-laboratory-10-0) · Class I · GUDID · status: Withdrawn
- [Sunquest Blood Bank 11.0.1](https://devicerts.com/devices/sunquest-blood-bank-11-0-1) · Class II · GUDID · status: Active
- [Clinisys SQ Blood Bank 11.0.3](https://devicerts.com/devices/clinisys-sq-blood-bank-11-0-3) · Class II · GUDID · status: Active
- [Sunquest Transfusion Manager 2.2.0](https://devicerts.com/devices/sunquest-transfusion-manager-2-2-0) · Class II · GUDID · status: Withdrawn
- [Sunquest Blood Bank 11.0](https://devicerts.com/devices/sunquest-blood-bank-11-0) · Class II · GUDID · status: Active
- [Clinisys Atlas 2023.5](https://devicerts.com/devices/clinisys-atlas-2023-5) · Class I · GUDID · status: Listed
- [Clinisys Laboratory Solution 2023.3](https://devicerts.com/devices/clinisys-laboratory-solution-2023-3) · Class I · GUDID · status: Listed
- [Sunquest Blood Bank 8.2.1](https://devicerts.com/devices/sunquest-blood-bank-8-2-1) · Class II · GUDID · status: Withdrawn
- [Sunquest Atlas 2022.1](https://devicerts.com/devices/sunquest-atlas-2022-1) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 8.1.3](https://devicerts.com/devices/sunquest-laboratory-8-1-3) · Class I · GUDID · status: Withdrawn
- [Sunquest Laboratory 11.0](https://devicerts.com/devices/sunquest-laboratory-11-0) · Class I · GUDID · status: Withdrawn
- [Sunquest Blood Bank 8.0.1](https://devicerts.com/devices/sunquest-blood-bank-8-0-1) · Class II · GUDID · status: Active
- [Sunquest Mitogen LIMS 3.4.1](https://devicerts.com/devices/sunquest-mitogen-lims-3-4-1) · Class I · GUDID · status: Withdrawn

