Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

ACUMED LLC

US

Last updated September 17, 2026

Information

Country
US
Address
5885 NE Cornelius Pass Rd, Hillsboro, OR, 97124
Website
—
LinkedIn
—
Facebook
—
Email
—
Phone
—
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
1000125930
DUNS Number
—

Catalogue (6937)

Page 9 of 139
DeviceModel / ReferenceRegistriesClassStatus
Acumed 80-4143
FDA UDI
Class IActive
Acumed 3006-30016
FDA UDI
Class IIActive
Acumed 5101-0224R
FDA UDI
Class IIActive
Acumed 3004-15011-S
FDA UDI
Class IIActive
Acumed 3006-30024
FDA UDI
Class IIActive
Acumed 01-0011-S
FDA UDI
Class IActive
Acumed 80-2376
FDA UDI
Class IActive
Acumed 3011-43024
FDA UDI
Class IIActive
Acumed COL-3500-S
FDA UDI
Class IIActive
Acumed COL-2100
FDA UDI
Class IIActive
Acumed 80-1167
FDA UDI
Class IActive
Acumed 71-0007
FDA UDI
Class IIActive
Acumed 80-2392
FDA UDI
Class IActive
Acumed FA-CO2738
FDA UDI
Class IIActive
Acumed 3012-15005
FDA UDI
Class IIActive
Acumed 70-0358-S
FDA UDI
Class IIActive
Acumed 80-0035
FDA UDI
Class IActive
Acumed 3005-40030-S
FDA UDI
Class IIActive
Acumed 80-0166
FDA UDI
Class IActive
Acumed CO-F2128
FDA UDI
Class IIActive
Acumed 80-1581
FDA UDI
Class IActive
Acumed PL-ELLSL
FDA UDI
Class IIActive
Acumed 80-0418
FDA UDI
Class IActive
Acumed 30-0901
FDA UDI
Class IIActive
Acumed 3005-30018
FDA UDI
Class IIActive
Acumed 30170340-S
FDA UDI
Class IIActive
Acumed 30-0489
FDA UDI
Class IIActive
Acumed 80-0622
FDA UDI
Class IActive
Acumed 30-0333-S
FDA UDI
Class IIActive
Acumed 3005-65060-S
FDA UDI
Class IIActive
Acumed 80-1634
FDA UDI
Class IActive
Acumed 7007-0109R-S
FDA UDI
Class IIActive
Acumed 70-0104
FDA UDI
Class IIActive
Acumed 5001-0412R-S
FDA UDI
Class IIActive
Acumed 80-2022-S
FDA UDI
Class IActive
Acumed WS-1407ST
FDA UDI
Class IActive
Acumed CO-2726-S
FDA UDI
Class IIActive
Acumed 3013-35042
FDA UDI
Class IIActive
Acumed 30-0765
FDA UDI
Class IIActive
Acumed CO-T2322
FDA UDI
Class IIActive
Acumed 30-0359
FDA UDI
Class IIActive
Acumed SH-4718-S
FDA UDI
Class IActive
Acumed TR-CRA05
FDA UDI
Class IActive
Acumed 3052-35042
FDA UDI
Class IIActive
Acumed 80-2367
FDA UDI
Class IActive
Acumed SH-1018-S
FDA UDI
Class IIActive
Acumed PLT-GLD7
FDA UDI
Class IIActive
Acumed 30-0298-S
FDA UDI
Class IIActive
Acumed 71-0111
FDA UDI
Class IIActive
Acumed 70-0375
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (50)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Dec 19, 2023Z-1218-2024—open, classified

Distribution without Pre-Market Clearance

Nov 27, 2023Z-0618-2024—open, classified

Due to potential breakage during use.

Nov 29, 2022Z-0769-2023—open, classified

Distribution without Pre-Market Clearance

Nov 29, 2022Z-0767-2023—open, classified

Distribution without Pre-Market Clearance

Nov 29, 2022Z-0768-2023—open, classified

Distribution without Pre-Market Clearance

Nov 29, 2022Z-0770-2023—open, classified

Distribution without Pre-Market Clearance

Mar 9, 2022Z-0959-2022—completed

Cannulated Screws 4.0mm x 10mm and 4.0mm x 12mm may not have sufficient axial pullout strength for the indicated use. Remote possibility of resulting in a mal or nonunion of the bone fragments, iatrogenic fracture, joint impingement or damage, or soft tissue damage.

