ORTHO DEVELOPMENT CORP.

US

Last updated September 17, 2026

What ORTHO DEVELOPMENT CORP. makes

Ortho Development Corp. manufactures orthopedic implants including tibial inserts, acetabular shells, knee and hip prostheses (both uncoated and coated, modular and fixed), spinal bone screws, polymeric spinal interbody fusion cages, and knee arthroplasty wedges. Specific device examples include the Pagoda, Balance Knee Revision System, BKS TriMax PS Plus, Trivicta, Escalade Acetabular System, BKS E-Vitalize, and BKS® Uni.

All listed devices are classified as Class II medical devices and are registered in the FDA’s Unique Device Identification (fda_udi) system. The company is based in the United States.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What does Ortho Development Corp. make?

Ortho Development Corp. manufactures orthopedic implants such as tibial inserts, acetabular shells, knee and hip prostheses (both uncoated and coated, modular and fixed), spinal bone screws, polymeric spinal interbody fusion cages, and knee arthroplasty wedges. Specific examples include the Pagoda, Balance Knee Revision System, BKS TriMax PS Plus, Trivicta, Escalade Acetabular System, BKS E-Vitalize, and BKS® Uni.

Where is Ortho Development Corp. based?

Ortho Development Corp. is based in the United States, as stated in the provided device data under the COUNTRY field.

Which registries list Ortho Development Corp.'s devices?

Ortho Development Corp.'s devices are listed in the FDA’s Unique Device Identification (fda_udi) system, as indicated in the LISTED IN field of the device data.

How are Ortho Development Corp.'s devices classified?

All devices manufactured by Ortho Development Corp. are classified as Class II medical devices, as explicitly stated in the DEVICE CLASSES field of the provided data.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
12187 SOUTH BUSINESS PARK DR., DRAPER, UT, 84020
Website
—
LinkedIn
—
Facebook
—
Email
—
Phone
—
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
1000143502
DUNS Number
—

Catalogue (3843)

Page 65 of 77
DeviceModel / ReferenceRegistriesClassStatus
Pagoda 752-5550-12
FDA UDI
Class IIUnknown
BKS® Uni 763-1112
FDA UDI
Class IIActive
Balanced Knee Revision System 563-2216
FDA UDI
Class IIActive
Balanced Knee System 163-1311
FDA UDI
Class IIActive
Ibis 752-6530-21A
FDA UDI
Class IIActive
Balanced Knee Revision System 563-2208
FDA UDI
Class IIActive
Pagoda 752-5540-12
FDA UDI
Class IIUnknown
Vusion OS 551-7410
FDA UDI
Class IIUnknown
Vusion TS 551-1013
FDA UDI
Class IIUnknown
Balanced Knee Revision System 566-1322
FDA UDI
Class IIActive
BKS E-Vitalize 166-7714
FDA UDI
Class IIActive
BKS E-Vitalize 166-7213
FDA UDI
Class IIActive
Ovation Hip Stem 101-1009
FDA UDI
Class IIActive
Balanced Knee System 163-2614
FDA UDI
Class IIActive
Balanced Knee System 161-3602A
FDA UDI
Class IIActive
Vusion CS Plus 159-1605-00A
FDA UDI
Class IIActive
Integrated Spine System 158-1050
FDA UDI
Class IIUnknown
BKS TriMax 165-1701
FDA UDI
Class IIActive
BKS® Uni 763-7091
FDA UDI
Class IIActive
Ibis 752-7550-26
FDA UDI
Class IIUnknown
BKS E-Vitalize 166-7514
FDA UDI
Class IIActive
BKS E-Vitalize 166-7316
FDA UDI
Class IIActive
Balanced Knee System 163-1212
FDA UDI
Class IIActive
Balanced Knee Revision System 569-1911
FDA UDI
Class IIActive
Pivot Bipolar 133-2258
FDA UDI
Class IIActive
Balanced Knee System 163-1512
FDA UDI
Class IIActive
Balanced Knee System 161-3202
FDA UDI
Class IIActive
Balanced Knee Revision System 563-2424
FDA UDI
Class IIActive
Vusion PS 551-2111
FDA UDI
Class IIUnknown
Vusion OS 551-6409
FDA UDI
Class IIUnknown
Pisces Spinal System 753-8560-20
FDA UDI
Class IIActive
Entrada Hip Stem 510-1018
FDA UDI
Class IIActive
Balanced Knee System 161-1506A
FDA UDI
Class IIActive
Pagoda 752-4540-31A
FDA UDI
Class IIActive
Ovation 101-0412
FDA UDI
Class IIActive
BKS® Uni 763-3081A
FDA UDI
Class IIActive
Legend 174-2858
FDA UDI
Class IIActive
Vusion OS 551-6416
FDA UDI
Class IIUnknown
Vusion PS 551-5107
FDA UDI
Class IIUnknown
Balanced Knee System 161-4701
FDA UDI
Class IIActive
BKS E-Vitalize 166-7210
FDA UDI
Class IIActive
Balanced Knee System 161-3701A
FDA UDI
Class IIActive
Ovation Tribute Hip Stem 101-0304
FDA UDI
Class IIActive
Balanced Knee Revision System 561-5252
FDA UDI
Class IIActive
Legend Acetabular Shell 170-0562/A
FDA UDI
Class IIActive
Ibis Xl 752-1090-57A
FDA UDI
Class IIActive
BKS E-Vitalize 166-5413
FDA UDI
Class IIActive
Escalade Acetabular System 170-0340
FDA UDI
Class IIActive
Balance Knee Revision System 566-2208
FDA UDI
Class IIActive
Vusion OS 551-7210
FDA UDI
Class IIUnknown