## FDA recalls (matched by name, newest first)

- Z-2332-2012 · Class II · Terminated · initiated 2012-03-15 · product code JQP: Sunquest is recalling Sunquest Laboratory versions 6.1.0125 through 6.1.0139, 6.2.1, 6.2.2, 7.0, and 7.0.1 because when the Windows-based merge application is used and the "Event merge across patients" option is used, a receiving system (for example a HIS or CoPath system) may interpret the event merge as a full patient merge. This occurs because a trigger from the Laboratory system for the event
- Z-2270-2012 · Class II · Terminated · initiated 2011-12-05 · product code JQP: The recall was initiated because Sunquest has confirmed that the Sunquest Laboratory versions 6.4 and later while using Microbiology Result Entry (MRE), the specimen ribbon containing the Accession Number (AN) and the Battery Name may be missing or contain the wrong information.
- Z-0073-2013 · Class III · Terminated · initiated 2011-11-15 · product code JQP: Online calculations may not be performed as expected or may yield results that are different than expected when the calculation module is called from the Online Entry (OEM) application for a subtest whose subcolumn number on the instrument online string is divisible by 10.
- Z-0250-2013 · Class II · Terminated · initiated 2011-11-03 · product code JQP: Sunquest is recalling Sunquest Laboratory version 7.0 because when saving an Accession to a non-current Episode/Event, a User-Defined field can be incorrectly replaced by the current Episode/Event User-Defined data.
- Z-2229-2012 · Class III · Terminated · initiated 2011-08-12 · product code JQP: In GUI inquiry, searching by ID (CID) may return the wrong patient demographic data if the accession number associated to the CID is no longer inactive.
- Z-2216-2012 · Class III · Terminated · initiated 2011-04-28 · product code JQP: In Online Entry (OEx) there are two scenarios where a Test result from one container may file to a Test on another container. In order for this to occur: 1) Site parameter SIT 1,2,1,26 (3,217) \[Restrict resulting of tests to owner container (/N)\]=Y. 2) The Tests are ordered on the same accession number and 3) The Test codes are defined to have the same upload code as either replicate or
- Z-2272-2012 · Class II · Terminated · initiated 2010-10-05 · product code JQP: The recall was initiated because Sunquest has confirmed that the Sunquest Laboratory LabAccess Results Workstation (LARS) may file results to the wrong patient by incorrectly combining results.
- Z-0251-2013 · Class II · Terminated · initiated 2009-11-19 · product code JQP: The recall was initiated because Sunquest Information System has confirmed reports of an Outbound Phlebotomy Point of Care (POC) interface is combining patient orders inappropriately.
- Z-2243-2012 · Class III · Terminated · initiated 2009-04-13 · product code JQP: Sunquest is recalling the Sunquest Encompass versions 2.4 and later because the specimen collect time is displaying and printing one hour later than the actual collect time only when Daylight Saving Time is active.
- Z-0214-2009 · Unclassified (pre-2012) · Terminated · initiated 2008-08-01 · product code JQP: While performing in-house testing for the Sunquest Laboratory System and under certain conditions, there have been instances in which an error that occurred at the database level or originated in the operating system (Cache)was not communicated or displayed in the Graphic User Interface (GUI) application so the activity continued. While this error was registered in the error log in the System U
- Z-0207-2009 · Unclassified (pre-2012) · Terminated · initiated 2008-04-17 · product code JQP: Sunquest has identified a problem with IGO interfaces when performing an Online File Cleanup (OFC) that can lead to the test results of one patient filing to another patient when the order codes are the same. Performing an OFC prior to all results being assigned an accession number may cause the patient results to remain in a temporary file where they can be incorrectly associated to the wrong pat
- Z-0088-06 · Unclassified (pre-2012) · Terminated · initiated 2005-09-29 · product code JQP: Customer complaint during testing of module prior to production use. Software problem when the user has indicated to enter a coded comment instead of using the defined keyboard, then enters 100,000, the system willfile the number 100 instead of number 100,000.
- Z-0938-05 · Unclassified (pre-2012) · Terminated · initiated 2005-05-13 · product code JQP: Software anomaly may rarely allow modification of previously reported specimen results.
- Z-0939-05 · Unclassified (pre-2012) · Terminated · initiated 2005-05-10 · product code JQP: When a previously reported microbiology organism result is deleted on a selected patient, reported susceptibilities will not stay with associated organisms and one or more suceptibilities on the culture will be deleted.
- Z-0235-04 · Unclassified (pre-2012) · Terminated · initiated 2003-09-25 · product code JQP: Software Defect. When orders are modified before the Roche Cobas Integra query for a specimen, the sample ID locks.
- Z-0007-04 · Unclassified (pre-2012) · Terminated · initiated 2003-08-12 · product code JQP: Software defect. Clinical Laboratory results failing quality assurance were filed directly to a patient's chart without review.
- Z-1220-03 · Unclassified (pre-2012) · Terminated · initiated 2003-07-24 · product code JQP: Software Design Defect. Under certain conditions, results are removed.
- Z-1240-03 · Unclassified (pre-2012) · Terminated · initiated 2003-07-23 · product code JQP: Software Defect. Data used in the diagnosis and or treatment of a patient's illness are missing from the patient result report.
- Z-1217-03 · Unclassified (pre-2012) · Terminated · initiated 2003-07-22 · product code JQP: Software design deficiency. If the dilution factor is added to the same result twice, incorrect specimen values are reported.
- Z-0238-04 · Unclassified (pre-2012) · Terminated · initiated 2003-07-21 · product code JQP: Incorrect demographics display which can result in incorrect information being used in diagnosis or treatment of patients.
- Z-0151-04 · Unclassified (pre-2012) · Terminated · initiated 2003-07-07 · product code JQP: Software defect causes orders to be lost under certain conditions of use. A typographical error at the Accept/Modfy/Reject prompt will cause the order not to be processed by the system.
- Z-1092-03 · Unclassified (pre-2012) · Terminated · initiated 2003-07-02 · product code JQP: Patient files become mixed up due to a software defect.
- Z-1093-03 · Unclassified (pre-2012) · Terminated · initiated 2003-06-23 · product code JQP: Software defect. When Quality Assurance failure warnings are missing from a patient's report abnormal results could be used for diagnosis or treatment.
- Z-1090-03 · Unclassified (pre-2012) · Terminated · initiated 2003-06-16 · product code JQP: Software anomaly allows patient reports to contain incomplete data used for diagnosis or treatment.
- Z-1007-03 · Unclassified (pre-2012) · Terminated · initiated 2003-06-10 · product code JQP: Software anomally Results with a global flag failure that autofile without review can cause abnormal results being communicated without associated abnormal designations.

## Source and citation

- Cite as: CliniSys, Inc. deviCERTS medical device catalogue. https://devicerts.com/manufacturers/clinisys-inc (data as of 2026-11-19).
- Data sources: [FDA GUDID](https://accessgudid.nlm.nih.gov/), [FDA registration and listing](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfrl/rl.cfm), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- FDA recall data as of: 2026-11-01
- Data as of: 2026-11-19
- JSON: <https://devicerts.com/manufacturers/clinisys-inc.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/manufacturers/clinisys-inc
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.