Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

INTERVENTIONAL SPINE, INC

US

Last updated May 24, 2026

What INTERVENTIONAL SPINE, INC makes

The company manufactures orthopaedic spinal fixation devices, including internal fixation systems, bone screws, and metallic spinal interbody and fusion cages designed for surgical spinal stabilization. Their portfolio also includes reusable surgical tools such as rotary handpieces, implant drivers, and procedure kits, as well as bone-nailing compression screws and drill bits for spinal procedures. Expandable interbody implants and compression devices are among the specialized products used in spinal fusion surgeries.

These devices are regulated under the FDA’s classification system, with products falling into Class I, Class II, and Unclassified (U) categories. They are listed in the FDA’s 510(k) and Unique Device Identifier (UDI) registries, ensuring compliance with U.S. medical device regulations. The company operates within the United States, adhering to domestic regulatory requirements for spinal orthopaedic hardware.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What types of medical devices does Interventional Spine, Inc. manufacture?

Interventional Spine, Inc. specializes in orthopaedic spinal fixation devices. Their portfolio includes internal orthopaedic fixation system implantation kits, bone screws for spinal stabilization, metallic spinal interbody and fusion cages, and reusable surgical tools like rotary handpieces and implant drivers. They also produce specialized items such as expandable interbody implants, compression screws, and drill bits, all designed for spinal stabilization and fusion surgeries.

Where is Interventional Spine, Inc. based, and how does that affect its regulatory compliance?

Interventional Spine, Inc. is based in the United States, which means its devices are subject to U.S. regulatory requirements, specifically those governed by the FDA. Since the company’s products fall under Class I, Class II, and Unclassified (U) categories, they must comply with FDA regulations applicable to those classifications, including premarket submissions like 510(k) clearances for Class II devices.

Which regulatory registries list Interventional Spine, Inc.’s devices?

Interventional Spine, Inc.’s devices are listed in the FDA’s 510(k) and Unique Device Identifier (UDI) registries. The 510(k) registry documents premarket submissions for Class II devices, while the UDI system ensures standardized identification and traceability of medical devices in the U.S., helping track compliance and post-market surveillance.

How are Interventional Spine, Inc.’s devices classified under FDA regulations?

Interventional Spine, Inc.’s devices are classified under three FDA categories: Class I (generally low-risk devices with minimal regulation), Class II (moderate-risk devices requiring special controls like 510(k) clearance), and Unclassified (U) devices, which may require additional evaluation depending on their risk profile. Classification determines the regulatory pathway, with higher-risk devices requiring more stringent premarket review.

What kinds of spinal fixation solutions does Interventional Spine, Inc. provide, and how do they differ?

The company offers a range of spinal fixation solutions, including permanent implants like metallic interbody and fusion cages (used for structural support in fusion surgeries), bone screws for internal fixation, and reusable surgical tools like rotary handpieces and drivers. Expandable interbody implants, such as the Opticage, provide adjustable spacing during surgery, while compression devices like the BONE-LOK MVP stabilize bone fragments. These vary in function—some are implants for long-term support, while others are tools for surgical precision.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
US
Address
—
LinkedIn
—
Facebook
—
Phone
800-497-0484
PRRC Contact
—
EUDAMED SRN
—
FDA FEI Number
—
DUNS Number
017663522

Catalogue (303)

