What Ferno-Washington, Inc. makes

Ferno-Washington, Inc. manufactures manual and electrohydraulic ambulance stretchers, including models designed for patient transport in emergency and medical settings. Their product line also includes stair chairs and cot-style devices, some of which are equipped for specialized transport, such as neonatal incubators. Additional offerings include modular transporter systems for moving patients between care environments.

The company’s devices are classified under FDA categories Class I and Class II, with regulatory authorisation through 510(k) clearances and inclusion in the FDA’s Unique Device Identifier (UDI) database. These products are listed under U.S. regulatory frameworks and are intended for use within the American healthcare system.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Information

Country
US
Address
70 WEIL WAY, Wilmington, OH, 45177
Website
ww.ferno.com

This website had an invalid or expired security certificate when we last checked. Last checked 2026-09-18.

LinkedIn
—
Facebook
—
Email
—
Phone
—
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
1523574
DUNS Number
—

Catalogue (150)

Page 3 of 3
DeviceModel / ReferenceRegistriesClassStatus
35A-IT Incubator Transporter 0063117
FDA UDI
Class IIUnknown
Mondial® Transporter 0054227
FDA UDI
Class IIActive
Mondial® Monobloc 0054248
FDA UDI
Class IIUnknown
Mondial® Transporter 0054219
FDA UDI
Class IIActive
PowerFlexx® 0015654
FDA UDI
Class IIUnknown
35A-NM Ambulance Cot 0015612
FDA UDI
Class IIUnknown
Power X1 0015807
FDA UDI
Class IIActive
35A Ambulance Cot 0015610
FDA UDI
Class IIActive
35X ProFlexx® 0015700
FDA UDI
Class IIActive
iNX 0015814
FDA UDI
Class IIUnknown
93H ProFlexx® 0015757
FDA UDI
Class IIUnknown
Mondial® Transporter 0054223
FDA UDI
Class IIUnknown
5126 Cot 0054158
FDA UDI
Class IIUnknown
4052 Transporter 0054100
FDA UDI
Class IIUnknown
28 MDA Ferno Flex Roll In Chair Cot 0015779
FDA UDI
Class IIUnknown
35A-ITA Incubator Transporter 0063091
FDA UDI
Class IIActive
York 4 Trolley 0054010
FDA UDI
Class IIUnknown
30 NM Cot 0013005
FDA UDI
Class IIActive
PowerFlexx® 0054214
FDA UDI
Class IIUnknown
93H ProFlexx® 0015763
FDA UDI
Class IIUnknown
93H ProFlexx® 0015758
FDA UDI
Class IIUnknown
iNX 0015812
FDA UDI
Class IIUnknown
iN∫X® 0015803
FDA UDI
Class IIActive
93H-J ProFlexx® 0054277
FDA UDI
Class IIUnknown
28A-1 Roll In Cot 0163281
FDA UDI
Class IIActive
35X-IT ProFlexx® Incubator Transporter 0163276
FDA UDI
Class IIUnknown
Mondial® Transporter 0054239
FDA UDI
Class IIActive
28Z ProFlexx® Chair Cot 0012813
FDA UDI
Class IIUnknown
Mondial® Monobloc 0054267
FDA UDI
Class IIUnknown
25 Ambulance Cot 0054211
FDA UDI
Class IIUnknown
Transcend Chair Series 0731402
FDA UDI
Class IActive
35X-NM ProFlexx® 0015789
FDA UDI
Class IIUnknown
Mondial® Monobloc 0054268
FDA UDI
Class IIUnknown
26 Cot 0012601
FDA UDI
Class IIUnknown
26 AS Cot 0054163
FDA UDI
Class IIUnknown
28 Ferno Flex Roll In Chair Cot 0012801
FDA UDI
Class IIActive
35A+ Ambulance Cot 0015596
FDA UDI
Class IIUnknown
Mondial® Transporter 0054236
FDA UDI
Class IIUnknown
35X-ST ProFlexx® 0015794
FDA UDI
Class IIUnknown
Pro 28z 0012826
FDA UDI
Class IIActive
28 Aero Incubator Transporter 0063100
FDA UDI
Class IIActive
PowerFlexx® 0015800
FDA UDI
Class IIUnknown
35X ProFlexx® 0015710
FDA UDI
Class IIActive
Mondial® Transporter 0054231
FDA UDI
Class IIActive
Mondial® Monobloc 0054257
FDA UDI
Class IIUnknown
Ferno Healthcare Recline-A-Bath 2 K980033
FDA 510(k)
Class IIActive
Model 668, Traction Splint, Adult K864765
FDA 510(k)
Class IActive
Ferno Washington Incubator Transporter, Mod. 35-It K932417
FDA 510(k)
Class IIActive
Model 35-B All Level Cot K864269
FDA 510(k)
Class IIActive
Ez Load Model 30, All Level Cot K862441
FDA 510(k)
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (12)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Ferno-Washington, Inc. has 12 recall records initiated between March 28, 2003, and September 11, 2025, with statuses including open, classified, and terminated. The reasons cited involve manufacturing defects such as incorrect labeling on packaging for traction splint straps, improperly installed or incorrect hardware components (e.g., set screws, nuts, castings), potential structural failures (e.g., wheel castor loosening, stretcher folding, metal fatigue in legs), and design issues (e.g., hole elongation in telescoping load frames, improperly seated shank pins). Some records reference supplier errors in labeling, while others involve defects discovered during production or reported by users.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Sep 11, 2025Z-0133-2026—open, classified