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (28)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

There are 28 recall records for Ortho Development Corp., with the earliest initiated on December 26, 2002, and the most recent on May 30, 2019. The statuses of these recalls include open, classified, and terminated. The reasons given for the recalls include erroneous lot numbers, potential mechanical issues such as restricted movement or breakage of components, incorrect assembly, improper sealing of foil pouches, mislabeling, and manufacturing defects affecting fit or function.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
May 30, 2019Z-1903-2020—open, classified

The locking mechanism of the tibial tray exhibited a manufacturing defect in which a uniform ridge was cut along the inner wall of the "T" and "Y" junctions, which may cause resistance when the Tibial Insert was being assembled.

May 30, 2019Z-1904-2020—open, classified

The locking mechanism of the tibial tray exhibited a manufacturing defect in which a uniform ridge was cut along the inner wall of the "T" and "Y" junctions, which may cause resistance when the Tibial Insert was being assembled.

Jul 11, 2014Z-2257-2014—terminated

Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increases the risk that the material properties of the implant would be substantially degraded due to oxidation.

Jul 11, 2014Z-2256-2014—terminated

Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increases the risk that the material properties of the implant would be substantially degraded due to oxidation.

Jul 11, 2014Z-2255-2014—terminated

Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increases the risk that the material properties of the implant would be substantially degraded due to oxidation.

Jul 11, 2014Z-2253-2014—terminated

Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increases the risk that the material properties of the implant would be substantially degraded due to oxidation.

Jul 11, 2014Z-2254-2014—terminated

Ortho Development is recalling various Pivot Bipolar Cup, Patella, PS Tibial Insert, UC Tibila Insert, and CK Tibil Insert because the foil pouches did not properly seal, allowing air to seep back into the pouch after sealing which increases the risk that the material properties of the implant would be substantially degraded due to oxidation.

Apr 1, 2014Z-1610-2014—terminated

A femoral component containing pegs was found in a box for the pegless version.

Dec 19, 2011Z-0740-2012—terminated

Tip of hex-head screwdriver may break off during use in hip replacement procedure.

May 10, 2011Z-2602-2011—terminated

Tests on PVC packaging material resulted in alert levels for cytotoxicity.

May 10, 2011Z-2603-2011—terminated

Tests on PVC packaging material resulted in alert levels for cytotoxicity.

Jan 11, 2011Z-1673-2011—terminated

Component of total hip arthroplasty may break during surgical procedure.

Jan 11, 2011Z-1670-2011—terminated

Component of total hip arthroplasty may break during surgical procedure.

Jan 11, 2011Z-1671-2011—terminated

Component of total hip arthroplasty may break during surgical procedure.

Jan 11, 2011Z-1672-2011—terminated

Component of total hip arthroplasty may break during surgical procedure.

Jan 7, 2011Z-1740-2011—terminated

Components of a replacement knee system could be mislabeled.

Jan 7, 2011Z-1741-2011—terminated

Components of a replacement knee system could be mislabeled.

Jan 7, 2011Z-1742-2011—terminated

Components of a replacement knee system could be mislabeled.

Jul 28, 2010Z-0315-2011—terminated

The hip stem did not fit the distal centralizer because the hole was not drilled with the appropriate taper.

May 29, 2009Z-1993-2009—terminated

Erroneous lot number on 3 of 28 units of Balanced Knee System. Three units from Lot Number 0055245 were mixed in with the recalled lot (0054891).

Apr 29, 2009Z-0086-2010—terminated

A Pivot BiPolar Head, the femoral head in a hip prosthesis, might not move freely after assembly due a stacking up of manufacturing tolerances.

Mar 19, 2009Z-1229-2010—terminated

A component of knee prosthesis was assembled incorrectly.

Mar 19, 2009Z-1228-2010—terminated

A component of knee prosthesis was assembled incorrectly.

Sep 15, 2003Z-0042-04—terminated

The guide pin which rotationally constrains the tibial punch within the punch guide, may fall out.

Dec 26, 2002Z-0567-03—terminated

Cleaning agent residue from packaging material was adhering to implantable hip stems.

Dec 26, 2002Z-0568-03—terminated

Cleaning agent residue from packaging material was adhering to implantable hip stems.

Dec 26, 2002Z-0566-03—terminated

Cleaning agent residue from packaging material was adhering to implantable hip stems.

Dec 26, 2002Z-0569-03—terminated

Cleaning agent residue from packaging material was adhering to implantable hip stems.