Page 1 of 7
DeviceModel / ReferenceRegistriesClassStatus
BONE-LOK MVP Cortical-Cancellous Compression Device TMCD-35-2530S
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9180-17
FDA UDI
Class IIUnknown
Opticage Expandable Interbody Implant 9080-12
FDA UDI
Class IIActive
Ratcheting T-Handle with 1/4" Square Cannulated Quick Connect 6054
FDA UDI
Class IActive
Opticage Expandable Interbody Implant 9080-05
FDA UDI
Class IIActive
5mm Angled Curette 6189-01
FDA UDI
Class IUnknown
Distractor Shaver, 5x7mm 6192-01
FDA UDI
Class IUnknown
Trephine 6182-00
FDA UDI
Class IUnknown
Countersink 6093
FDA UDI
Class IActive
Distractor Shaver, 5x8mm 6192-02
FDA UDI
Class IUnknown
Distractor Shaver, 5x9mm 6192-03
FDA UDI
Class IUnknown
Straight Cannula Assembly 6171-00
FDA UDI
Class IUnknown
Opticage Expandable Interbody Implant 9080-21
FDA UDI
Class IIActive
3.2mm Guide Wire 6047
FDA UDI
Class IActive
PERPOS PLS Compression Tool Cassette 6129-00
FDA UDI
Class IUnknown
Three Prong Driver 6015
FDA UDI
Class IActive
Opticage Expandable Interbody Implant 9180-08
FDA UDI
Class IIUnknown
Perpos Pls System 9045-00
FDA UDI
Class IUnknown
Opticage Expandable Interbody Implant 9080-17
FDA UDI
Class IIActive
7.3mm Short Cortex Drill 6045
FDA UDI
Class IActive
Pin Cutter 6019
FDA UDI
Class IActive
Torque Limiting Handle 6214-00
FDA UDI
Class IUnknown
3.8mm CS Facet Compression Device CS-38-2530
FDA UDI
UActive
Up Rongeur, 4 x 10mm 6190-02
FDA UDI
Class IUnknown
Opticage Expandable Interbody Implant 9070-19
FDA UDI
Class IIActive
8 Degree Lordotic, Opticage Expandable Interbody Implant 9101-06
FDA UDI
Class IIUnknown
Opticage Expandable Interbody Implant 9080-00
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9080-18
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9070-21
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9080-02
FDA UDI
Class IIActive
PERPOS FCD-2 System 9061-00
FDA UDI
Class IActive
Opticage Expandable Interbody Implant 9070-11
FDA UDI
Class IIActive
8 Degree Lordotic, Opticage Expandable Interbody Implant 9101-08
FDA UDI
Class IIUnknown
3.5/4.5mm Pull Pin Extractor 6037
FDA UDI
Class IActive
G3 Graft Plunger 6217-00
FDA UDI
Class IActive
8 Degree Lordotic, Opticage Expandable Interbody Implant 9101-13
FDA UDI
Class IIUnknown
7.3mm BONE-LOK Implant TLCD-73-90100S
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9070-18
FDA UDI
Class IIActive
Opticage Expandable Interbody Implant 9070-06
FDA UDI
Class IIActive
3.2mm Cleaning Brush 6056
FDA UDI
Class IActive
4.5mm BONE-LOK PLS Implant LSW-45-4555
FDA UDI
UActive
HP Instrument Tray Ship Assembly 9020
FDA UDI
Class IActive
Opticage Expandable Interbody Implant 9180-09
FDA UDI
Class IIUnknown
PerX360 System, Tray Pin Mat 6207-00
FDA UDI
Class IUnknown
8 Degree Lordotic, Opticage Expandable Interbody Implant 9101-05
FDA UDI
Class IIUnknown
Flexible Compression Tool 6124-00
FDA UDI
Class IUnknown
PERPOS FCD-2 System 9063-01
FDA UDI
UActive
2.7mm Drill 6002
FDA UDI
Class IActive
Access Needle 9053
FDA UDI
Class IActive
Opticage Expandable Interbody Implant 9080-09
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (10)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Interventional Spine, Inc. has ten recall records initiated between February 22, 2008, and November 22, 2016, all marked as terminated. The recalls involved issues with device components, including drivers potentially containing burrs, K-wires with incorrect tip diameters, separation risks during implantation, disengaging pull pins, and drill breakage during use. Each recall cited specific mechanical or functional defects that could affect procedural performance or device functionality.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Nov 22, 2016Z-0941-2017—terminated

During implantation, the proximal end of the device could separate if the angle between the device and insertion instrument is too steep. This separation will prevent the device from expanding.

Mar 23, 2011Z-2719-2011—terminated

This recall has been initiated due to K-wires with a distal tip diameter that may be greater than specified causing an interference fit with the canulated screw. Removing the K-wire during a procedure may dislocate the implant resulting in the implant loosening or being pulled out or position. Use of this product may result in a delay of the surgical procedure and/or pull-out of the facet screw

Mar 23, 2011Z-2718-2011—terminated

This recall has been initiated due to K-wires with a distal tip diameter that may be greater than specified causing an interference fit with the canulated screw. Removing the K-wire during a procedure may dislocate the implant resulting in the implant loosening or being pulled out or position. Use of this product may result in a delay of the surgical procedure and/or pull-out of the facet screw

Mar 15, 2011Z-3033-2011—terminated

This recall has been initiated due to Pull Pins that may disengage from the Facet Screw during the compression step, requiring that compression be completed with a device driver rather than the compression tool. Use of this product may result in less than optimal compression leading to pseudoarthrosis, non-union or facet pain.

Mar 15, 2011Z-3034-2011—terminated

This recall has been initiated due to Pull Pins that may disengage from the Facet Screw during the compression step, requiring that compression be completed with a device driver rather than the compression tool. Use of this product may result in less than optimal compression leading to pseudoarthrosis, non-union or facet pain.

Feb 3, 2011Z-0046-2012—terminated

This recall has been initiated due to drivers that may contain a burr in the distal tip preventing full seating of the driver onto the head of the facet screw, resulting in difficulty screwing the facet screw into the bone. Use of this product may result in a delay of the surgical procedure

Feb 3, 2011Z-0047-2012—terminated

This recall has been initiated due to drivers that may contain a burr in the distal tip preventing full seating of the driver onto the head of the facet screw, resulting in difficulty screwing the facet screw into the bone. Use of this product may result in a delay of the surgical procedure

Feb 3, 2011Z-0045-2012—terminated

This recall has been initiated due to drivers that may contain a burr in the distal tip preventing full seating of the driver onto the head of the facet screw, resulting in difficulty screwing the facet screw into the bone. Use of this product may result in a delay of the surgical procedure

Feb 22, 2008Z-0420-2012—terminated

The recall was intiated because Interventional Spine has confirmed that the PERPOS 2-in-1 Drill (6070) manufactured by a contract manufacturer for Interventional Spine, Inc., may break during use.

Feb 22, 2008Z-0419-2012—terminated

The recall was intiated because Interventional Spine has confirmed that the PERPOS 2-in-1 Drill (6070) manufactured by a contract manufacturer for Interventional Spine, Inc., may break during use.