Fischer Imaging Corp.
United StatesFDA applicant, unverified
- Devices
- 69
- FDA recalls
- 11
At a glance
Market reach
- United States
- FDA recalls
Catalogue
Search and filter all 69 devicesShowing 1-50 of 69
FDA recalls
2006
- 27 Mar 2006 Z-0757-06 Unclassified (pre-2012) Terminated Software upgrade to preclude lost images during mammography procedure.
Full distribution text
- 27 Mar 2006 Z-0757-06 Unclassified (pre-2012) Terminated Software upgrade to preclude lost images during mammography procedure.
2005
- 28 Apr 2005 Z-1524-05 Unclassified (pre-2012) Terminated Belt driving the Image Intensifier may break, causing the Intensifier to slip down, possibly causing injury to patient.
Full distribution text
- 28 Apr 2005 Z-1525-05 Unclassified (pre-2012) Terminated Belt driving the Image Intensifier may break, causing the Intensifier to slip down, possibly causing injury to patient.
Full distribution text
- 28 Apr 2005 Z-1526-05 Unclassified (pre-2012) Terminated Belt driving the Image Intensifier may break, causing the Intensifier to slip down, possibly causing injury to patient.
Full distribution text
- 28 Apr 2005 Z-1527-05 Unclassified (pre-2012) Terminated Belt driving the Image Intensifier may break, causing the Intensifier to slip down, possibly causing injury to patient.
Full distribution text
- 13 Jan 2005 Z-0713-05 Unclassified (pre-2012) Terminated Possibility that after a loss of power or brown-out, the device may transmit unintended stimulation to patients.
Full distribution text
- 28 Apr 2005 Z-1524-05 Unclassified (pre-2012) Terminated Belt driving the Image Intensifier may break, causing the Intensifier to slip down, possibly causing injury to patient.
2004
- 30 Sep 2004 Z-0787-05 Unclassified (pre-2012) Terminated Some VersaRad Systems have a faulty weld that may result in oil leakage.
Full distribution text
- 9 Jul 2004 Z-0379-05 Unclassified (pre-2012) Terminated X-ray tube actuator shaft may fail, allowing the mechanism to drop without warning.
Full distribution text
- 21 May 2004 Z-1094-04 Unclassified (pre-2012) Terminated Existing software may allow Image data to be truncated in the margin of the breast on processed patient images.
- 23 Apr 2004 Z-0974-04 Unclassified (pre-2012) Terminated If two of the four T-nuts that connect the transverse rail to the ceiling rail fail, the 'U' arm and transverse rails could fall and cause serious injury.
Full distribution text
- 30 Sep 2004 Z-0787-05 Unclassified (pre-2012) Terminated Some VersaRad Systems have a faulty weld that may result in oil leakage.
Show all 11 recalls
2004
- 12 Apr 2004 Z-0939-04 Unclassified (pre-2012) Terminated X-ray tube may overheat after high usage because of mis-wired thermal switch circuit.
Frequently asked questions
How many devices does Fischer Imaging Corp. have in the registry?
The registry currently lists 69 devices for Fischer Imaging Corp.. Devices recorded under merged duplicate company entries are counted once.
Which registries list Fischer Imaging Corp.'s devices?
Among its 50 most recently registered devices, Fischer Imaging Corp. has devices listed in FDA 510(k) (50 devices).
What risk classes do Fischer Imaging Corp.'s devices fall under?
Among its 50 most recently registered devices, the classes recorded for Fischer Imaging Corp.'s devices are Class I and Class II. Each device page shows its own class and authorisation.
Are there FDA recall records for Fischer Imaging Corp.?
FDA recall records list 11 recalls initiated by Fischer Imaging Corp., the most recent initiated on 2006-03-27. A recall is often a precaution started by the manufacturer; the records say nothing about the company's overall record.
What are the newest devices from Fischer Imaging Corp. in the registry?
The most recently registered devices listed for Fischer Imaging Corp. include RADIOGRAPHIC FLOOR MOUNTED TUBESTAND FM 60, RMS 180, ELITE R 90/15 and FVP-1000 FAMILY AND FVP-1000D FAMILY.