Mar 9, 2022Z-0958-2022—completed

Cannulated Screws 4.0mm x 10mm and 4.0mm x 12mm may not have sufficient axial pullout strength for the indicated use. Remote possibility of resulting in a mal or nonunion of the bone fragments, iatrogenic fracture, joint impingement or damage, or soft tissue damage.

Apr 20, 2017Z-2197-2017—terminated

The firm initiates a voluntary removal and discontinue marketing of Slide-Loc Anatomic Radial Head System based on its performance in the market. The firm received product complaints regarding instrumentation performance, trial product design, and implant dissociations.

Feb 17, 2017Z-1483-2017—terminated

Guide wires sized as .045 X 6 were mis-packaged as .054 X 7 guide wires and those sized as .054 X 7 were mis- packaged as .045 X 6 guide wires. There is a possibility that using the incorrect guide wire size can cause health hazards, such as mal or nonunion, need for revision surgery, and histological response (if wire breaks).

Jan 19, 2017Z-1199-2017—terminated

The 6-hole Pubic Symphysis plate (PN 70-0451) is specified to be made of Commercially Pure Titanium (ASTM F67 - CP Grade 4). However, batch 383813 was manufactured out of Titanium Alloy (Ti-6Al- 4V ELI per ASTM F135 Ti alloy) and was distributed.

Dec 5, 2016Z-1019-2017—terminated

OPT Croutons, part number 65-0210-S, is recalled due to the result of inadequate documentation of the sterilization dose used in production. Product sterilized at the site did not receive the minimum dose required per the new performance qualification.

Mar 26, 2014Z-1515-2014—terminated

Manufacturing of these devices with a grade of stainless steel that is not within specifications.

Mar 26, 2014Z-1516-2014—terminated

Certain lots of Acumed Tension Band Pins are being recalled because the implantable product was manufactured with a grade of stainless steel that is not within specifications.

Mar 7, 2012Z-1357-2012—terminated

The packaging contains the wrong product. It does not contain model HR-0824-S as the package indicates.

Apr 14, 2010Z-1807-2010—terminated

The saw blades may not cut aggressively enough for their intended application therefore creating a risk that the saw could generate excessive heat, which may contribute to bone necrosis and/or non-union.

Aug 21, 2009Z-0073-2010—terminated

Labeling may contain 2 lot numbers and 2 model numbers. It was observed that the box top label (30170060-S, W67391) does not match the two side labels (3010320-S, W67385). The part and patient labeling inside the box match the side labels (30170320-S, W67385).

May 19, 2009Z-1602-2010—terminated

Mix-up of parts - Product labeled cortical bone screw actually contains Acutract fixation screw

Aug 21, 2008Z-1552-2010—terminated

Products improperly handled after cleaning, prior to sanitation and may be contaminated with inorganic material.

Jul 9, 2008Z-1154-2010—terminated

Parts are non-functional. The user is unable to fully pass the fixator pins through the body of the Stableloc assembly as required. The kit may also be missing the set screw.

May 13, 2008Z-0447-2009—terminated

The packages for Modular Shoulder Body Assembly Left (SH-1540L-S) and Modular Shoulder Body Assembly Right (SH-1540R-S) may contain assemblies for the opposite side as indicated.

Mar 28, 2008Z-2140-2008—terminated

Cables of incorrect diameter were used in product assembly, resulting in the sleeve not being able to bind to the cable after crimping.

Feb 14, 2008Z-2127-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2110-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2112-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2131-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2130-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2111-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2128-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2114-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2119-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2129-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2115-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2108-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2126-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2120-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2124-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2121-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2123-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2113-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2125-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2117-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2122-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2118-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2109-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2116-2008—terminated

Product sterility may be compromised.

Feb 14, 2008Z-2132-2008—terminated

Product sterility may be compromised.

Jul 9, 2007Z-2135-2008—terminated

Product mislabeled. The inner sticky labels for the patient identified the product incorrectly as a Cortical screw (non-locking). The product package was labeled correctly.

Jun 29, 2007Z-2153-2008—terminated

Plates are incorrectly laser marked. The PL-DR50L plates are incorrectly laser marked with PL-DR70L.

Dec 27, 2005Z-2155-2008—terminated

Package of 3.5mm X 32.5mm cortical screw may contain 3.5mm X 22.5mm cortical screw.