The fastening post hardware could loosen allowing the fastening post to detach from the cot

Oct 7, 2022Z-0184-2023—open, classified

Batteries could become unstable when not properly maintained and/or subjected to repeated drops, power washing directly into battery contacts or abuse, may result in a fire and/or injury

Mar 8, 2017Z-1827-2017—terminated

The recall was initiated as a result of the detection of an incorrect nut used in manufacturing.

Mar 10, 2016Z-1603-2016—terminated

On March 9, 2016, the firm was contacted regarding the possibility of incorrect labeling on the outside poly- bag of the traction splint straps. The firm investigated and determined its supplier had labeled the outside packaging for the pediatric and adult traction splints straps incorrectly. The packaging labeled Adult contained a pediatric splint strap and the packaging labeled pediatric cont

Mar 10, 2016Z-1604-2016—terminated

On March 9, 2016, the firm was contacted regarding the possibility of incorrect labeling on the outside poly- bag of the traction splint straps. The firm investigated and determined its supplier had labeled the outside packaging for the pediatric and adult traction splints straps incorrectly. The packaging labeled Adult contained a pediatric splint strap and the packaging labeled Pediatric conta

Aug 3, 2015Z-2826-2015—terminated

Hole elongation in the telescoping load frame channel. A hole elongation could affect the ability of the retention pin to stay seated which is necessary to preclude movement of the telescoping load frame.

May 1, 2015Z-2461-2015—terminated

The firm discovered an improperly installed set screw in one caster arm assembly on a unit in production. The screw assists in preventing the bearing cup on the caster assembly from backing out of the caster arm during use.

Dec 3, 2014Z-0995-2015—terminated

The wheel castor assemblies may be loosening on the stretchers.

Sep 3, 2008Z-2465-2008—terminated

The Ferno Model 35-X PROFlexx legs could experience metal fatigue and possibly fracture after one to two years of use based on the usage and method of operation.

Apr 29, 2008Z-1859-2008—terminated

A component defect was found in corner castings of the firm's wheeled ambulance stretchers. Some corner castings on the stretchers were found to be over-sized. Using an over-sized cone-shaped hole corner casting with an improperly seated shank pin could put undue stress on the top screw, possibly causing the screw securing a wheel to become loose or break and the wheel to detach from the stretcher

Mar 28, 2003Z-0202-06—terminated

The firm received complaints of the stretchers folding. A fold is when the stretcher lowers on its own to either the next position, or any of the other seven postions of the stretcher.

Mar 28, 2003Z-0201-06—terminated

The firm received complaints of the stretchers folding. A fold is when the stretcher lowers on its own to either the next position, or any of the other seven postions of the stretcher.